Lateral flow immunostrips for the sensitive and rapid determination of 8-hydroxy-2′-deoxyguanosine using upconversion nanoparticles

被引:0
|
作者
Nengying Wu
Yuxi Wei
Lanlan Pan
Xiaolin Yang
Honglan Qi
Qiang Gao
Chengxiao Zhang
机构
[1] Shaanxi Normal University,Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering
来源
Microchimica Acta | 2020年 / 187卷
关键词
Point of care testing; Lateral flow strip; Immunoassay; 8-Hydroxy-2′-deoxyguanosine; Upconversion nanoparticles;
D O I
暂无
中图分类号
学科分类号
摘要
Lateral flow immunostrips were newly designed and a sensitive and rapid fluorometric method for the determination of 8-hydroxy-2′-deoxyguanosine (8-OHdG) as a model target of small biomarker molecules was developed. The upconversion nanoparticles (UCNPs, NaYF4:Yb/Er core, and polyacrylic acid (PAA)-modified shell, size ~ 39 nm, excitation wavelength = 980 nm; emission wavelength = 540 nm) were employed as fluorescence signal material. The 8-OHdG antibody (Ab) was taken as the recognition probe while UCNP-labeled Ab was taken as the signal probe. Bovine serum albumin (BSA) was designed as carrier protein for 8-OHdG to form 8-OHdG-BSA conjugate as the capture probe. The lateral flow immunostrips were prepared by laminating a sample pad (glass fiber membrane), a test pad (nitrocellulose membrane), and adsorption pad (filter paper) on PVP backing. The capture probe was immobilized on the test zone while an IgG antibody taken as the control probe was immobilized on the control zone. When the signal probe and the sample were in sequence loaded on the sample pad, 8-OHdG analyte bound with the signal probe, and then the excess of the signal probe move along the strip and is collected by the capture probe on the test zone while the remnant signal probe is collected by the control probe on the control zone. The signal probe and capture probe were synthesized and characterized. The fluorescence intensity on the test zone was inversely proportional to the concentration of 8-OHdG for the quantitative determination while the fluorescence emission on the control zone was observed to validate the assay. The developed method showed a wide linear range from 0.10 to 10 nM, a quite low detection limit of 0.05 nM, small sample volume requirement (100 μL), short assay time (15 min), and good method reproducibility (RSD = 4.4%, nine immunostrips).
引用
收藏
相关论文
共 50 条
  • [1] Lateral flow immunostrips for the sensitive and rapid determination of 8-hydroxy-2′-deoxyguanosine using upconversion nanoparticles
    Wu, Nengying
    Wei, Yuxi
    Pan, Lanlan
    Yang, Xiaolin
    Qi, Honglan
    Gao, Qiang
    Zhang, Chengxiao
    MICROCHIMICA ACTA, 2020, 187 (07)
  • [2] THE DEVELOPMENT OF A SENSITIVE ANALYSIS FOR 8-HYDROXY-2'-DEOXYGUANOSINE
    FLOYD, RA
    FREE RADICAL RESEARCH COMMUNICATIONS, 1990, 8 (03): : 139 - 141
  • [3] Sensitive and rapid determination of heat shock protein 70 using lateral flow immunostrips and upconversion nanoparticle fluorescence probes
    Wu, Nengying
    Wei, Yuxi
    Pan, Lanlan
    Yang, Xiaolin
    Qi, Honglan
    Gao, Qiang
    Zhang, Chengxiao
    Li, Chen-zhong
    ANALYST, 2022, 147 (15) : 3444 - 3450
  • [4] Detection of 8-hydroxy-2′deoxyadenosine and 8-hydroxy-2′deoxyguanosine by Avidin
    Hooley, Elizabeth
    Conners, Rebecca
    Brady, Leo
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2005, 61 : C220 - C220
  • [5] Highly Sensitive Chitosan and ZrO2 Nanoparticles-Based Electrochemical Sensor for 8-Hydroxy-2′-deoxyguanosine Determination
    Rong, Shengzhong
    Pan, Deng
    Li, Xuehui
    Gao, Mucong
    Yu, Hongwei
    Jiang, Jinghui
    Zhang, Ze
    Zeng, Dongdong
    Pan, Hongzhi
    Chang, Dong
    CURRENT ANALYTICAL CHEMISTRY, 2019, 15 (06) : 648 - 655
  • [6] Colorimetric determination of 8-hydroxy-2'-deoxyguanosine using label-free aptamer and unmodified gold nanoparticles
    Wang, Jia-Cheng
    Wang, Yong-Sheng
    Rang, Wei-Qing
    Xue, Jin-Hua
    Zhou, Bin
    Liu, Lu
    Qian, Qiu-Mei
    Wang, Yong-Song
    Yin, Ji-Cheng
    MICROCHIMICA ACTA, 2014, 181 (9-10) : 903 - 910
  • [7] Tear Levels of 8-hydroxy-2′-deoxyguanosine
    Tong, Louis
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (03) : 1587 - 1587
  • [8] Resonance Rayleigh scattering spectral method for determination of urinary 8-hydroxy-2′-deoxyguanosine using gold nanoparticles as probe
    Guo, Huiqin
    Xue, Kunpeng
    Yan, Liushui
    SENSORS AND ACTUATORS B-CHEMICAL, 2012, 171 : 1038 - 1045
  • [9] IMMUNOAFFINITY ISOLATION OF URINARY 8-HYDROXY-2'-DEOXYGUANOSINE AND 8-HYDROXYGUANINE AND QUANTITATION OF 8-HYDROXY-2'-DEOXYGUANOSINE IN DNA BY POLYCLONAL ANTIBODIES
    DEGAN, P
    SHIGENAGA, MK
    PARK, EM
    ALPERIN, PE
    AMES, BN
    CARCINOGENESIS, 1991, 12 (05) : 865 - 871
  • [10] A highly sensitive automated flow immunosensor based on kinetic exclusion analysis for determination of the cancer marker 8-hydroxy-2′-deoxyguanosine in urine
    Darwish, Ibrahim A.
    Wani, Tanveer A.
    Khalil, Nasr Y.
    Aboul-Fadl, Tarek
    Kadi, Adnan A.
    Al-Majed, Abdul-Rahman A.
    ANALYTICAL METHODS, 2013, 5 (06) : 1502 - 1509