Effect of the Mobile Phase Compositions on the Confirmation Analysis of Some Prohibited Substances in Sport by LC–ESI–MS/MS

被引:0
|
作者
Ebru Uçaktürk
Arif Ahmet Başaran
Ali Haydar Demirel
机构
[1] Hacettepe University,Faculty of Pharmacy, Department of Analytical Chemistry
[2] Hacettepe University,Faculty of Pharmacy, Department of Pharmacognosy
[3] Hacettepe University,Faculty of Sport Science, Exercise and Sport Physiology
[4] Hacettepe University,Turkish Doping Control Center
来源
Chromatographia | 2020年 / 83卷
关键词
Peptides; Mobile phase additives; Doping; Triple quadrupole tandem mass spectrometry; Solid-phase extraction; Urine;
D O I
暂无
中图分类号
学科分类号
摘要
In this study, the influence of the different mobile phase compositions on the sensitivity and chromatographic performance of prohibited small peptides (< 2 kDa), their metabolites, and non-peptide substances (anamorelin, ibutamoren) were demonstrated using LC–electrospray ionization coupled with triple quadrupole tandem mass spectrometry (LC–ESI–MS/MS). In the mobile phase, widely used mobile phase additives, ammonium formate (AF), formic acid (FA), and dimethylsulfoxide (DMSO) were employed with different organic phase modifiers such as acetonitrile (ACN) and methanol (MeOH). To evaluate the limit of detection (LOD) and matrix effect of analytes, urine samples were prepared by solid-phase extraction (SPE), and then, their analysis was performed by LC–ESI–MS/MS. LOD values of analytes were found to be between 0.05–2 ng mL−1 except for ibutamoren, anamorelin, and leuprolide (5–9), which had LOD values of lower than 0.05 ng mL−1. The best results related to sensitivity and chromatographic performance for the analysis of the analytes were achieved using ACN-based mobile phase containing 0.1% FA, which led to less ion suppression for most analytes compared to other employed mobile phase compositions. The proposed method to use for confirmation analysis of analytes was validated with respect to selectivity, carryover, precision, the limit of identification (LOI), recovery, matrix effect, and robustness. The applicability of the method in real urine samples was demonstrated by analyzing two different excretion urine samples containing leuprolide and triptorelin.
引用
收藏
页码:1397 / 1411
页数:14
相关论文
共 50 条
  • [41] LC-MS/MS analysis of polyfluoroalkyl substances in environmental water samples
    Organtini, Kari
    Rosnack, Kenneth
    Cleland, Gareth
    Stevens, Douglas
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2019, 257
  • [42] Proteomic analysis of the tetraspanin web using LC-ESI-MS/MS and MALDI-FTICR-MS
    André, M
    Le Caer, JP
    Greco, C
    Planchon, S
    El Nemer, W
    Boucheix, C
    Rubinstein, E
    Chamot-Rooke, J
    Le Naour, F
    [J]. PROTEOMICS, 2006, 6 (05) : 1437 - 1449
  • [43] Methods for the analysis of organophosphorus flame retardants—Comparison of GC-EI-MS, GC-NCI-MS, LC-ESI-MS/MS, and LC-APCI-MS/MS
    Tokumura, Masahiro
    Miyake, Yuichi
    Wang, Qi
    Nakayama, Hayato
    Amagai, Takashi
    Ogo, Sayaka
    Kume, Kazunari
    Kobayashi, Takeshi
    Takasu, Shinji
    Ogawa, Kumiko
    [J]. Journal of Environmental Science and Health - Part A Toxic/Hazardous Substances and Environmental Engineering, 2018, 53 (05): : 475 - 481
  • [44] Comparing chromatography columns for the separation and ESI LC-MS/MS analysis of peptide mixtures
    Schweiger-Hufnagel, U.
    Toll, H.
    Huber, C.
    [J]. MOLECULAR & CELLULAR PROTEOMICS, 2005, 4 (08) : S344 - S344
  • [45] Separation and identification of lipid classes by normal phase LC-ESI/MS/MS on a cyanopropyl column
    Olsson, Petter
    Holmback, Jan
    Nilsson, Ulrika
    Herslof, Bengt
    [J]. EUROPEAN JOURNAL OF LIPID SCIENCE AND TECHNOLOGY, 2014, 116 (05) : 653 - 658
  • [46] Analysis and Confirmation of Rodenticide Pindone in Human Plasma by IC–ESI–IT–MS
    Xiao-Hong Chen
    Mei-Qiang Cai
    Mi-Cong Jin
    [J]. Chromatographia, 2009, 70 : 1201 - 1206
  • [47] Development of a novel SPE-LC-ESI-MS/MS method for analysis of organoarsenicals in water
    Mangalgiri, Kiranmayi
    Lee, Jessica
    Blaney, Lee
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2014, 247
  • [48] Quantitative determination of lysophosphatidic acid by LC/ESI/MS/MS employing a reversed phase HPLC column
    Shan, Lian
    Jaffe, Keeve
    Li, Shanping
    Davis, Lorelei
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 864 (1-2): : 22 - 28
  • [49] A quantitative analysis of the polyamine in lung cancer patient fingernails by LC-ESI-MS/MS
    Min, Jun Zhe
    Matsumoto, Akihito
    Li, Gao
    Jiang, Ying-Zi
    Yu, Hai-fu
    Todoroki, Kenichiro
    Inoue, Koichi
    Toyo'oka, Toshimasa
    [J]. BIOMEDICAL CHROMATOGRAPHY, 2014, 28 (04) : 492 - 499
  • [50] Simultaneous analysis and occurrences of six pharmaceuticals in surface water by LC/ESI-MS/MS
    Kim, ByungJu
    Myung, Seung-Woon
    [J]. ANALYTICAL SCIENCE AND TECHNOLOGY, 2010, 23 (06): : 572 - 578