Changes in Pyriform Sinus Morphology in the Head Rotated Position as Assessed by 320-Row Area Detector CT

被引:15
|
作者
Nakayama, Enri [1 ]
Kagaya, Hitoshi [2 ]
Saitoh, Eiichi [2 ]
Inamoto, Yoko [3 ]
Hashimoto, Shuji [4 ]
Fujii, Naoko [5 ]
Katada, Kazuhiro [5 ]
Kanamori, Daisuke [6 ]
Tohara, Haruka [1 ]
Ueda, Koichiro [1 ]
机构
[1] Nihon Univ, Dept Dysphagia Rehabil, Sch Dent, Chiyoda Ku, Tokyo 1018310, Japan
[2] Fujita Hlth Univ, Sch Med, Dept Rehabil 1, Toyoake, Aichi 47011, Japan
[3] Fujita Hlth Univ, Fac Rehabil, Sch Hlth Sci, Toyoake, Aichi, Japan
[4] Fujita Hlth Univ, Sch Med, Dept Hyg, Toyoake, Aichi 47011, Japan
[5] Fujita Hlth Univ, Sch Med, Dept Radiol, Toyoake, Aichi 47011, Japan
[6] Fujita Hlth Univ, Sch Med, Dept Oral & Maxillofacial Surg, Toyoake, Aichi 47011, Japan
关键词
Deglutition; Deglutition disorders; Pyriform sinus; Head rotation; 320-Row area detector CT; ASPIRATION; CLOSURE;
D O I
10.1007/s00455-012-9430-0
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
In patients with unilateral pharyngeal paresis and dysphagia, the head is rotated to the paretic side to prevent food flow to the rotated side during swallowing. Only a few studies to date have reported on pyriform sinus morphology upon head rotation. The purpose of this study was to measure the volume, depth, and cross-sectional area of the pyriform sinus during head rotation using 320-row area detector computed tomography. We imaged the neck during head rotation at 0A degrees and at 30A degrees, 45A degrees, and 60A degrees to the left or right in nine healthy young adults and determined the volume, depth, and cross-sectional area of the pyriform sinus in each position. On the rotated side, volume and cross-sectional area were significantly decreased at 60A degrees. In contrast, volume, cross-sectional area, and depth were all significantly increased on the opposite side at 60A degrees. These results suggest that head rotation at 60A degrees significantly increases the volume, cross-sectional area, and depth of the opposite side, and significantly decreases the volume and depth of the rotated side of the pyriform sinus.
引用
收藏
页码:199 / 204
页数:6
相关论文
共 50 条
  • [1] Changes in Pyriform Sinus Morphology in the Head Rotated Position as Assessed by 320-Row Area Detector CT
    Enri Nakayama
    Hitoshi Kagaya
    Eiichi Saitoh
    Yoko Inamoto
    Shuji Hashimoto
    Naoko Fujii
    Kazuhiro Katada
    Daisuke Kanamori
    Haruka Tohara
    Koichiro Ueda
    Dysphagia, 2013, 28 : 199 - 204
  • [2] Changes in Shape of the Pyriform Sinus in the Rotated-Head Position by Using 320-Detector Row CT
    Nakayama, Enri
    Kagaya, H.
    Saitoh, E.
    Inamoto, Y.
    Fujii, N.
    Baba, M.
    Okada, S.
    Ida, Y.
    Kataoka, Y.
    Kanamori, D.
    Katada, K.
    DYSPHAGIA, 2010, 25 (04) : 380 - 380
  • [3] Volume and Shape of Pyriform Sinus: Measurement by Using 320-Detector Row CT
    Okada, Sumiko
    Nakayama, E.
    Inamoto, Y.
    Saitoh, E.
    Kagaya, H.
    Fujii, N.
    Baba, M.
    Ida, Y.
    Kataoka, Y.
    Kanamori, D.
    Katada, K.
    DYSPHAGIA, 2010, 25 (04) : 381 - 381
  • [4] Acute stroke rapid imaging protocol by 320-row Area Detector CT
    Mori, T.
    Iwata, T.
    Miyazaki, Y.
    Tanno, Y.
    Kasakuar, S.
    Aoyagi, Y.
    Yosioka, K.
    CEREBROVASCULAR DISEASES, 2014, 37 : 206 - 206
  • [5] Clinical significance of transluminal attenuation gradient in 320-row area detector coronary CT angiography
    Kato, Etsuro
    Fujimoto, Shinichiro
    Takamura, Kazuhisa
    Kawaguchi, Yuko
    Aoshima, Chihiro
    Hiki, Makoto
    Kumamaru, Kanako K.
    Daida, Hiroyuki
    HEART AND VESSELS, 2018, 33 (05) : 462 - 469
  • [6] Clinical significance of transluminal attenuation gradient in 320-row area detector coronary CT angiography
    Etsuro Kato
    Shinichiro Fujimoto
    Kazuhisa Takamura
    Yuko Kawaguchi
    Chihiro Aoshima
    Makoto Hiki
    Kanako K. Kumamaru
    Hiroyuki Daida
    Heart and Vessels, 2018, 33 : 462 - 469
  • [7] Specific features of 320-row area detector CT images: comparison with 64-slice multi-detector CT
    Izumi, M.
    Nagata, K.
    Ohmura, T.
    Kodama, M.
    Fujiwara, R.
    Ono, Y.
    Ito, H.
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2009, 11 (0B) : S86 - S86
  • [8] The dynamics of deglutition during head rotation using dynamic 320-row area detector computed tomography
    Kochi, Kazutaka
    Sei, Hirofumi
    Tanabe, Yuki
    Yasuda, Kazunori
    Kido, Teruhito
    Yamada, Hiroyuki
    Taguchi, Aki
    Hato, Naohito
    LARYNGOSCOPE INVESTIGATIVE OTOLARYNGOLOGY, 2023, 8 (03): : 746 - 753
  • [9] Evaluation of Pharyngoesophageal Segment Using 320-Row Area Detector Computed Tomography
    Wattanapan, Pattra
    Kagaya, Hitoshi
    Inamoto, Yoko
    Saitoh, Eiichi
    Shibata, Seiko
    Iida, Takatoshi
    ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 2018, 127 (12): : 888 - 894
  • [10] The Effect of Bolus Viscosity on Laryngeal Closure in Swallowing: Kinematic Analysis Using 320-Row Area Detector CT
    Inamoto, Yoko
    Saitoh, Eiichi
    Okada, Sumiko
    Kagaya, Hitoshi
    Shibata, Seiko
    Ota, Kikuo
    Baba, Mikoto
    Fujii, Naoko
    Katada, Kazuhiro
    Wattanapan, Pattra
    Palmer, Jeffrey B.
    DYSPHAGIA, 2013, 28 (01) : 33 - 42