Validation of a passive flux sampler for on-site measurement of formaldehyde emission rates from building and furnishing materials

被引:15
|
作者
Blondel, Alodie [1 ,2 ]
Plaisance, Herve [1 ,2 ]
机构
[1] Univ Lille Nord France, F-59000 Lille, France
[2] Ecole Mines Douai, Dept Chim & Environm, F-59508 Douai, France
关键词
CARBONYL-COMPOUNDS; INDOOR AIR; FIELD;
D O I
10.1039/c0ay00416b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A diffusive sampling device was developed for screening indoor sources of formaldehyde and determining the emission rates of these sources on-site. It consists of a glass Petri dish containing a quartz filter coated with 2,4-dinitrophenylhydrazine (DNPH) which is placed on the tested material for sampling. Formaldehyde emitted from the material diffuses through the air column inside the sampler and is collected onto the DNPH filter. The formaldehyde emission rate is determined from the mass collected by the sampler. The dependence of the sampled formaldehyde amount on the diffusion length inside the sampler was examined and led us to select a length of 20 mm for which the diffusion in the air layer controls the mass transfer from the material to the sampling surface (filter). A linear relationship with a high correlation (r(2) = 0.97) was obtained between the mass collected by the passive flux sampler and the emission rates measured by a standard chamber method, analysing a large series of indoor materials with the two methods in parallel. Neither the sampling time (ranging from 4 to 8 h) nor the temperature (from 23 to 35 degrees C) was observed to influence the sampler performance. Furthermore, the detection limit attained 1.2 mu g m(-2) h(-1) for a 6h-sampling time and a satisfying precision of replicate measurements (relative standard deviation of 7.8% on average) is adequate for monitoring the emission rates of primary sources contributing to formaldehyde indoor concentrations.
引用
收藏
页码:2032 / 2038
页数:7
相关论文
共 36 条
  • [1] Passive flux sampler for measurement of formaldehyde emission rates
    Shinohara, Naohide
    Fujii, Minoru
    Yamasaki, Akihiro
    Yanagisawa, Yukio
    ATMOSPHERIC ENVIRONMENT, 2007, 41 (19) : 4018 - 4028
  • [2] On-site passive flux sampler measurement of emission rates of carbonyls and VOCs from multiple indoor sources
    Shinohara, Naohide
    Kai, Yuya
    Mizukoshi, Atsushi
    Fujii, Minoru
    Kumagai, Kazukiyo
    Okuizumi, Yumiko
    Jona, Miki
    Yanagisawa, Yukio
    BUILDING AND ENVIRONMENT, 2009, 44 (05) : 859 - 863
  • [3] A study on emission of phthalate esters from plastic materials using a passive flux sampler
    Fujii, M
    Shinohara, N
    Lim, A
    Otake, T
    Kumagai, K
    Yanagisawa, Y
    ATMOSPHERIC ENVIRONMENT, 2003, 37 (39-40) : 5495 - 5504
  • [4] Passive flux sampler measurements of emission rates of phthalates from poly(vinyl chloride) sheets
    Noguchi, Miyuki
    Yamasaki, Akihiro
    BUILDING AND ENVIRONMENT, 2016, 100 : 197 - 202
  • [5] Characteristics of formaldehyde emissions from indoor materials assessed by a method using passive flux sampler measurements
    Plaisance, H.
    Blondel, A.
    Desauziers, V.
    Mocho, P.
    BUILDING AND ENVIRONMENT, 2014, 73 : 249 - 255
  • [6] Emission characteristics of diethylhexyl phthalate (DEHP) from building materials determined using a passive flux sampler and micro-chamber
    Shinohara, Naohide
    Mizukoshi, Atsushi
    Uchiyama, Mayumi
    Tanaka, Hirofumi
    PLOS ONE, 2019, 14 (09):
  • [7] CHAMBER TESTING OF ORGANIC EMISSION FROM BUILDING AND FURNISHING MATERIALS
    COLOMBO, A
    DEBORTOLI, M
    PECCHIO, E
    SCHAUENBURG, H
    SCHLITT, H
    VISSERS, H
    SCIENCE OF THE TOTAL ENVIRONMENT, 1990, 91 : 237 - 249
  • [8] Formaldehyde emission behavior of building materials: On-site measurements and modeling approach to predict indoor air pollution
    Bourdin, Delphine
    Mocho, Pierre
    Desauziers, Valerie
    Plaisance, Herve
    JOURNAL OF HAZARDOUS MATERIALS, 2014, 280 : 164 - 173
  • [9] Formaldehyde emission monitoring from a variety of solid wood, plywood, blockboard and flooring products manufactured for building and furnishing materials
    Boehm, Martin
    Salem, Mohamed Z. M.
    Srba, Jaromir
    JOURNAL OF HAZARDOUS MATERIALS, 2012, 221 : 68 - 79
  • [10] The home-made in situ passive flux sampler for the measurement of monoterpene emission flux: preliminary studies
    Mariusz Marć
    Jacek Namieśnik
    Bożena Zabiegała
    Analytical and Bioanalytical Chemistry, 2015, 407 : 6879 - 6884