Effect of the Mobile Phase Compositions on the Confirmation Analysis of Some Prohibited Substances in Sport by LC–ESI–MS/MS

被引:0
|
作者
Ebru Uçaktürk
Arif Ahmet Başaran
Ali Haydar Demirel
机构
[1] Hacettepe University,Faculty of Pharmacy, Department of Analytical Chemistry
[2] Hacettepe University,Faculty of Pharmacy, Department of Pharmacognosy
[3] Hacettepe University,Faculty of Sport Science, Exercise and Sport Physiology
[4] Hacettepe University,Turkish Doping Control Center
来源
Chromatographia | 2020年 / 83卷
关键词
Peptides; Mobile phase additives; Doping; Triple quadrupole tandem mass spectrometry; Solid-phase extraction; Urine;
D O I
暂无
中图分类号
学科分类号
摘要
In this study, the influence of the different mobile phase compositions on the sensitivity and chromatographic performance of prohibited small peptides (< 2 kDa), their metabolites, and non-peptide substances (anamorelin, ibutamoren) were demonstrated using LC–electrospray ionization coupled with triple quadrupole tandem mass spectrometry (LC–ESI–MS/MS). In the mobile phase, widely used mobile phase additives, ammonium formate (AF), formic acid (FA), and dimethylsulfoxide (DMSO) were employed with different organic phase modifiers such as acetonitrile (ACN) and methanol (MeOH). To evaluate the limit of detection (LOD) and matrix effect of analytes, urine samples were prepared by solid-phase extraction (SPE), and then, their analysis was performed by LC–ESI–MS/MS. LOD values of analytes were found to be between 0.05–2 ng mL−1 except for ibutamoren, anamorelin, and leuprolide (5–9), which had LOD values of lower than 0.05 ng mL−1. The best results related to sensitivity and chromatographic performance for the analysis of the analytes were achieved using ACN-based mobile phase containing 0.1% FA, which led to less ion suppression for most analytes compared to other employed mobile phase compositions. The proposed method to use for confirmation analysis of analytes was validated with respect to selectivity, carryover, precision, the limit of identification (LOI), recovery, matrix effect, and robustness. The applicability of the method in real urine samples was demonstrated by analyzing two different excretion urine samples containing leuprolide and triptorelin.
引用
收藏
页码:1397 / 1411
页数:14
相关论文
共 50 条
  • [21] Sensitivity of GC-EI/MS, GC-EI/MS/MS, LC-ESI/MS/MS, LC-Ag+CIS/MS/MS, and GC-ESI/MS/MS for analysis of anabolic steroids in doping control
    Cha, Eunju
    Kim, Sohee
    Kim, Ho Jun
    Lee, Kang Mi
    Kim, Ki Hun
    Kwon, Oh-Seung
    Lee, Jaeick
    [J]. DRUG TESTING AND ANALYSIS, 2015, 7 (11-12) : 1040 - 1049
  • [22] Adduct Formation in ESI/MS by Mobile Phase Additives
    Kruve, Anneli
    Kaupmees, Karl
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2017, 28 (05) : 887 - 894
  • [23] Capillary-LC-μESI-MS/MS and nano-LC-nano ESI-MS/MS analysis using a single binary pump capillary LC system:: Applications in proteomics
    Song, L
    Choi, KS
    Park, YM
    Kazim, AL
    Marlar, K
    Kong, ES
    Park, EM
    Kim, YH
    Koo, KH
    Chae, HZ
    [J]. JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2005, 28 (09) : 1271 - 1289
  • [24] Enhanced Sensitivity for the Analysis of Perfluoroethercarboxylic Acids Using LC-ESI-MS/MS: Effects of Probe Position, Mobile Phase Additive, and Capillary Voltage
    Brase, Richard A.
    Spink, David C.
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2020, 31 (10) : 2124 - 2132
  • [25] Investigation of the biotransformation of melarsoprol by electrochemistry coupled to complementary LC/ESI–MS and LC/ICP–MS analysis
    Anne Baumann
    Thorben Pfeifer
    Daniel Melles
    Uwe Karst
    [J]. Analytical and Bioanalytical Chemistry, 2013, 405 : 5249 - 5258
  • [26] Complementary analysis of human CSF proteins by nano LC MALDI and ESI/MS/MS
    Viner, R.
    Zhang, T.
    Miller, K.
    [J]. MOLECULAR & CELLULAR PROTEOMICS, 2005, 4 (08) : S311 - S311
  • [27] Rapid Analysis of 27 Components of Isodon serra by LC–ESI-MS–MS
    Pengwei Liu
    Yingfeng Du
    Xiaowei Zhang
    Xiaona Sheng
    Xiaowei Shi
    Chengcheng Zhao
    Hong Zhu
    Na Wang
    Qiao Wang
    Lantong Zhang
    [J]. Chromatographia, 2010, 72 : 265 - 273
  • [28] Analysis of selenomethylselenocysteine and selenomethionine by LC-ESI-MS/MS with diethyl ethoxymethylenemalonate derivatization
    Rebane, Riin
    Herodes, Koit
    Leito, Ivo
    [J]. ANALYST, 2011, 136 (24) : 5241 - 5246
  • [29] Confirmation and determination of carboxylic acids in root exudates using LC-ESI-MS
    Chen, Zuliang
    Jin, Xiaoyin
    Wang, Qinqping
    Lin, Yuman
    Gan, Li
    Tang, Caixing
    [J]. JOURNAL OF SEPARATION SCIENCE, 2007, 30 (15) : 2440 - 2446
  • [30] LC-ESI-MS-MS method for the analysis of tetrabromobisphenol A in sediment and sewage sludge
    Saint-Louis, R
    Pelletier, E
    [J]. ANALYST, 2004, 129 (08) : 724 - 730