Dose reduction from loss of backscatter in superficial x-ray radiation therapy with the Pantak SXT 150 unit

被引:0
|
作者
B. J. Healy
S. Sylvander
K. N. Nitschke
机构
[1] Princess Alexandra Hospital,Southern Zone Radiation Oncology Service
[2] Radiation Oncology Queensland,Mater Centre
关键词
superficial x-ray therapy; backscatter; lead shielding;
D O I
暂无
中图分类号
学科分类号
摘要
Loss of backscatter has been measured for a Pantak Therapax SXT 150 superficial x-ray therapy unit. Ionisation chamber measurements at the surface were performed in solid water with and without underlying lead to confirm the applicability of previous published measurements. Measurements of loss of backscatter with and without lead allowed the effect of underlying lead to be separated from the effect of loss of backscatter. It was found that the difference between the effect of lead and that of air on surface dose is minimal for solid water phantom thickness exceeding 3 cm. Differences up to 3% in dose reduction at the surface were found between this work and previous published results with different x-ray units.
引用
收藏
页码:49 / 55
页数:6
相关论文
共 50 条
  • [31] RADIATION DOSE TO SKIN AND TO GONADS FROM DIAGNOSTIC X-RAY PROCEDURES
    DUGGAN, HE
    OLDE, GL
    CANADIAN MEDICAL ASSOCIATION JOURNAL, 1963, 89 (22) : 1144 - &
  • [32] Generative learning approach for radiation dose reduction in X-ray guided cardiac interventions
    Azizmohammadi, Fariba
    Castellanos, Inaki Navarro
    Miro, Joaquim
    Segars, Paul
    Samei, Ehsan
    Duong, Luc
    MEDICAL PHYSICS, 2022, 49 (06) : 4071 - 4081
  • [33] Transition from dose times area to effective dose of radiation in x-ray examination
    Voronin K.V.
    Biomedical Engineering, 1998, 32 (3) : 134 - 136
  • [34] Radiation Risk from Airport X-ray Backscatter Scanners: Should We Fear the Microsievert?
    Zanotti-Fregonara, Paolo
    Hindie, Elif
    RADIOLOGY, 2011, 261 (01) : 330 - 331
  • [35] A high-resolution dose calculation engine for X-ray microbeams radiation therapy
    Keshmiri, Sarvenaz
    Brocard, Sylvan
    Serduc, Raphael
    Adam, Jean-Francois
    MEDICAL PHYSICS, 2022, 49 (06) : 3999 - 4017
  • [36] X-Ray Imaging Dose to Patients in the Era of Image-Guided Radiation Therapy
    Ding, G.
    Price, R.
    Coffey, C.
    MEDICAL PHYSICS, 2008, 35 (06) : 2966 - +
  • [37] Nanoparticle Location and Material-Dependent Dose Enhancement in X-ray Radiation Therapy
    Hossain, Mainul
    Su, Ming
    JOURNAL OF PHYSICAL CHEMISTRY C, 2012, 116 (43): : 23047 - 23052
  • [38] Low-dose X-ray fluoroscopy for image guided radiation therapy (IGRT)
    Zhang, X.
    Wang, J.
    Zhu, L.
    Xing, L.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S642 - S642
  • [39] Patient radiation dose reduction using an X-ray imaging noise reduction technology for cardiac angiography and intervention
    Nakamura, Shigeru
    Kobayashi, Tomoko
    Funatsu, Atsushi
    Okada, Tadahisa
    Mauti, Maria
    Waizumi, Yuki
    Yamada, Shinichi
    HEART AND VESSELS, 2016, 31 (05) : 655 - 663
  • [40] Patient radiation dose reduction using an X-ray imaging noise reduction technology for cardiac angiography and intervention
    Shigeru Nakamura
    Tomoko Kobayashi
    Atsushi Funatsu
    Tadahisa Okada
    Maria Mauti
    Yuki Waizumi
    Shinichi Yamada
    Heart and Vessels, 2016, 31 : 655 - 663