Dose reduction from loss of backscatter in superficial x-ray radiation therapy with the Pantak SXT 150 unit

被引:0
|
作者
B. J. Healy
S. Sylvander
K. N. Nitschke
机构
[1] Princess Alexandra Hospital,Southern Zone Radiation Oncology Service
[2] Radiation Oncology Queensland,Mater Centre
关键词
superficial x-ray therapy; backscatter; lead shielding;
D O I
暂无
中图分类号
学科分类号
摘要
Loss of backscatter has been measured for a Pantak Therapax SXT 150 superficial x-ray therapy unit. Ionisation chamber measurements at the surface were performed in solid water with and without underlying lead to confirm the applicability of previous published measurements. Measurements of loss of backscatter with and without lead allowed the effect of underlying lead to be separated from the effect of loss of backscatter. It was found that the difference between the effect of lead and that of air on surface dose is minimal for solid water phantom thickness exceeding 3 cm. Differences up to 3% in dose reduction at the surface were found between this work and previous published results with different x-ray units.
引用
收藏
页码:49 / 55
页数:6
相关论文
共 50 条
  • [11] Yohkoh/SXT soft X-ray observations of sudden mass loss from the solar corona
    Hudson, HS
    Acton, LW
    Alexander, D
    Freeland, SL
    Lemen, JR
    Harvey, KL
    SOLAR WIND EIGHT - PROCEEDINGS OF THE EIGHTH INTERNATIONAL SOLAR WIND CONFERENCE, 1996, (382): : 88 - 91
  • [12] Paediatric x-ray radiation dose reduction and image quality analysis
    Martin, L.
    Ruddlesden, R.
    Makepeace, C.
    Robinson, L.
    Mistry, T.
    Starritt, H.
    JOURNAL OF RADIOLOGICAL PROTECTION, 2013, 33 (03) : 621 - 633
  • [13] Reduction of scattered radiation dose by X-ray shielding during mammography
    Koo, Bon-Yeoul
    Lee, Kwang-Sung
    RADIATION PHYSICS AND CHEMISTRY, 2020, 177
  • [14] IMPROVEMENT OF THE DOSE DISTRIBUTION OF THE X-RAY THERAPY UNIT RT 305
    ROTH, J
    NEMEC, HW
    BLAUENSTEIN, R
    STRAHLENTHERAPIE, 1982, 158 (06) : 362 - 364
  • [15] The variation of HVL with focal spot to chamber distance as a function of beam quality for the Pantak Therapax 150 X-ray unit and the implications on dose to water determination using the IPEMB code of practice
    John Baines
    Lucy Sim
    Australasian Physical & Engineering Sciences in Medicine, 2014, 37 : 559 - 566
  • [16] The variation of HVL with focal spot to chamber distance as a function of beam quality for the Pantak Therapax 150 X-ray unit and the implications on dose to water determination using the IPEMB code of practice
    Baines, John
    Sim, Lucy
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2014, 37 (03) : 559 - 566
  • [17] RADIATION PROTECTION CONSIDERATIONS FOR ENDO-THERAPY X-RAY UNIT
    PURDY, JA
    WALZ, BJ
    COTTER, G
    PRASAD, SC
    MEDICAL PHYSICS, 1984, 11 (03) : 399 - 399
  • [18] NOISE REDUCTION IN LOW-DOSE X-RAY FLUOROSCOPY FOR IMAGE-GUIDED RADIATION THERAPY
    Jing Wang
    Lei Zhu
    Lei Xing
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 74 (02): : 637 - 643
  • [19] Machine characterization and central axis depth dose data of a superficial x-ray radiotherapy unit
    Xiong, Zhenyu
    Zhong, Yuncheng
    Banks, Thomas I.
    Reynolds, Robert
    Chiu, Tsuicheng
    Tan, Jun
    Zhang, You
    Parsons, David
    Yan, Yulong
    Godley, Andrew
    Stojadinovic, Strahinja
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2023, 9 (01)
  • [20] Surface dose reduction from bone interface in kilovoltage X-ray radiation therapy: a Monte Carlo study of photon spectra
    Chow, James C. L.
    Owrangi, Amir M.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2012, 13 (05): : 215 - 222