Changes in Pyriform Sinus Morphology in the Head Rotated Position as Assessed by 320-Row Area Detector CT

被引:15
|
作者
Nakayama, Enri [1 ]
Kagaya, Hitoshi [2 ]
Saitoh, Eiichi [2 ]
Inamoto, Yoko [3 ]
Hashimoto, Shuji [4 ]
Fujii, Naoko [5 ]
Katada, Kazuhiro [5 ]
Kanamori, Daisuke [6 ]
Tohara, Haruka [1 ]
Ueda, Koichiro [1 ]
机构
[1] Nihon Univ, Dept Dysphagia Rehabil, Sch Dent, Chiyoda Ku, Tokyo 1018310, Japan
[2] Fujita Hlth Univ, Sch Med, Dept Rehabil 1, Toyoake, Aichi 47011, Japan
[3] Fujita Hlth Univ, Fac Rehabil, Sch Hlth Sci, Toyoake, Aichi, Japan
[4] Fujita Hlth Univ, Sch Med, Dept Hyg, Toyoake, Aichi 47011, Japan
[5] Fujita Hlth Univ, Sch Med, Dept Radiol, Toyoake, Aichi 47011, Japan
[6] Fujita Hlth Univ, Sch Med, Dept Oral & Maxillofacial Surg, Toyoake, Aichi 47011, Japan
关键词
Deglutition; Deglutition disorders; Pyriform sinus; Head rotation; 320-Row area detector CT; ASPIRATION; CLOSURE;
D O I
10.1007/s00455-012-9430-0
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
In patients with unilateral pharyngeal paresis and dysphagia, the head is rotated to the paretic side to prevent food flow to the rotated side during swallowing. Only a few studies to date have reported on pyriform sinus morphology upon head rotation. The purpose of this study was to measure the volume, depth, and cross-sectional area of the pyriform sinus during head rotation using 320-row area detector computed tomography. We imaged the neck during head rotation at 0A degrees and at 30A degrees, 45A degrees, and 60A degrees to the left or right in nine healthy young adults and determined the volume, depth, and cross-sectional area of the pyriform sinus in each position. On the rotated side, volume and cross-sectional area were significantly decreased at 60A degrees. In contrast, volume, cross-sectional area, and depth were all significantly increased on the opposite side at 60A degrees. These results suggest that head rotation at 60A degrees significantly increases the volume, cross-sectional area, and depth of the opposite side, and significantly decreases the volume and depth of the rotated side of the pyriform sinus.
引用
收藏
页码:199 / 204
页数:6
相关论文
共 50 条
  • [21] Annular Flow in the Upper Esophageal Sphincter Demonstrated with Dynamic 320-row Area Detector Computed Tomography
    Yoko Inamoto
    Eiichi Saitoh
    Jeffrey B. Palmer
    Dysphagia, 2021, 36 : 1088 - 1094
  • [22] Submillisievert imaging protocol using full reconstruction and advanced patient motion correction in 320-row area detector coronary CT angiography
    Yuko Kawaguchi
    Shinichiro Fujimoto
    Kazuhisa Takamura
    Etsuro Kato
    Shoko Suda
    Rie Matsumori
    Makoto Hiki
    Kanako K. Kumamaru
    Hiroyuki Daida
    The International Journal of Cardiovascular Imaging, 2018, 34 : 465 - 474
  • [23] Movement of the Eustachian Tube During Sniffing in Patients With Patulous Eustachian Tube: Evaluation Using a 320-Row Area Detector CT Scanner
    Yoshioka, Satoshi
    Naito, Kensei
    Fujii, Naoko
    Katada, Kazuhiro
    OTOLOGY & NEUROTOLOGY, 2013, 34 (05) : 877 - 883
  • [24] Annular Flow in the Upper Esophageal Sphincter Demonstrated with Dynamic 320-row Area Detector Computed Tomography
    Inamoto, Yoko
    Saitoh, Eiichi
    Palmer, Jeffrey B.
    DYSPHAGIA, 2021, 36 (06) : 1088 - 1094
  • [25] Submillisievert imaging protocol using full reconstruction and advanced patient motion correction in 320-row area detector coronary CT angiography
    Kawaguchi, Yuko
    Fujimoto, Shinichiro
    Takamura, Kazuhisa
    Kato, Etsuro
    Suda, Shoko
    Matsumori, Rie
    Hiki, Makoto
    Kumamaru, Kanako K.
    Daida, Hiroyuki
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2018, 34 (03): : 465 - 474
  • [26] The usefulness of low radiation dose subtraction coronary computed tomography angiography for patients with calcification using 320-row area detector CT
    Takamura, Kazuhisa
    Fujimoto, Shinichiro
    Kawaguchi, Yuko
    Kato, Etsuro
    Aoshima, Chihiro
    Hiki, Makoto
    Kumamaru, Kanako K.
    Daida, Hiroyuki
    JOURNAL OF CARDIOLOGY, 2019, 73 (1-2) : 58 - 64
  • [27] The effect of bolus volume on laryngeal closure and UES opening in swallowing: Kinematic analysis using 320-row area detector CT study
    Shibata, S.
    Inamoto, Y.
    Saitoh, E.
    Kagaya, H.
    Aoyagi, Y.
    Ota, K.
    Akahori, R.
    Fujii, N.
    Palmer, J. B.
    Gonzalez-Fernandez, M.
    JOURNAL OF ORAL REHABILITATION, 2017, 44 (12) : 974 - 981
  • [28] Dynamic enhancement pattern of unstable coronary plaque: analysis by 320-row area detector computed tomography
    Kameyama, T.
    Ihori, H.
    Ohara, K.
    Nonomura, M.
    Misaki, T.
    Inoue, H.
    EUROPEAN HEART JOURNAL, 2015, 36 : 890 - 890
  • [29] Comparing subjective and objective image quality at two different radiation exposure ranges of the paranasal sinus CT examinations using a volumetric 320-row detector CT system
    Pirimoglu, Berhan
    Sade, Recep
    Sakat, Muhammed Sedat
    Ogul, Hayri
    Eren, Suat
    Kantarci, Mecit
    DENTOMAXILLOFACIAL RADIOLOGY, 2017, 46 (08)
  • [30] Feasibility of 320-row area detector CT coronary angiography using 40 mL of contrast material: assessment of image quality and diagnostic accuracy
    Rihyeon Kim
    Eun-Ah Park
    Whal Lee
    Jin Wook Chung
    European Radiology, 2016, 26 : 3802 - 3810