Monte Carlo Simulation of an Electron Irradiation Device for Medical Application of an Electron Linear Accelerator

被引:0
|
作者
Kyoung Won Jang
Manwoo Lee
Heuijin Lim
Sang Koo Kang
Sang Jin Lee
Seung Heon Kim
Dong Eun Lee
Hee Chang Kim
Dong Hyeok Jeong
机构
[1] Dongnam Institute of Radiological & Medical Sciences,Research Center
来源
关键词
Electron beam; Scattering foil; Dosimetry;
D O I
暂无
中图分类号
学科分类号
摘要
A uniform electron field is required for medical applications of electron linear accelerators (LINACs). Electron irradiation devices, including scattering foils and applicators for generating uniform electron fields, are widely used in medical LINACs. In this research, an electron scattering device consisting of scattering foils and applicators was designed for clinical application of a 9-MeV electron LINAC planned at the Dongnam Institute of Radiological & Medical Sciences. Monte Carlo simulations were performed to calculate the depth dose and the beam profile curves in a water phantom by using the EGSnrc Monte Carlo code.
引用
收藏
页码:588 / 591
页数:3
相关论文
共 50 条
  • [1] Monte Carlo Simulation of an Electron Irradiation Device for Medical Application of an Electron Linear Accelerator
    Jang, Kyoung Won
    Lee, Manwoo
    Lim, Heuijin
    Kang, Sang Koo
    Lee, Sang Jin
    Kim, Seung Heon
    Lee, Dong Eun
    Kim, Hee Chang
    Jeong, Dong Hyeok
    [J]. JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2020, 76 (07) : 588 - 591
  • [2] Application of variance reduction techniques in Monte Carlo simulation of clinical electron linear accelerator
    Zoubair, M.
    El Bardouni, T.
    El Gonnouni, L.
    Boulaich, Y.
    El Bakkari, B.
    El Younoussi, C.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2012, 661 (01): : 93 - 97
  • [3] Modeling 6 MeV Electron Beam From Medical Linear Accelerator Using Monte Carlo Simulation
    Dechsupa, P.
    Tannanonta, C.
    Phaisangittisakul, N.
    [J]. MEDICAL PHYSICS, 2009, 36 (06)
  • [4] Monte Carlo calculations of electron beam output factors for a medical linear accelerator
    Kapur, A
    Ma, CM
    Mok, EC
    Findley, DO
    Boyer, AL
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (12): : 3479 - 3494
  • [5] Benchmarking of electron beam parameters based on Monte Carlo linear accelerator simulation
    Zhang, Fan
    Zhou, Mi
    Liu, Jing
    Yue, Lu
    Deng, Lihua
    Xu, Zhijian
    Wang, Gang
    [J]. TRANSLATIONAL CANCER RESEARCH, 2020, 9 (02) : 577 - 584
  • [6] Monte Carlo simulation for Neptun 10 PC medical linear accelerator and calculations of output factor for electron beam
    Toossi, Mohammad Taghi Bahreyni
    Momennezhad, Mehdi
    Hashemi, Seyed Mohammad
    [J]. REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2012, 17 (02) : 115 - 118
  • [7] Monte Carlo simulation of a medical linear accelerator for radiotherapy use
    Serrano, B.
    Hachem, A.
    Franchisseur, E.
    Herault, J.
    Marcie, S.
    Costa, A.
    Bensadoun, R. J.
    Barthe, J.
    Gerard, J. P.
    [J]. RADIATION PROTECTION DOSIMETRY, 2006, 119 (1-4) : 506 - 509
  • [8] Monte Carlo Characterization of a Medical Linear Accelerator for Small Animal Irradiation
    Larraga-Gutierrez, J. M.
    Galvan, E.
    Moreno-Jimenez, S.
    Celis, M. A.
    Diaz-Ruiz, A.
    Rios, C.
    [J]. MEDICAL PHYSICS, 2008, 35 (06)
  • [9] Study and design of an energy monitoring device for an industrial electron accelerator using Monte Carlo simulation
    Yuan, Jushigang
    Zhang, Gefei
    Pang, Shiqiang
    Chen, Taiyan
    Huang, Jiang
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2023, 206
  • [10] Electron mobility and Monte Carlo device simulation of MOSFETs
    Yamakawa, S
    Ueno, H
    Taniguchi, K
    Hamaguchi, C
    Miyatsuji, K
    Masaki, K
    Ravaioli, U
    [J]. VLSI DESIGN, 1998, 6 (1-4) : 27 - 30