Optical readout uncooled infrared imaging detector using knife-edge filter operation

被引:11
|
作者
Zhang Q. [1 ]
Miao Z. [1 ]
Guo Z. [1 ]
Dong F. [1 ]
Xiong Z. [1 ]
Wu X. [1 ]
Chen D. [2 ]
Li C. [2 ]
Jiao B. [2 ]
机构
[1] Key Laboratory of Mechanical Behavior and Design of Materials, University of Science and Technology of China
[2] Institute of Microelectronics, Chinese Academy of Science
基金
中国国家自然科学基金;
关键词
TP206+.1;
D O I
10.1007/s11801-007-7014-2
中图分类号
学科分类号
摘要
An optical readout uncooled infrared (IR) imaging detector of bimaterial cantilever array using knife-edge filter operation (KEFO) is demonstrated. The angle change of each cantilever in a focal plane array (FPA) can be simultaneously detected with a resolution of 10-5 degree. A deformation magnifying substrate-free micro-cantilever unit with multi-fold interval metallized legs is specially designed and modeled. A FPA with 160 × 160 pixels is fabricated and thermal images with noise equivalent temperature difference (NETD) of 400 mK are obtained by this imaging detector. © 2007 Tianjin University of Technology.
引用
收藏
页码:119 / 122
页数:3
相关论文
共 50 条
  • [41] VoglerNet: multiple knife-edge diffraction using deep neural network
    Viet-Dung Nguyen
    Huy Phan
    Mansour, Ali
    Coatanhay, Arnaud
    2020 14TH EUROPEAN CONFERENCE ON ANTENNAS AND PROPAGATION (EUCAP 2020), 2020,
  • [42] Accurate measurement of a THz beam radius through a knife-edge technique with a photoconductive antenna detector
    Morikawa, Osamu
    Hattori, Ai
    Yamamoto, Kohji
    Kurihara, Kazuyoshi
    Furuya, Takashi
    Kuwashima, Fumiyoshi
    Kitahara, Hideaki
    Tani, Masahiko
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 2024, 41 (05) : 1254 - 1260
  • [43] Single and double knife-edge pinhole collimators for SPECT imaging of small volumes.
    Pieper, BC
    Metzler, SD
    Bowsher, JE
    Jaszczak, RJ
    JOURNAL OF NUCLEAR MEDICINE, 2002, 43 (05) : 223P - 224P
  • [44] An Optimized Knife-edge Method for On-orbit MTF Estimation of Optical Sensors using Powell Parameter Fitting
    Han, Lu
    Gao, Kun
    Gong, Chen
    Zhu, Zhenyu
    Guo, Yue
    OPTICS AND PHOTONICS FOR INFORMATION PROCESSING XI, 2017, 10395
  • [45] Impact of the light source expanded width on optical readout uncooled infrared system
    Jia, Qian
    Zhao, Yuejin
    Liu, Xiaohua
    Zhu, Weiwen
    Yin, Ganghua
    Dong, Liquan
    2011 INTERNATIONAL CONFERENCE ON OPTICAL INSTRUMENTS AND TECHNOLOGY: OPTICAL SYSTEMS AND MODERN OPTOELECTRONIC INSTRUMENTS, 2011, 8197
  • [46] Geometry-based, Gaussian profile model for optical knife-edge displacement sensor
    Zameroski, Ross
    Gomez, Michael
    Schmitz, Tony
    PRECISION ENGINEERING-JOURNAL OF THE INTERNATIONAL SOCIETIES FOR PRECISION ENGINEERING AND NANOTECHNOLOGY, 2022, 73 : 470 - 476
  • [47] Micro knife-edge optical measurement devices fabricated by SOI and CMOS MEMS processes
    Chang, Tzu-Lin
    Tseng, Victor Farm-Guoo
    Chiu, Yi
    2007 IEEE/LEOS INTERNATIONAL CONFERENCE ON OPTICAL MEMS AND NANOPHOTONICS, 2007, : 31 - 32
  • [48] Optical knife-edge displacement sensor for high-speed atomic force microscopy
    Braunsmann, Christoph
    Prucker, Veronika
    Schaeffer, Tilman E.
    APPLIED PHYSICS LETTERS, 2014, 104 (10)
  • [49] Prompt gamma imaging of passively shaped proton fields with a knife-edge slit camera
    Priegnitz, M.
    Barczyk, S.
    Keitz, I.
    Mein, S.
    Stappen, F. V.
    Janssens, G.
    Hotoiu, L.
    Smeets, J.
    Fiedler, F.
    Prieels, D.
    Enghardt-, W.
    Pausch, G.
    Richter, C.
    RADIOTHERAPY AND ONCOLOGY, 2016, 118 : S86 - S87
  • [50] Determination of beam width and quality for pulsed lasers using the knife-edge method
    Bachmann, L
    Zezell, DM
    Maldonado, EP
    INSTRUMENTATION SCIENCE & TECHNOLOGY, 2003, 31 (01) : 47 - 52