Dose Verification for Tumor Motion with Different Treatment Planning Systems: A Dynamic Thorax Phantom Study

被引:0
|
作者
Shih-Neng Yang
Chun-Wei Lin
Mu-Bai Chang
Geoffrey G. Zhang
Kuei-Ting Chou
Yu-Rou Chiou
Shung-Shung Sun
Louis Lui
Tsung-Jung Ho
Tzung-Chi Huang
机构
[1] China Medical University,Department of Biomedical Imaging and Radiological Science
[2] China Medical University Hospital,Department of Radiation Oncology
[3] Cathay General Hospital,Department of Radiation Oncology
[4] Tainan Municipal An-Nan Hospital,Department of Radiation Oncology
[5] Moffitt Cancer Center,Department of Radiation Oncology
[6] China Medical University Hospital,Department of Nuclear Medicine and PET Center
[7] China Medical University,College of Chinese Medicine
[8] Asia University,Department of Bioinformatics and Medical Engineering
关键词
Four-dimensional computed tomography; Maximum-intensity projection; Respiratory motion; Dose verification;
D O I
暂无
中图分类号
学科分类号
摘要
During radiation therapy for lung cancer, the respiratory motion of the target increases error and affects the treatment outcome. A four-dimensional computed tomography (4D-CT) technology developed recently can be used to obtain snapshot thoracic CT images during the entire respiratory cycle, which can be helpful in visualization of the tumor displacement in respiratory motion. This study employed a dynamic phantom to simulate tumor respiratory motion, with motion amplitudes of 2, 5 and 10 mm in the superior-inferior direction and motion periods of 4 and 6 s. 4D-CT imaging was applied to record the movement of the target, and maximum-intensity projection (MIP) imaging was used to define the internal target volume (ITV). Treatment plans were generated using three different treatment techniques—tomotherapy, intensity-modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT). In addition, using interchangeable insert modules (an ionization chamber for point dose measurement and Gafchromic EBT3 film for planar dose distribution) in the dynamic phantom, the dose received by the target was measured. The dose received with motion was compared with that received under stationary conditions for dose errors due to respiratory motion. The point dose differences between moving and stationary conditions for tomotherapy, IMRT and VMAT were 0.48 ± 0.51%, 0.17 ± 0.45%, and 0.68 ± 0.70%, respectively; and at motion amplitudes of 2, 5, and 10 mm, the mean dose differences were 0.27 ± 0.38%, 0.37 ± 0.55% and 0.68 ± 0.74%, respectively. Based on planar dose analysis, at motion amplitudes of 2 and 5 mm, the dose distribution differences between moving and stationary conditions using the three treatment methods were all very small, and all passed the gamma index test with a criterion of 3%/3 mm, while at an amplitude of 10 mm, the edge of the ITV was associated with significantly greater dose errors. As studies have shown that in only approximately 10% of pulmonary tumors move with an amplitude >10 mm, 4D-CT MIP imaging in combination with delineation of the ITV may resolve the issue of dose error in most cases. For tumors with large motion amplitudes due to respiration, respiratory gating method may be used to reduce healthy lung tissues inside treatment field.
引用
收藏
页码:46 / 54
页数:8
相关论文
共 50 条
  • [21] Evaluation of Dose Difference in the Delivered Dose due to Lung Tumor Motion in Conventional, Conformal and IMRT Treatment Techniques using In-house Developed Dynamic Phantom
    Boopathy, Raghavendiran
    Nagarajan, Vivekanandan
    Rajasekaran, Dhanabalan
    Padmanaban, Sriram
    Sukumaran, Prabakar
    Sankarrao, Balakrishnan Irde
    Venkataraman, Lakshmanan Alathur
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2010, 30 (01) : 41 - 45
  • [22] A dynamic thorax phantom for the assessment of cardiac and respiratory motion correction in PET/MRI: A preliminary evaluation
    Fieseler, Michael
    Kugel, Harald
    Gigengack, Fabian
    Koesters, Thomas
    Buether, Florian
    Quick, Harald H.
    Faber, Cornelius
    Jiang, Xiaoyi
    Schaefers, Klaus P.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 702 : 59 - 63
  • [23] Use of Small 3D Radiochromic Dosimeters and a Motion Phantom for Dose Verification of Dynamic MLC Tracking Radiotherapy
    Costa, F.
    Menten, M.
    Doran, S.
    Adamovics, J.
    Hanson, I.
    Nill, S.
    Oelfke, U.
    MEDICAL PHYSICS, 2018, 45 (06) : E142 - E142
  • [24] Dose delivery accuracy on helical tomotherapy for 4-dimensional tumor motion - a phantom study
    Holla, Raghavendra
    Khanna, David
    Narayanan, V. K. Sathiya
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2021, 26 (03) : 380 - 388
  • [25] Verification of treatment planning using the new water phantom at the HFR Petten
    Morrissey, J
    Moss, R
    Pantry, C
    Sauerwein, W
    Wittig, A
    Bourhis-Martin, E
    Stecher-Rasmussen, F
    Voorbraak, W
    RESEARCH AND DEVELOPMENT IN NEUTRON CAPTURE THERAPY, 2002, : 495 - 498
  • [26] Dosimetric influence of tumor motion for different types of lung stereotactic treatment planning
    Perez, V. Gonzalez
    Contreras, V. Crispin
    Mocholi, D. Abad
    Salido, A. Bartres
    Alemany, V. De Los Dolores
    De la Flor, C. Guardino
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S192 - S193
  • [27] Comparison of Dose Distributions Calculated Using Different Planning Systems with Radiochromic Film Measurements in An Inhomogeneous Phantom
    Lovelock, D.
    Lim, S.
    Yorke, E.
    Kirov, A.
    LoSasso, T.
    MEDICAL PHYSICS, 2012, 39 (06) : 3828 - 3828
  • [28] Dose verification of dynamic MLC-tracked radiotherapy using small PRESAGE® 3D dosimeters and a motion phantom
    Costa, Filipa
    Menten, Martin J.
    Doran, Simon
    Adamovics, John
    Hanson, Ian M.
    Nill, Simeon
    Oelfke, Uwe
    10TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE), 2019, 1305
  • [29] Evaluating the effects of variation in CT scanning parameters on the image quality and Hounsfield units for optimization of dose in radiotherapy treatment planning: A semi-anthropomorphic thorax phantom study
    Sorooshfard, Elahe
    Tahmasbi, Marziyeh
    Chegeni, Nahid
    Birgani, Mohammad Javad Tahmasebi
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2023, 19 (02) : 426 - 434
  • [30] A comprehensive study on the heterogeneity dose calculation accuracy in IMRT using an anthropomorphic thorax phantom
    Davidson, S.
    Popple, R.
    Ibbott, G.
    Followill, D.
    MEDICAL PHYSICS, 2007, 34 (06) : 2520 - 2520