Performance assessment of NOVA SDS011 low-cost PM sensor in various microenvironments

被引:0
|
作者
Aca Božilov
Viša Tasić
Nenad Živković
Ivan Lazović
Milan Blagojević
Nikola Mišić
Dušan Topalović
机构
[1] University of Niš,Faculty of Occupational Safety in Niš
[2] Mining and Metallurgy Institute Bor,Institute Vinča
[3] University of Belgrade,undefined
来源
关键词
Air pollution; Monitoring; Particulate matter; Low-cost PM monitor; NOVA SDS011 PM sensor;
D O I
暂无
中图分类号
学科分类号
摘要
Over the last 10 years, as a possible alternative to the conventional approach to air quality monitoring, real-time monitoring systems that use low-cost sensors and sensor platforms have been frequently applied. Generally, the long-term characteristics of low-cost PM sensors and monitoring have not been thoroughly documented except for a few widely used sensors and monitors. This article addresses the laboratory and field validation of three low-cost PM monitors of the same type that use the NOVA SDS011 PM sensor module over a 1-year period. In outdoor environments, we co-located low-cost PM monitors with GRIMM EDM180 monitors at the National Air Quality Monitoring stations. In indoor environments, we co-located them with a Turnkey Osiris PM monitor. Several performance aspects of the PM monitors were examined: operational data coverage, linearity of response, accuracy, precision, and inter-sensor variability. The obtained results show that inter-monitor R values were typically higher than 0.95 regardless of the environment. The tested monitors demonstrate high linearity in comparison with PM10 and PM2.5 concentrations measured in outdoor air with reference-equivalent instrumentation with R2 values ranging from 0.52 up to 0.83. In addition, very good agreement (R2 values ranging from 0.93 up to 0.97) with the gravimetric PM10 and PM2.5 method is obtained in the indoor environment (30 < RH < 70%). High RH (over 70%) negatively affected the PM monitors’ response, especially in the case of PM10 concentrations (high overestimation).
引用
收藏
相关论文
共 50 条
  • [41] Improved Performance of A Low-Cost PDR System through Sensor Calibration and Analysis
    Kim, Yunki
    Lee, Donghyuk
    Kim, Kijung
    Lee, Jangmyung
    2014 IEEE/ASME INTERNATIONAL CONFERENCE ON ADVANCED INTELLIGENT MECHATRONICS (AIM), 2014, : 1747 - 1752
  • [42] Inter- versus Intracity Variations in the Performance and Calibration of Low-Cost PM2.5 Sensors: A Multicity Assessment in India
    Sreekanth, V
    Bhargav, R. Ajay
    Kulkarni, Padmavati
    Puttaswamy, Naveen
    Prabhu, Vignesh
    Agrawal, Pratyush
    Upadhya, Adithi R.
    Rao, Sofiya
    Sutaria, Ronak
    Mor, Suman
    Dey, Sagnik
    Khaiwal, Ravindra
    Balakrishnan, Kalpana
    Tripathi, Sachchida Nand
    Singh, Pratima
    ACS EARTH AND SPACE CHEMISTRY, 2022, 6 (12): : 3007 - 3016
  • [43] Performance of a new, low-cost soil moisture, temperature, and electrical conductivity sensor
    Campbell, Colin S.
    Campbell, Gaylon S.
    Cobos, Douglas R.
    Teare, Brody
    HORTSCIENCE, 2006, 41 (04) : 1024 - 1024
  • [44] Assessing Effects of Salinity on the Performance of a Low-Cost Wireless Soil Water Sensor
    Peddinti, Srinivasa Rao
    Hopmans, Jan W.
    Abou Najm, Majdi
    Kisekka, Isaya
    SENSORS, 2020, 20 (24) : 1 - 14
  • [45] Effect of environmental conditions on the performance of a low-cost atmospheric particulate matter sensor
    Macias-Hernandez, Barbara A.
    Tello-Leal, Edgar
    Barrios, S. Oliver
    Leiva-Guzman, Manuel A.
    Toro, A. Richard
    URBAN CLIMATE, 2023, 52
  • [46] A novel, low-cost, high performance dissolved methane sensor for aqueous environments
    Boulart, Cedric
    Mowlem, Matthew C.
    Connelly, Douglas P.
    Dutasta, Jean-Pierre
    German, Christopher R.
    OPTICS EXPRESS, 2008, 16 (17): : 12607 - 12617
  • [47] Field performance of a low-cost sensor in the monitoring of particulate matter in Santiago, Chile
    Matías Tagle
    Francisca Rojas
    Felipe Reyes
    Yeanice Vásquez
    Fredrik Hallgren
    Jenny Lindén
    Dimitar Kolev
    Ågot K. Watne
    Pedro Oyola
    Environmental Monitoring and Assessment, 2020, 192
  • [48] Field performance of a low-cost sensor in the monitoring of particulate matter in Santiago, Chile
    Tagle, Matias
    Rojas, Francisca
    Reyes, Felipe
    Vasquez, Yeanice
    Hallgren, Fredrik
    Linden, Jenny
    Kolev, Dimitar
    Watne, Agot K.
    Oyola, Pedro
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2020, 192 (03)
  • [49] Performance Analysis and Calibration of a New Low-Cost Capacitance Soil Moisture Sensor
    Kargas, George
    Soulis, Konstantinos X.
    JOURNAL OF IRRIGATION AND DRAINAGE ENGINEERING, 2012, 138 (07) : 632 - 641
  • [50] Performance of a low-cost methane sensor for ambient concentration measurements in preliminary studies
    Eugster, W.
    Kling, G. W.
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2012, 5 (08) : 1925 - 1934