A comprehensive study on the heterogeneity dose calculation accuracy in IMRT using an anthropomorphic thorax phantom

被引:0
|
作者
Davidson, S.
Popple, R.
Ibbott, G.
Followill, D.
机构
[1] Univ Texas, MD Anderson Canc Ctr, Houston, TX 77030 USA
[2] Univ Alabama, Birmingham, AL USA
关键词
D O I
10.1118/1.2761232
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To provide a comprehensive study on the accuracy of many commonly used Intensity Modulated Radiation Therapy (IMRT) treatment planning systems using the Radiological Physics Center's (RPC) anthropomorphic thorax phantom. Method and Materials: Treatment planning systems (TPSs) from Corvus, Eclipse, Pinnacle, and Tomotherapy were evaluated using the RPC anthropomorphic phantom. Treatment plans were designed using the same clinical constraints and prescriptions so that 96% of the planning target volume (PTV) was covered by the prescription dose. The phantom is equipped with TLD located in the tumor, heart, and spinal cord and radiochromic film located in three anatomical planes intersecting the tumor center and extending into the lung. IMRT QA was performed to adjust the calculated dose distributions in order to isolate the effects of heterogeneity. Comparisons were made between each TPS calculation and measurement. In two instances, re‐calculations of the original correction based pencil beam (PB) plans were performed using the superposition convolution (SC) method. Results: TPSs employing superposition convolution algorithms predicted dose within 3.6% of the target TLD, while TPSs using correction based pencil beam algorithms predicted dose within 5.0% of the target TLD. Both algorithm types showed variations (2% to 38% in the cord and heart) in predicting low dose to normal structures. The dose distributions within the PTV and penumbra lung regions showed good agreement when using an SC algorithm. However, TPSs using the PB type algorithm overestimated dose in the PTV and underestimated the extent of penumbra broadening corresponding to the surrounding lung. Conclusion: This work demonstrated that superposition convolution algorithms found in widely used IMRT treatment planning systems are able to calculate the dose accurately to the PTV and penumbra regions when low density heterogeneities are involved. Conflict of Interest: This work supported by PHS CA010953 and CA081647 awarded by NCI, DHHS. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2520 / 2520
页数:1
相关论文
共 50 条
  • [1] Hctergeneity dose calculation accuracy in IMRT using an anthropomorphic thorax phantom
    Davidson, S.
    Prado, K.
    Ibbott, G.
    Followill, D.
    [J]. MEDICAL PHYSICS, 2006, 33 (06) : 2106 - 2106
  • [2] Accuracy of two heterogeneity dose calculation algorithms for IMRT in treatment plans designed using an anthropomorphic thorax phantom
    Davidson, Scott E.
    Ibbott, Geoffrey S.
    Prado, Karl L.
    Dong, Lei
    Liao, Zhongxing
    Followill, David S.
    [J]. MEDICAL PHYSICS, 2007, 34 (05) : 1850 - 1857
  • [3] Technical note: Heterogeneity dose calculation accuracy in IMRT: Study of five commercial treatment planning systems using an anthropomorphic thorax phantom
    Davidson, Scott E.
    Popple, Richard A.
    Ibbott, Geoffrey S.
    Followill, David S.
    [J]. MEDICAL PHYSICS, 2008, 35 (12) : 5434 - 5439
  • [4] The evaluation of several commercial IMRT treatment planning systems heterogeneity dose calculation algorithms using an anthropomorphic thorax phantom
    Davidson, S
    Followill, D
    Ibbott, G
    Prado, K
    [J]. MEDICAL PHYSICS, 2005, 32 (06) : 1988 - 1988
  • [5] Technical note: Heterogeneity dose calculation accuracy in IMRT: Study of five commercial treatment planning systems using an anthropomorphic thorax phantom" (vol 35, pg 5434, 2008)
    Davidson, Scott E.
    Popple, Richard A.
    Ibbott, Geoffrey S.
    Followill, David S.
    [J]. MEDICAL PHYSICS, 2009, 36 (06) : 2345 - 2345
  • [6] Assessment of CyberKnife's heterogeneity dose calculation algorithm and respiratory tracking system using an anthropomorphic thorax phantom
    Nitsch, P.
    Ibbott, G.
    Dieterich, S.
    Followill, D.
    [J]. MEDICAL PHYSICS, 2007, 34 (06) : 2641 - 2642
  • [7] Accuracy of dose calculation algorithms for static and rotational IMRT in the thorax
    Sini, C.
    Broggi, S.
    Fiorino, C.
    Cattaneo, G. M.
    Calandrino, R.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S184 - S184
  • [8] END-TO-END IMRT EVALUATION USING SEMI-ANTHROPOMORPHIC THORAX PHANTOM
    Udrea, Andreea A.
    Dumitrache, Mihai T.
    Dumitrache, Alina
    Vlasceanu, Maria
    Popescu, Aurel I.
    [J]. ROMANIAN REPORTS IN PHYSICS, 2022, 74 (01)
  • [9] Accuracy of dose calculation algorithms for static and rotational IMRT of lung cancer: A phantom study
    Sini, Carla
    Broggi, Sara
    Fiorino, Claudio
    Cattaneo, Giovanni Mauro
    Calandrino, Riccardo
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2015, 31 (04): : 382 - 390
  • [10] Dosimetric Accuracy Analysis of Dose Calculation Algorithms Using Inhomogeneity Phantom for IMRT Treatment Plan
    Lah, J.
    Park, J.
    Suh, T.
    Shin, D.
    Lee, S.
    Yoon, M.
    Park, S.
    [J]. MEDICAL PHYSICS, 2009, 36 (06)