Measurement of indoor formaldehyde concentrations with a passive sampler

被引:52
|
作者
Gillett, RW [1 ]
Kreibich, H
Ayers, GP
机构
[1] CSIRO, Aspendale, Vic 3195, Australia
[2] Tech Univ Berlin, Berlin, Germany
关键词
D O I
10.1021/es990929n
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
An existing Ferm type passive sampler technique has been further developed to measure concentrations of formaldehyde gas in indoor air. Formaldehyde forms a derivative after reaction with a filter coated with 2,4-dinitrophenylhydrazine (2,4-DNPH). The formaldehyde 2,4-dinitrophenylhydrazine derivative (formaldehyde-2,4-DNPH) is extracted from the filter, and the concentration is determined by high performance liquid chromatography. The technique has been Validated against an active sampling method, and the agreement is close when the appropriate laminar boundary layer depth is applied to the passive measurement. For this technique an exposure period of 3 days is equivalent to a limit of detection of formaldehyde of 3.4 ppbv and a limit of quantification of 7.6 ppbv. To test the performance of the passive samplers ambient formaldehyde measurements were carried out inside homes and in a range of workplace environments.
引用
收藏
页码:2051 / 2056
页数:6
相关论文
共 50 条
  • [21] REDUCING INDOOR AIR FORMALDEHYDE CONCENTRATIONS
    MEYER, B
    HERMANNS, K
    JOURNAL OF THE AIR POLLUTION CONTROL ASSOCIATION, 1985, 35 (08): : 816 - 821
  • [22] Reducing indoor air formaldehyde concentrations
    Meyer, B.
    Hermanns, K.
    1600, (35):
  • [23] Outdoor formaldehyde matters and substantially impacts indoor formaldehyde concentrations
    Liu, Cong
    Miao, Xinyao
    Li, Jingguang
    BUILDING AND ENVIRONMENT, 2019, 158 (145-150) : 145 - 150
  • [24] Analysis of ambient concentrations of organic vapors with a passive sampler
    Shields, H.C.
    Weschler, C.J.
    1600, (37):
  • [25] Passive aerosol sampler for particle concentrations and size distributions
    Whitehead, Todd
    Leith, David
    JOURNAL OF ENVIRONMENTAL MONITORING, 2008, 10 (03): : 331 - 335
  • [26] ANALYSIS OF AMBIENT CONCENTRATIONS OF ORGANIC VAPORS WITH A PASSIVE SAMPLER
    SHIELDS, HC
    WESCHLER, CJ
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1987, 193 : 62 - ENVR
  • [27] ANALYSIS OF AMBIENT CONCENTRATIONS OF ORGANIC VAPORS WITH A PASSIVE SAMPLER
    SHIELDS, HC
    WESCHLER, CJ
    JAPCA-THE INTERNATIONAL JOURNAL OF AIR POLLUTION CONTROL AND HAZARDOUS WASTE MANAGEMENT, 1987, 37 (09): : 1039 - 1045
  • [29] Validation of a passive flux sampler for on-site measurement of formaldehyde emission rates from building and furnishing materials
    Blondel, Alodie
    Plaisance, Herve
    ANALYTICAL METHODS, 2010, 2 (12) : 2032 - 2038
  • [30] A passive sampler for ambient gaseous oxidized mercury concentrations
    Lyman, Seth N.
    Gustin, Mae S.
    Prestbo, Eric M.
    ATMOSPHERIC ENVIRONMENT, 2010, 44 (02) : 246 - 252