Monte Carlo Simulation of an Electron Irradiation Device for Medical Application of an Electron Linear Accelerator

被引:0
|
作者
Kyoung Won Jang
Manwoo Lee
Heuijin Lim
Sang Koo Kang
Sang Jin Lee
Seung Heon Kim
Dong Eun Lee
Hee Chang Kim
Dong Hyeok Jeong
机构
[1] Dongnam Institute of Radiological & Medical Sciences,Research Center
来源
关键词
Electron beam; Scattering foil; Dosimetry;
D O I
暂无
中图分类号
学科分类号
摘要
A uniform electron field is required for medical applications of electron linear accelerators (LINACs). Electron irradiation devices, including scattering foils and applicators for generating uniform electron fields, are widely used in medical LINACs. In this research, an electron scattering device consisting of scattering foils and applicators was designed for clinical application of a 9-MeV electron LINAC planned at the Dongnam Institute of Radiological & Medical Sciences. Monte Carlo simulations were performed to calculate the depth dose and the beam profile curves in a water phantom by using the EGSnrc Monte Carlo code.
引用
收藏
页码:588 / 591
页数:3
相关论文
共 50 条
  • [21] Monte Carlo simulation of electron beams from an accelerator head using PENELOPE
    Sempau, J
    Sánchez-Reyes, A
    Salvat, F
    ben Tahar, HO
    Jiang, SB
    Fernández-Varea, JM
    PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (04): : 1163 - 1186
  • [22] Monte Carlo simulation of single-cell irradiation by an electron microbeam
    J. H. Miller
    M. Sowa Resat
    N. F. Metting
    K. Wei
    D. J. Lynch
    W. E. Wilson
    Radiation and Environmental Biophysics, 2000, 39 : 173 - 177
  • [23] Monte Carlo Simulation of Small Electron Fields for Small Animal Irradiation
    Lee, C.
    Chen, A.
    Chao, T.
    Tung, C.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [24] Full Monte Carlo simulation compared to a simple source model for a dual-energy electron linear accelerator
    Hermida Lopez, M.
    Sempau, J.
    Sauerwein, W.
    Brualla, L.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2016, 192 : 106 - 107
  • [25] Monte Carlo Simulation of Linear Accelerator for Dosimetry Analysis
    Francis, Seenia
    Suresh, Darshana
    Nath, Shalini
    Lakshmi, Saai D. R.
    Jayaraj, P. B.
    Puzhakkal, Niyas
    Pournami, P. N.
    2021 6TH INTERNATIONAL CONFERENCE FOR CONVERGENCE IN TECHNOLOGY (I2CT), 2021,
  • [26] A virtual electron accelerator, based on Monte Carlo, for verification of a commercial Monte Carlo electron treatment planning system
    Wieslander, E
    Traneus, E
    Knööds, T
    RADIOTHERAPY AND ONCOLOGY, 2004, 73 : S375 - S375
  • [27] Electron beam dynamic study and Monte Carlo simulation of accelerator-based irradiation system for natural rubber vulcanization
    Apiwattanakul, P.
    Rimjaem, S.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2020, 466 (466): : 69 - 75
  • [28] Estimation of the focal spot size and shape for a medical linear accelerator by Monte Carlo simulation
    Wang, Lilie L. W.
    Leszczynski, Konrad
    MEDICAL PHYSICS, 2007, 34 (02) : 485 - 488
  • [29] The necessity of a divergent initial electron beam in the Monte-Carlo model of a linear accelerator
    De Smedt, B
    Reynaert, N
    Coghe, M
    Paelinck, L
    Van Duysse, B
    De Wagter, C
    De Neve, W
    Thierens, H
    RADIOTHERAPY AND ONCOLOGY, 2003, 68 : S42 - S42
  • [30] Monte Carlo study of electron dose distributions produced by the elekta precise linear accelerator
    Nedaie, Hassan Ali
    Mosleh-Shirazi, M. A.
    Shariary, M.
    Gharaati, H.
    Allahverdi, M.
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2006, 11 (06) : 287 - 292