Dose verification of dynamic MLC-tracked radiotherapy using small PRESAGE® 3D dosimeters and a motion phantom

被引:1
|
作者
Costa, Filipa [1 ,2 ]
Menten, Martin J. [1 ,2 ]
Doran, Simon [3 ]
Adamovics, John [4 ]
Hanson, Ian M. [1 ,2 ]
Nill, Simeon [1 ,2 ]
Oelfke, Uwe [1 ,2 ]
机构
[1] Inst Canc Res, Joint Dept Phys, London SM2 5NG, England
[2] Royal Marsden NHS Fdn Trust, London SM2 5NG, England
[3] Inst Canc Res, CRUK & EPSRC Canc Imaging Ctr, London SM2 5NG, England
[4] Rider Univ, Dept Chem & Biol, Lawrenceville, NJ 08648 USA
基金
英国工程与自然科学研究理事会;
关键词
D O I
10.1088/1742-6596/1305/1/012068
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
With the increasing complexity of radiotherapy treatments typical 1D and 2D quality assurance (QA) detectors may fail to detect out-of-plane dose discrepancies, in particular in the presence of motion. In this work, small samples of the PRESAGE (R) 3D radiochromic dosimeter were used in combination with a motion phantom to measure real-time multileaf collimator (MLC)-tracked radiotherapy treatments. A different sample of PRESAGE (R) was irradiated for each of three different irradiation scenarios: (1) static: static sample, without tracking (2) motion: moving sample, without tracking and (3) tracking: moving sample, with tracking. Our in-house software DynaTrack dynamically moves the linac's MLC leafs based on the target position. The doses delivered to the samples were reconstructed based on the recorded positions of the MLC and phantom during the beam delivery. PRESAGE (R) samples were imaged with an in-house optical-CT scanner. Comparison between simulated and measured 3D dose showed good agreement for all three irradiation scenarios (static: 99.2%; motion: 99.7%; tracking: 99.3% with a 3%, 2 mm and a 10% threshold local gamma criterion), failing only at the edges of the PRESAGE (R) samples (similar to 6 mm). Given that the dose distributions deposited using the DynaTrack system have been independently verified, this experiment demonstrates the ability of PRESAGE to measure 3D doses correctly in a tracking context. We conclude that this methodology could be used in the future to validate the delivery of dynamic MLC-tracked radiotherapy.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Use of Small 3D Radiochromic Dosimeters and a Motion Phantom for Dose Verification of Dynamic MLC Tracking Radiotherapy
    Costa, F.
    Menten, M.
    Doran, S.
    Adamovics, J.
    Hanson, I.
    Nill, S.
    Oelfke, U.
    MEDICAL PHYSICS, 2018, 45 (06) : E142 - E142
  • [2] Do Presage 3D Dosimeters Show Dose Fractionation Sensitivity?
    Klawikowski, S.
    Adamovics, J.
    Alqathami, M.
    Benning, R.
    Ibbott, G.
    MEDICAL PHYSICS, 2014, 41 (06) : 344 - 344
  • [3] Study of PRESAGE® dosimeter for end-to-end 3D radiotherapy verification using an anthropomorphic phantom with bespoke dosimeter insert
    Mohyedin, Muhammad Zamir
    Zin, Hafiz Mohd
    Abubakar, Auwal
    Rahman, Ahmad Taufek Abdul
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2024, 47 (03) : 955 - 966
  • [4] Motion-induced proton dose change measured by 3D deformable dosimeters in an anthropomorphic phantom
    Jensen, S.
    Ehrbar, S.
    Worm, E.
    Muren, L.
    Tanadini-Lang, S.
    Petersen, J.
    Balling, P.
    Poulsen, P.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S387 - S389
  • [5] 3D dosimetric validation of motion compensation concepts in radiotherapy using an anthropomorphic dynamic lung phantom
    Mann, P.
    Witte, M.
    Moser, T.
    Lang, C.
    Runz, A.
    Johnen, W.
    Berger, M.
    Biederer, J.
    Karger, C. P.
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (02): : 573 - 595
  • [6] Development of 3D Printed Phantom for Dose Verification in Radiotherapy for the Patient with Metal Artefacts Inside
    Adliene, Diana
    Jaselske, Evelina
    Urbonavicius, Benas Gabrielis
    Laurikaitiene, Jurgita
    Rudzianskas, Viktoras
    Didvalis, Tadas
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2018, VOL 3, 2019, 68 (03): : 643 - 647
  • [7] Motion-induced dose perturbations in photon radiotherapy and proton therapy measured by deformable liver-shaped 3D dosimeters in an anthropomorphic phantom
    Vindbaek, Simon
    Ehrbar, Stefanie
    Worm, Esben
    Muren, Ludvig
    Tanadini-Lang, Stephanie
    Petersen, Jorgen
    Balling, Peter
    Poulsen, Per
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2024, 31
  • [8] Assessment of the Suitability of 3D PRESAGE Phantom for Relative Dose Measurements in a FLASH Electron Beam
    Elliston, C.
    Rahman, M.
    Wang, Y.
    Sloop, A.
    Sunnerberg, J.
    Zhang, R.
    Adamovics, J.
    Wuu, C.
    MEDICAL PHYSICS, 2022, 49 (06) : E192 - E193
  • [9] Preclinical dose verification using a 3D printed mouse phantom for radiobiology experiments
    Esplen, Nolan
    Therriault-Proulx, Francois
    Beaulieu, Luc
    Bazalova-Carter, Magdalena
    MEDICAL PHYSICS, 2019, 46 (11) : 5294 - 5303
  • [10] 3D dose verification of breathing adapted radiotherapy using gel dosimetry
    Maansson, S.
    Gustavsson, H.
    Karlsson, A.
    Wittgren, L.
    Back, S.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S151 - S151