A Fluorescence Immunochromatographic Assay Using Europium (III) Chelate Microparticles for Rapid, Quantitative and Sensitive Detection of Creatine Kinase MB

被引:0
|
作者
Xiao-Hong Lai
Rong-Liang Liang
Tian-Cai Liu
Zhi-Ning Dong
Ying-Song Wu
Lin-Hai Li
机构
[1] Guangzhou General Hospital of Guangzhou Military Command of PLA,Department of Laboratory Medicine
[2] Guangzhou University of Chinese Medicine,State Key Laboratory of Organ Failure, Guangdong Provincial Key Laboratory of Tropical Disease Research, School of Biotechnology
[3] Southern Medical University,undefined
来源
Journal of Fluorescence | 2016年 / 26卷
关键词
Acute myocardial infarction; Creatine kinase MB; Eu (III) chelate microparticles; Fluorescence immunochromatographic assay;
D O I
暂无
中图分类号
学科分类号
摘要
The isoenzyme creatine kinase MB is very important for diagnosis of acute myocardial infarction (AMI). Some CK-MB immunoassays are sensitive, accurate and available for clinical application, but they are expensive and time-consuming procedures. Furthermore, conventional fluorescence immunochromatographic assays (FL-ICAs) have suffered from background fluorescence interference and low analytical sensitivity. A rapid and simple FL-ICA with Eu (III) chelate polystyrene microparticles was developed to determine CK-MB in 50uL serum samples using a portable test strip reader by measuring the fluorescence peak heights of the test line (HT) and the control line (HC) in 12 min. The assay was reliable with a good correlation coefficient between HT/HC ratio and CK-MB concentration in samples. A linear range was 0.85–100.29 ng/mL for CK-MB, and the LOD was 0.029 ng/mL. The intra- and inter-assay coefficients of variation (CV) were both <10 % and the average recoveries were from 90.17 % -112.63 % for CK-MB. The system performed well in interference experiments. Furthermore, a highly significant correlation (r = 0.9794, P < 0.001) between this method and the commercially available bioMérieux mini VIDAS system were attained for measuring 120 CK-MB samples. These results indicated that the Eu (III) chelate microparticles-based FL-ICA is simple, fast, highly sensitive, reliable, and reproducible for point-of-care testing of CK-MB concentrations in serum.
引用
收藏
页码:987 / 996
页数:9
相关论文
共 47 条
  • [31] Europium (III) chelate microparticle-based lateral flow immunoassay strips for rapid and quantitative detection of antibody to hepatitis B core antigen
    Liang, Rong-Liang
    Deng, Qiao-Ting
    Chen, Zhen-Hua
    Xu, Xu-Ping
    Zhou, Jian-Wei
    Liang, Jun-Yu
    Dong, Zhi-Ning
    Liu, Tian-Cai
    Wu, Ying-Song
    SCIENTIFIC REPORTS, 2017, 7
  • [32] Lateral flow immunoassay strips based on europium(III) chelate microparticle for the rapid and sensitive detection of Trichinella spiralis infection in whole blood samples of pigs
    Wang, Xinyu
    Li, Aizhe
    Wang, Ruizhe
    Hou, Tianji
    Chen, Huixin
    Wang, Jing
    Liu, Mingyuan
    Li, Chen
    Ding, Jing
    FRONTIERS IN CELLULAR AND INFECTION MICROBIOLOGY, 2022, 12
  • [33] Sensitive Quantitative Protein Concentration Method Using Luminescent Resonance Energy Transfer on a Layer-by-Layer Europium(III) Chelate Particle Sensor
    Harma, Harri
    Dahne, Lars
    Pihlasalo, Sari
    Suojanen, Janne
    Peltonen, Jouko
    Hanninen, Pekka
    ANALYTICAL CHEMISTRY, 2008, 80 (24) : 9781 - 9786
  • [34] A sensitive immunochromatographic assay using colloidal gold-antibody probe for rapid detection of fumonisin B1 in corn
    Wang, Xi-Chun
    Fan, Hai-Xin
    Fan, Meng-Xue
    Li, Fu-Hui
    Feng, Shi-Bin
    Li, Jin-Chun
    Wu, Jin-Jie
    Li, Yu
    Wang, Jia-Sheng
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2016, 33 (09): : 1435 - 1443
  • [35] Development of quantitative immunochromatographic assay for rapid and sensitive detection of carbohydrate antigen 19-9 (CA 19-9) in human plasma
    Baryeh, Kwaku
    Takalkar, Sunitha
    Lund, Michelle
    Liu, Guodong
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2017, 146 : 285 - 291
  • [36] Sample Preincubation Strategy for Sensitive and Quantitative Detection of Clenbuterol in Swine Urine Using a Fluorescent Microsphere-Based Immunochromatographic Assay
    Deng, Sheng L.
    Shan, Shan
    Xu, Chao L.
    Liu, Dao F.
    Xiong, Yong H.
    Wei, Hua
    Lai, Wei H.
    JOURNAL OF FOOD PROTECTION, 2014, 77 (11) : 1998 - 2003
  • [37] Rapid and sensitive detection of melanin using glutathione conjugated gold nanocluster based fluorescence quenching assay
    Siddiqui, Mohd Farhan
    Jeon, Sojeong
    Kim, Moon-Moo
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2021, 247
  • [38] Combining Ultralong Organic Phosphorescent Nanoparticle-Based Lateral Flow Strip Assay With Deep Learning: A Quantitative Detection Method for Creatine Kinase MB
    Wu, Yi
    Zhang, Yiming
    Yi, Weijing
    Fu, Yusheng
    Ren, Chunhui
    Guo, Jinhong
    Guo, Jiuchuan
    IEEE Sensors Journal, 2024, 24 (24) : 41787 - 41796
  • [39] Development of a rapid and sensitive europium (III) chelate microparticle-based lateral flow test strip for the detection and epidemiological surveillance of porcine epidemic diarrhea virus
    Jianbo Liu
    Hongyan Shi
    Guangyi Cong
    Jianfei Chen
    Xin Zhang
    Da Shi
    Liyan Cao
    Xiaobo Wang
    Jialin Zhang
    Zhaoyang Ji
    Zhaoyang Jing
    Li Feng
    Archives of Virology, 2020, 165 : 1049 - 1056
  • [40] Development of a rapid and sensitive europium (III) chelate microparticle-based lateral flow test strip for the detection and epidemiological surveillance of porcine epidemic diarrhea virus
    Liu, Jianbo
    Shi, Hongyan
    Cong, Guangyi
    Chen, Jianfei
    Zhang, Xin
    Shi, Da
    Cao, Liyan
    Wang, Xiaobo
    Zhang, Jialin
    Ji, Zhaoyang
    Jing, Zhaoyang
    Feng, Li
    ARCHIVES OF VIROLOGY, 2020, 165 (05) : 1049 - 1056