A Fluorescence Immunochromatographic Assay Using Europium (III) Chelate Microparticles for Rapid, Quantitative and Sensitive Detection of Creatine Kinase MB

被引:0
|
作者
Xiao-Hong Lai
Rong-Liang Liang
Tian-Cai Liu
Zhi-Ning Dong
Ying-Song Wu
Lin-Hai Li
机构
[1] Guangzhou General Hospital of Guangzhou Military Command of PLA,Department of Laboratory Medicine
[2] Guangzhou University of Chinese Medicine,State Key Laboratory of Organ Failure, Guangdong Provincial Key Laboratory of Tropical Disease Research, School of Biotechnology
[3] Southern Medical University,undefined
来源
Journal of Fluorescence | 2016年 / 26卷
关键词
Acute myocardial infarction; Creatine kinase MB; Eu (III) chelate microparticles; Fluorescence immunochromatographic assay;
D O I
暂无
中图分类号
学科分类号
摘要
The isoenzyme creatine kinase MB is very important for diagnosis of acute myocardial infarction (AMI). Some CK-MB immunoassays are sensitive, accurate and available for clinical application, but they are expensive and time-consuming procedures. Furthermore, conventional fluorescence immunochromatographic assays (FL-ICAs) have suffered from background fluorescence interference and low analytical sensitivity. A rapid and simple FL-ICA with Eu (III) chelate polystyrene microparticles was developed to determine CK-MB in 50uL serum samples using a portable test strip reader by measuring the fluorescence peak heights of the test line (HT) and the control line (HC) in 12 min. The assay was reliable with a good correlation coefficient between HT/HC ratio and CK-MB concentration in samples. A linear range was 0.85–100.29 ng/mL for CK-MB, and the LOD was 0.029 ng/mL. The intra- and inter-assay coefficients of variation (CV) were both <10 % and the average recoveries were from 90.17 % -112.63 % for CK-MB. The system performed well in interference experiments. Furthermore, a highly significant correlation (r = 0.9794, P < 0.001) between this method and the commercially available bioMérieux mini VIDAS system were attained for measuring 120 CK-MB samples. These results indicated that the Eu (III) chelate microparticles-based FL-ICA is simple, fast, highly sensitive, reliable, and reproducible for point-of-care testing of CK-MB concentrations in serum.
引用
下载
收藏
页码:987 / 996
页数:9
相关论文
共 47 条
  • [21] A sensitive immunochromatographic assay using colloidal gold-antibody probe for the rapid detection of semicarbazide in meat specimens
    Tang, Yong
    Xu, Jinting
    Wang, Wuzhou
    Xiang, Junjian
    Yang, Hongyu
    EUROPEAN FOOD RESEARCH AND TECHNOLOGY, 2011, 232 (01) : 9 - 16
  • [22] A rapid and sensitive quantitative kinase activity assay using a convenient 96-well format
    Asthagiri, AR
    Horwitz, AF
    Lauffenburger, DA
    ANALYTICAL BIOCHEMISTRY, 1999, 269 (02) : 342 - 347
  • [23] Drug-tolerant detection of anti-drug antibodies in an antigen-binding assay using europium chelate fluorescence
    van Strien, Jolinde
    Dijk, Lisanne
    Atiqi, Sadaf
    Schouten, Rogier
    Bloem, Karien
    Wolbink, Gerrit Jan
    Loeff, Floris
    Rispens, Theo
    JOURNAL OF IMMUNOLOGICAL METHODS, 2023, 514
  • [24] Time-Resolved Fluorescence Immunochromatographic Assay Developed Using Two Idiotypic Nanobodies for Rapid, Quantitative, and Simultaneous Detection of Aflatoxin and Zearalenone in Maize and Its Products
    Tang, Xiaoqian
    Li, Peiwu
    Zhang, Qi
    Zhang, Zhaowei
    Zhang, Wen
    Jiang, Jun
    ANALYTICAL CHEMISTRY, 2017, 89 (21) : 11520 - 11528
  • [25] Detection of heart-type fatty acid binding protein in serum by a rapid quantitative time-resolved fluorescence immunochromatographic assay
    Xu, Buzhuo
    Xi, Yun
    Liang, Jiamin
    Lin, Junyue
    Whittaker, Kelly
    Tang, Hao
    Luo, Shuhong
    Weng, Yiming
    Huang, Ruopan
    Song, Xuedong
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2022, 15 (09): : 293 - 302
  • [26] A sensitive immunochromatographic assay using colloidal gold-antibody probe for rapid detection of pharmaceutical indomethacin in water samples
    Li, Dawei
    Wei, Shuang
    Yang, Hong
    Li, Yuan
    Deng, Anping
    BIOSENSORS & BIOELECTRONICS, 2009, 24 (07): : 2277 - 2280
  • [27] Development of a gold nanoparticle-based lateral flow immunochromatographic assay for the rapid and quantitative detection of thymidine kinase 1 in human serum
    Ye, Liya
    Xu, Xinxin
    Qu, Aihua
    Kuang, Hua
    Liu, Liqiang
    Xu, Chuanlai
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2024, 245
  • [28] Rapid and sensitive detection of Metapneumovirus in clinical specimens by indirect fluorescence assay using a monoclonal antibody
    Manoha, C.
    Bour, J. B.
    Pitoiset, C.
    Darniot, M.
    Aho, S.
    Pothier, P.
    JOURNAL OF MEDICAL VIROLOGY, 2008, 80 (01) : 154 - 158
  • [29] Europium (III) chelate microparticle-based lateral flow immunoassay strips for rapid and quantitative detection of antibody to hepatitis B core antigen
    Rong-Liang Liang
    Qiao-Ting Deng
    Zhen-Hua Chen
    Xu-Ping Xu
    Jian-Wei Zhou
    Jun-Yu Liang
    Zhi-Ning Dong
    Tian-Cai Liu
    Ying-Song Wu
    Scientific Reports, 7
  • [30] Immunosensor-based rapid quantitative detection of Newcastle disease virus antibodies using innovative gold immunochromatographic assay
    Yang, F.
    Li, Y.
    Jin, X.
    Xu, Q.
    Cheng, F.
    Wang, X.
    JOURNAL OF APPLIED MICROBIOLOGY, 2020, 129 (06) : 1751 - 1757