A Fluorescence Immunochromatographic Assay Using Europium (III) Chelate Microparticles for Rapid, Quantitative and Sensitive Detection of Creatine Kinase MB

被引:0
|
作者
Xiao-Hong Lai
Rong-Liang Liang
Tian-Cai Liu
Zhi-Ning Dong
Ying-Song Wu
Lin-Hai Li
机构
[1] Guangzhou General Hospital of Guangzhou Military Command of PLA,Department of Laboratory Medicine
[2] Guangzhou University of Chinese Medicine,State Key Laboratory of Organ Failure, Guangdong Provincial Key Laboratory of Tropical Disease Research, School of Biotechnology
[3] Southern Medical University,undefined
来源
Journal of Fluorescence | 2016年 / 26卷
关键词
Acute myocardial infarction; Creatine kinase MB; Eu (III) chelate microparticles; Fluorescence immunochromatographic assay;
D O I
暂无
中图分类号
学科分类号
摘要
The isoenzyme creatine kinase MB is very important for diagnosis of acute myocardial infarction (AMI). Some CK-MB immunoassays are sensitive, accurate and available for clinical application, but they are expensive and time-consuming procedures. Furthermore, conventional fluorescence immunochromatographic assays (FL-ICAs) have suffered from background fluorescence interference and low analytical sensitivity. A rapid and simple FL-ICA with Eu (III) chelate polystyrene microparticles was developed to determine CK-MB in 50uL serum samples using a portable test strip reader by measuring the fluorescence peak heights of the test line (HT) and the control line (HC) in 12 min. The assay was reliable with a good correlation coefficient between HT/HC ratio and CK-MB concentration in samples. A linear range was 0.85–100.29 ng/mL for CK-MB, and the LOD was 0.029 ng/mL. The intra- and inter-assay coefficients of variation (CV) were both <10 % and the average recoveries were from 90.17 % -112.63 % for CK-MB. The system performed well in interference experiments. Furthermore, a highly significant correlation (r = 0.9794, P < 0.001) between this method and the commercially available bioMérieux mini VIDAS system were attained for measuring 120 CK-MB samples. These results indicated that the Eu (III) chelate microparticles-based FL-ICA is simple, fast, highly sensitive, reliable, and reproducible for point-of-care testing of CK-MB concentrations in serum.
引用
下载
收藏
页码:987 / 996
页数:9
相关论文
共 47 条
  • [1] A Fluorescence Immunochromatographic Assay Using Europium (III) Chelate Microparticles for Rapid, Quantitative and Sensitive Detection of Creatine Kinase MB
    Lai, Xiao-Hong
    Liang, Rong-
    Liu, Tian-Cai
    Dong, Zhi-Ning
    Wu, Ying-Song
    Li, Lin-Hai
    JOURNAL OF FLUORESCENCE, 2016, 26 (03) : 987 - 996
  • [2] SENSITIVE, RAPID ASSAY OF SUBFORMS OF CREATINE-KINASE MB IN PLASMA
    PULEO, PR
    GUADAGNO, PA
    ROBERTS, R
    PERRYMAN, MB
    CLINICAL CHEMISTRY, 1989, 35 (07) : 1452 - 1455
  • [3] Quantitative and rapid detection of microcystin-LR using time-resolved fluorescence immunochromatographic assay based on europium nanospheres
    Zhang, Yi
    Ding, Xin-Liang
    Guo, Ming-Ming
    Han, Ting-Ting
    Huang, Zi-Jian
    Shang, Hong-Tao
    Huang, Biao
    ANALYTICAL METHODS, 2017, 9 (45) : 6430 - 6434
  • [4] A fluorescence immunochromatographic assay for rapid and sensitive detection of human prealbumin in serum
    Yang, Yajie
    Li, Chaohui
    Wang, Wei
    Dong, Tingting
    Xiong, Yonghua
    Shen, Jun
    Lai, Weihua
    ANALYTICAL METHODS, 2015, 7 (20) : 8683 - 8688
  • [5] Rapid immunological detection of copper ions using fluorescence immunochromatographic assay
    Yang, Hao
    Cheng, Long-Qiu
    Kang, Ke-Ren
    Hao, Dai-Ling
    Zhu, Liu-Rong
    Liu, Yang
    Xiang, Jun-Jian
    Huang, Jian-Fang
    FOOD AND AGRICULTURAL IMMUNOLOGY, 2019, 30 (01) : 60 - 73
  • [6] Rapid and sensitive detection of chlordimeform in cucumber and tomato samples using an immunochromatographic assay
    Lu, Qianqian
    Xu, Xinxin
    Guo, Lingling
    Song, Shanshan
    Liu, Liqiang
    Zhu, Yingyue
    Kuang, Hua
    Xu, Chuanlai
    Xu, Liguang
    ANALYST, 2023, 148 (04) : 780 - 786
  • [7] Rapid, quantitative and sensitive immunochromatographic assay based on stripping voltammetric detection of a metal ion label
    Lu, F
    Wang, KH
    Lin, YH
    ANALYST, 2005, 130 (11) : 1513 - 1517
  • [8] Quantitative detection of β2-adrenergic agonists using fluorescence quenching by immunochromatographic assay
    Zhang, Ganggang
    Chen, Minghui
    Liu, Daofeng
    Xiong, Yonghua
    Feng, Ronghua
    Zhong, Pinghai
    Lai, Weihua
    ANALYTICAL METHODS, 2016, 8 (03) : 627 - 631
  • [9] A RAPID, QUANTITATIVE IMMUNOASSAY FOR CREATINE KINASE-MB (CK-MB) USING TANDEM ICON QSR TECHNOLOGY
    KRESS, BC
    FRANK, K
    LEVERETT, L
    NORTON, K
    SWEET, M
    CLINICAL CHEMISTRY, 1989, 35 (06) : 1197 - 1197
  • [10] Rapid and sensitive detection of acrylic acid using a novel fluorescence assay
    Lee, Zhi Yi
    Raghavan, Sarada S.
    Ghadessy, Farid J.
    Teo, Yin Nah
    RSC ADVANCES, 2014, 4 (104) : 60216 - 60220