Effect of the Mobile Phase Compositions on the Confirmation Analysis of Some Prohibited Substances in Sport by LC–ESI–MS/MS

被引:0
|
作者
Ebru Uçaktürk
Arif Ahmet Başaran
Ali Haydar Demirel
机构
[1] Hacettepe University,Faculty of Pharmacy, Department of Analytical Chemistry
[2] Hacettepe University,Faculty of Pharmacy, Department of Pharmacognosy
[3] Hacettepe University,Faculty of Sport Science, Exercise and Sport Physiology
[4] Hacettepe University,Turkish Doping Control Center
来源
Chromatographia | 2020年 / 83卷
关键词
Peptides; Mobile phase additives; Doping; Triple quadrupole tandem mass spectrometry; Solid-phase extraction; Urine;
D O I
暂无
中图分类号
学科分类号
摘要
In this study, the influence of the different mobile phase compositions on the sensitivity and chromatographic performance of prohibited small peptides (< 2 kDa), their metabolites, and non-peptide substances (anamorelin, ibutamoren) were demonstrated using LC–electrospray ionization coupled with triple quadrupole tandem mass spectrometry (LC–ESI–MS/MS). In the mobile phase, widely used mobile phase additives, ammonium formate (AF), formic acid (FA), and dimethylsulfoxide (DMSO) were employed with different organic phase modifiers such as acetonitrile (ACN) and methanol (MeOH). To evaluate the limit of detection (LOD) and matrix effect of analytes, urine samples were prepared by solid-phase extraction (SPE), and then, their analysis was performed by LC–ESI–MS/MS. LOD values of analytes were found to be between 0.05–2 ng mL−1 except for ibutamoren, anamorelin, and leuprolide (5–9), which had LOD values of lower than 0.05 ng mL−1. The best results related to sensitivity and chromatographic performance for the analysis of the analytes were achieved using ACN-based mobile phase containing 0.1% FA, which led to less ion suppression for most analytes compared to other employed mobile phase compositions. The proposed method to use for confirmation analysis of analytes was validated with respect to selectivity, carryover, precision, the limit of identification (LOI), recovery, matrix effect, and robustness. The applicability of the method in real urine samples was demonstrated by analyzing two different excretion urine samples containing leuprolide and triptorelin.
引用
收藏
页码:1397 / 1411
页数:14
相关论文
共 50 条
  • [31] Rapid Analysis of 27 Components of Isodon serra by LC-ESI-MS-MS
    Liu, Pengwei
    Du, Yingfeng
    Zhang, Xiaowei
    Sheng, Xiaona
    Shi, Xiaowei
    Zhao, Chengcheng
    Zhu, Hong
    Wang, Na
    Wang, Qiao
    Zhang, Lantong
    [J]. CHROMATOGRAPHIA, 2010, 72 (3-4) : 265 - 273
  • [32] LC-ESI/MS/MS method for rapid screening and confirmation of 44 exogenous anabolic steroids in human urine
    Jeon, Byoung Wook
    Yoo, Hye Hyun
    Jeong, Eun Sook
    Kim, Ho Jun
    Jin, Changbae
    Kim, Dong Hyun
    Lee, Jaeick
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 401 (04) : 1353 - 1363
  • [33] LC-ESI/MS/MS method for rapid screening and confirmation of 44 exogenous anabolic steroids in human urine
    Byoung Wook Jeon
    Hye Hyun Yoo
    Eun Sook Jeong
    Ho Jun Kim
    Changbae Jin
    Dong Hyun Kim
    Jaeick Lee
    [J]. Analytical and Bioanalytical Chemistry, 2011, 401 : 1353 - 1363
  • [34] Analysis of perchlorate in water by reversed-phase LC/ESI.MS/MS using an internal standard technique
    Li, YT
    George, EJ
    [J]. ANALYTICAL CHEMISTRY, 2005, 77 (14) : 4453 - 4458
  • [35] Comprehensive target analysis for 19 pyrethroids in tea and orange samples based on LC-ESI-QqQ-MS/MS and LC-ESI-Q-ToF/MS
    Wan, Jing
    He, Peng
    Chen, Yuanshan
    Zhu, Qiujin
    [J]. LWT-FOOD SCIENCE AND TECHNOLOGY, 2021, 151
  • [36] Methods for the analysis of organophosphorus flame retardantsComparison of GC-EI-MS, GC-NCI-MS, LC-ESI-MS/MS, and LC-APCI-MS/MS
    Tokumura, Masahiro
    Miyake, Yuichi
    Wang, Qi
    Nakayama, Hayato
    Amagai, Takashi
    Ogo, Sayaka
    Kume, Kazunari
    Kobayashi, Takeshi
    Takasu, Shinji
    Ogawa, Kumiko
    [J]. JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-TOXIC/HAZARDOUS SUBSTANCES & ENVIRONMENTAL ENGINEERING, 2018, 53 (05): : 475 - 481
  • [37] LC-ESI-MS/MS identification and characterization of ponatinib in vivo phase I and phase II metabolites
    Attwa, Mohamed W.
    Kadi, Adnan A.
    Darwish, Hany W.
    Amer, Sawsan M.
    AlRabiah, Haitham
    [J]. CLINICA CHIMICA ACTA, 2018, 485 : 144 - 151
  • [38] LC-MS/MS analysis of polyfluoroalkyl substances in environmental water samples
    Organtini, Kari
    Rosnack, Kenneth
    Cleland, Gareth
    Stevens, Douglas
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2019, 257
  • [39] Proteomic analysis of the tetraspanin web using LC-ESI-MS/MS and MALDI-FTICR-MS
    André, M
    Le Caer, JP
    Greco, C
    Planchon, S
    El Nemer, W
    Boucheix, C
    Rubinstein, E
    Chamot-Rooke, J
    Le Naour, F
    [J]. PROTEOMICS, 2006, 6 (05) : 1437 - 1449
  • [40] Comparing chromatography columns for the separation and ESI LC-MS/MS analysis of peptide mixtures
    Schweiger-Hufnagel, U.
    Toll, H.
    Huber, C.
    [J]. MOLECULAR & CELLULAR PROTEOMICS, 2005, 4 (08) : S344 - S344