Monte Carlo Simulation of an Electron Irradiation Device for Medical Application of an Electron Linear Accelerator

被引:0
|
作者
Kyoung Won Jang
Manwoo Lee
Heuijin Lim
Sang Koo Kang
Sang Jin Lee
Seung Heon Kim
Dong Eun Lee
Hee Chang Kim
Dong Hyeok Jeong
机构
[1] Dongnam Institute of Radiological & Medical Sciences,Research Center
来源
关键词
Electron beam; Scattering foil; Dosimetry;
D O I
暂无
中图分类号
学科分类号
摘要
A uniform electron field is required for medical applications of electron linear accelerators (LINACs). Electron irradiation devices, including scattering foils and applicators for generating uniform electron fields, are widely used in medical LINACs. In this research, an electron scattering device consisting of scattering foils and applicators was designed for clinical application of a 9-MeV electron LINAC planned at the Dongnam Institute of Radiological & Medical Sciences. Monte Carlo simulations were performed to calculate the depth dose and the beam profile curves in a water phantom by using the EGSnrc Monte Carlo code.
引用
收藏
页码:588 / 591
页数:3
相关论文
共 50 条
  • [31] Monte Carlo simulation and dose distribution of low energy electron irradiation of an apple
    Brescia, G
    Moreira, R
    Braby, L
    Castell-Perez, E
    JOURNAL OF FOOD ENGINEERING, 2003, 60 (01) : 31 - 39
  • [32] Monte Carlo simulation of small field electron beams for small animal irradiation
    Lee, Chung-Chi
    Chen, Ai-Mei
    Tung, Chuan-Jong
    Chao, Tsi-Chian
    RADIATION MEASUREMENTS, 2011, 46 (12) : 2003 - 2005
  • [33] Monte Carlo simulation of device structures with one-dimensional electron gas
    Borzdov, Vladimir
    Komarov, Fadei
    Galenchik, Vadim
    Pozdnyakov, Dmitry
    Borzdov, Andrey
    Zhevnyak, Oleg
    MICRO- AND NANOELECTRONICS 2005, 2006, 6260
  • [34] Application of a new Monte Carlo simulation algorithm to electron probe microanalysis
    Llovet, X
    Riveros, A
    Salvat, F
    MIKROCHIMICA ACTA, 1996, : 409 - 417
  • [35] Influence of initial electron beam characteristics on Monte Carlo calculated absorbed dose distributions for linear accelerator electron beams
    Björk, P
    Knöös, T
    Nilsson, P
    PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (22): : 4019 - 4041
  • [36] Application of macro response Monte Carlo method for electron spectrum simulation
    Perles, L. A.
    de Almeida, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (01): : 130 - 133
  • [37] A study on scattered particles from medical linear accelerator head using monte carlo simulation
    Katayose, T. (u5856601@gs.metro-hs.ac.jp), (KEK High Energy Accelerator Research Organization):
  • [38] Monte Carlo benchmark of the experimental evaluation of the activation processes in an electron linear accelerator for radiotherapy applications
    Isolan, Lorenzo
    Sumini, Marco
    Cucchi, Giorgio
    Iori, Mauro
    Sghedoni, Roberto
    RADIATION EFFECTS AND DEFECTS IN SOLIDS, 2016, 171 (9-10): : 808 - 817
  • [39] Monte Carlo Investigation of Photon Beam Characteristics and its Variation with Incident Electron Beam Parameters for Indigenous Medical Linear Accelerator
    Mishra, Subhalaxmi
    Dixit, P. K.
    Selvam, T. Palani
    Yavalkar, Sanket S.
    Deshpande, D. D.
    JOURNAL OF MEDICAL PHYSICS, 2018, 43 (01) : 1 - 8
  • [40] Monte Carlo simulation of large electron fields
    Faddegon, B
    Schreiber, E
    Ding, X
    PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (05): : 741 - 753