Effective temporal resolution and image quality of volume scanning in 320-row detector CT

被引:0
|
作者
Atsushi Urikura
Takanori Hara
Tsukasa Yoshida
Eiji Nishimaru
Takashi Hoshino
Katsuhiro Ichikawa
Yoshihiro Nakaya
Masahiro Endo
机构
[1] Shizuoka Cancer Center,Division of Diagnostic Radiology
[2] Nakatsugawa Municipal General Hospital,Department of Medical Technology
[3] Shizuoka Cancer Center,Division of Radiation and Proton Therapy Center
[4] Hiroshima University Hospital,Department of Radiology
[5] Osaka College of High Technology,Department of Radiological Technology
[6] Kanazawa University Graduate of Medical Sciences,Division of Health Sciences
关键词
Temporal resolution; Non-helical volume scanning; Computed tomography; Temporal sensitivity profiles; Motion artifact;
D O I
暂无
中图分类号
学科分类号
摘要
To measure the effective temporal resolution (eTR) and image quality for three reconstruction modes for non-helical volume scanning in area detector CT. Temporal sensitivity profiles (TSPs) were obtained and the full width of the TSP at half maximum was used as an index of the eTR. Image quality was assessed by image noise and the corrected artifact index. The half reconstruction mode had a higher eTR than the full and automatic patient motion collection (APMC) reconstructions. Compared to full reconstruction, the image noise with APMC and half reconstruction were increased by 16% and 35%. The corrected artifact index was lowest with APMC. The square root of full width at tenth maximum of the TSP showed a high coefficient of determination (R2 = 0.934) for image noise. This study revealed the TSPs and eTRs for non-helical volume scanning in area detector CT. A high eTR resulted in higher image noise.
引用
收藏
页码:503 / 510
页数:7
相关论文
共 50 条
  • [21] Clinical significance of transluminal attenuation gradient in 320-row area detector coronary CT angiography
    Etsuro Kato
    Shinichiro Fujimoto
    Kazuhisa Takamura
    Yuko Kawaguchi
    Chihiro Aoshima
    Makoto Hiki
    Kanako K. Kumamaru
    Hiroyuki Daida
    Heart and Vessels, 2018, 33 : 462 - 469
  • [22] Evaluation of the CT dose index for scans with an ECG using a 320-row multiple-detector CT scanner
    Kobayashi, Masanao
    Asada, Yasuki
    Matsubara, Kosuke
    Koshida, Kichiro
    Suzuki, Shouichi
    Matsunaga, Yuta
    Kawaguchi, Ai
    Haba, Tomonobu
    Katada, Kazuhiro
    Toyama, Hiroshi
    RADIATION PROTECTION DOSIMETRY, 2015, 167 (04) : 532 - 541
  • [23] Image Quality of Coronary Computed Tomography Angiography with 320-Row Area Detector Computed Tomography in Children with Congenital Heart Disease
    Tada, Akihiro
    Sato, Shuhei
    Kanie, Yuichiro
    Tanaka, Takashi
    Inai, Ryota
    Akagi, Noriaki
    Morimitsu, Yusuke
    Kanazawa, Susumu
    PEDIATRIC CARDIOLOGY, 2016, 37 (03) : 497 - 503
  • [24] Adaptive Iterative Dose Reduction in coronary CT angiography using 320-row CT: Assessment of radiation dose reduction and image quality
    Tomizawa, Nobuo
    Nojo, Takeshi
    Akahane, Masaaki
    Torigoe, Rumiko
    Kiryu, Shigeru
    Ohtomo, Kuni
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2012, 6 (05) : 318 - 324
  • [25] Image quality of coronary computed tomography angiography with 320-Row area detector computed tomography in children with congenital heart disease
    Qin, Jie
    Cai, Songwang
    Peng, Lingrong
    Tang, Wenjie
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 68 (16) : C142 - C142
  • [26] Image Quality of Coronary Computed Tomography Angiography with 320-Row Area Detector Computed Tomography in Children with Congenital Heart Disease
    Akihiro Tada
    Shuhei Sato
    Yuichiro Kanie
    Takashi Tanaka
    Ryota Inai
    Noriaki Akagi
    Yusuke Morimitsu
    Susumu Kanazawa
    Pediatric Cardiology, 2016, 37 : 497 - 503
  • [27] The effect of bolus volume on laryngeal closure and UES opening in swallowing: Kinematic analysis using 320-row area detector CT study
    Shibata, S.
    Inamoto, Y.
    Saitoh, E.
    Kagaya, H.
    Aoyagi, Y.
    Ota, K.
    Akahori, R.
    Fujii, N.
    Palmer, J. B.
    Gonzalez-Fernandez, M.
    JOURNAL OF ORAL REHABILITATION, 2017, 44 (12) : 974 - 981
  • [28] Changes in Pyriform Sinus Morphology in the Head Rotated Position as Assessed by 320-Row Area Detector CT
    Enri Nakayama
    Hitoshi Kagaya
    Eiichi Saitoh
    Yoko Inamoto
    Shuji Hashimoto
    Naoko Fujii
    Kazuhiro Katada
    Daisuke Kanamori
    Haruka Tohara
    Koichiro Ueda
    Dysphagia, 2013, 28 : 199 - 204
  • [29] Changes in Pyriform Sinus Morphology in the Head Rotated Position as Assessed by 320-Row Area Detector CT
    Nakayama, Enri
    Kagaya, Hitoshi
    Saitoh, Eiichi
    Inamoto, Yoko
    Hashimoto, Shuji
    Fujii, Naoko
    Katada, Kazuhiro
    Kanamori, Daisuke
    Tohara, Haruka
    Ueda, Koichiro
    DYSPHAGIA, 2013, 28 (02) : 199 - 204
  • [30] Imaging of the temporal bone in children using low-dose 320-row area detector computed tomography
    Tada, Akihiro
    Sato, Shuhei
    Masaoka, Yoshihisa
    Kanazawa, Susumu
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2017, 61 (04) : 489 - 493