Optical readout uncooled infrared imaging detector using knife-edge filter operation

被引:11
|
作者
Zhang Q. [1 ]
Miao Z. [1 ]
Guo Z. [1 ]
Dong F. [1 ]
Xiong Z. [1 ]
Wu X. [1 ]
Chen D. [2 ]
Li C. [2 ]
Jiao B. [2 ]
机构
[1] Key Laboratory of Mechanical Behavior and Design of Materials, University of Science and Technology of China
[2] Institute of Microelectronics, Chinese Academy of Science
基金
中国国家自然科学基金;
关键词
TP206+.1;
D O I
10.1007/s11801-007-7014-2
中图分类号
学科分类号
摘要
An optical readout uncooled infrared (IR) imaging detector of bimaterial cantilever array using knife-edge filter operation (KEFO) is demonstrated. The angle change of each cantilever in a focal plane array (FPA) can be simultaneously detected with a resolution of 10-5 degree. A deformation magnifying substrate-free micro-cantilever unit with multi-fold interval metallized legs is specially designed and modeled. A FPA with 160 × 160 pixels is fabricated and thermal images with noise equivalent temperature difference (NETD) of 400 mK are obtained by this imaging detector. © 2007 Tianjin University of Technology.
引用
收藏
页码:119 / 122
页数:3
相关论文
共 50 条
  • [2] Analysis of Optical Readout Sensitivity for Uncooled Infrared Detector
    Cheng Teng
    Zhang Qing-Chuan
    Jiao Bin-Bin
    Chen Da-Peng
    Wu Xiao-Ping
    CHINESE PHYSICS LETTERS, 2009, 26 (12)
  • [3] Analysis of optical readout sensitivity for uncooled infrared imaging based on optical readout
    Cheng, Teng
    Zhang, Qingchuan
    Gao, Jie
    Mao, Liang
    Wu, Xiaoping
    Chen, Dapeng
    Guangxue Xuebao/Acta Optica Sinica, 2012, 32 (02):
  • [4] An optical readout method based uncooled infrared imaging system
    Jiao, Binbin
    Li, Chaobo
    Chen, Dapeng
    Ye, Tianchun
    Ou, Yi
    Dong, Lijun
    Zhang, Qingchuan
    Guo, Zheying
    Dong, Fengliang
    INTERNATIONAL JOURNAL OF INFRARED AND MILLIMETER WAVES, 2008, 29 (03): : 261 - 271
  • [5] An Optical Readout Method Based Uncooled Infrared Imaging System
    Binbin Jiao
    Chaobo Li
    Dapeng Chen
    Tianchun Ye
    Yi Ou
    Lijun Dong
    Qingchuan Zhang
    Zheying Guo
    Fengliang Dong
    International Journal of Infrared and Millimeter Waves, 2008, 29 : 261 - 271
  • [6] Performance analysis of microcantilever arrays for optical readout uncooled infrared imaging
    Guo, Zheying
    Zhang, Qingchuan
    Dong, Fengliang
    Chen, Dapeng
    Xiong, Zhiming
    Miao, Zhengyu
    Li, Chaobo
    Jiao, Binbin
    Wu, Xiaoping
    SENSORS AND ACTUATORS A-PHYSICAL, 2007, 137 (01) : 13 - 19
  • [7] 2-DIMENSIONAL OPERATION OF A SCANNING OPTICAL MICROSCOPE BY VIBRATING KNIFE-EDGE TOMOGRAPHY
    SAMSON, S
    KORPEL, A
    APPLIED OPTICS, 1995, 34 (02): : 285 - 289
  • [8] Optical knife-edge technique for nanomechanical displacement detection
    Karabacak, D.
    Kouh, T.
    Huang, C. C.
    Ekinci, K. L.
    APPLIED PHYSICS LETTERS, 2006, 88 (19)
  • [9] Optical readout sensitivity of deformed microreflector for uncooled infrared detector: theoretical model and experimental validation
    Cheng, Teng
    Zhang, Qingchuan
    Jiao, Binbin
    Chen, Dapeng
    Wu, Xiaoping
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2009, 26 (11) : 2353 - 2361
  • [10] In situ tomography of femtosecond optical beams with a holographic knife-edge
    Strohaber, J.
    Kaya, G.
    Kaya, N.
    Hart, N.
    Kolomenskii, A. A.
    Paulus, G. G.
    Schuessler, H. A.
    OPTICS EXPRESS, 2011, 19 (15): : 14321 - 14334