Annular Flow in the Upper Esophageal Sphincter Demonstrated with Dynamic 320-row Area Detector Computed Tomography

被引:2
|
作者
Inamoto, Yoko [1 ,2 ]
Saitoh, Eiichi [2 ]
Palmer, Jeffrey B. [3 ]
机构
[1] Fujita Hlth Univ, Sch Hlth Sci, Fac Rehabil, 1-98 Dengakugakubo, Toyoake, Aichi 4701192, Japan
[2] Fujita Hlth Univ, Sch Med, Dept Rehabil Med 1, Toyoake, Aichi, Japan
[3] Johns Hopkins Univ, Dept Phys Med & Rehabil, Baltimore, MD USA
关键词
D O I
10.1007/s00455-020-10241-9
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Understanding bolus flow patterns in swallowing (rheology, the study of flow) is fundamental to assessment and treatment of dysphagia. These patterns are complex and poorly understood. A liquid swallow is typically biphasic, including air, so the actual bolus has both liquid and gas phases. We report a novel observation of annular two-phase flow (a ring of liquid around a core of air) as thin liquids passed through the upper esophageal sphincter (UES). Dynamic CT was performed on 27 healthy asymptomatic volunteers swallowing liquid barium in a semi-reclining position. Each subject swallowed 3, 10, and 20 ml of either thin (14 subjects) or thick liquid (13 subjects). Sagittal and axial images were analyzed. Flow patterns in the UES were assessed on cross-sectional images. Annular flow was seen in the majority of subjects with thin liquid but few with thick liquid swallows. The percentage of Annular flow during UES opening was 3 ml 58%, 10 ml 58%, 20 ml 56% in thin and 3 ml 0%, 10 ml 4%, 20 ml 1% in thick. Annular flow was usually observed from the second or third frames after onset of UES opening. The other pattern, Plug flow was seldom seen with thin but was typical with thick liquid swallows. Annular flow was the most common pattern for thin liquids (but not thick liquids) passing through the UES. Annular flow has been defined as a liquid continuum adjacent to the channel wall with a gas continuum (core) in the center of the channel. The two regions are demarcated by a gas-liquid interface. Annular flow is typical for two-phase gas-liquid flow in a vertical or inclined channel. It results from the interaction of viscosity with cohesive and adhesive forces in the two phases. We infer that the difference in flow pattern between thin liquid-air and thick liquid-air boluses resulted from the differing magnitudes of viscous forces.
引用
收藏
页码:1088 / 1094
页数:7
相关论文
共 50 条
  • [1] Annular Flow in the Upper Esophageal Sphincter Demonstrated with Dynamic 320-row Area Detector Computed Tomography
    Yoko Inamoto
    Eiichi Saitoh
    Jeffrey B. Palmer
    Dysphagia, 2021, 36 : 1088 - 1094
  • [2] Evaluation of Pharyngoesophageal Segment Using 320-Row Area Detector Computed Tomography
    Wattanapan, Pattra
    Kagaya, Hitoshi
    Inamoto, Yoko
    Saitoh, Eiichi
    Shibata, Seiko
    Iida, Takatoshi
    ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 2018, 127 (12): : 888 - 894
  • [3] The dynamics of deglutition during head rotation using dynamic 320-row area detector computed tomography
    Kochi, Kazutaka
    Sei, Hirofumi
    Tanabe, Yuki
    Yasuda, Kazunori
    Kido, Teruhito
    Yamada, Hiroyuki
    Taguchi, Aki
    Hato, Naohito
    LARYNGOSCOPE INVESTIGATIVE OTOLARYNGOLOGY, 2023, 8 (03): : 746 - 753
  • [4] Dynamic enhancement pattern of unstable coronary plaque: analysis by 320-row area detector computed tomography
    Kameyama, T.
    Ihori, H.
    Ohara, K.
    Nonomura, M.
    Misaki, T.
    Inoue, H.
    EUROPEAN HEART JOURNAL, 2015, 36 : 890 - 890
  • [5] Usefulness of 320-Row Area Detector Computed Tomography for the Diagnosis of Cystic Falx Meningioma
    Tabuchi, Sadaharu
    Nakajima, Sadao
    CASE REPORTS IN ONCOLOGY, 2013, 6 (02): : 362 - 366
  • [6] Usefulness of 320-row area detector computed tomography for the diagnosis of congenital absence of portal vein
    Pan, Yuning
    Ren, Dawei
    Jiang, Maoqing
    Huang, Qiuli
    Li, Aijing
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2016, 9 (02): : 4790 - 4795
  • [7] Image Quality of Coronary Computed Tomography Angiography with 320-Row Area Detector Computed Tomography in Children with Congenital Heart Disease
    Tada, Akihiro
    Sato, Shuhei
    Kanie, Yuichiro
    Tanaka, Takashi
    Inai, Ryota
    Akagi, Noriaki
    Morimitsu, Yusuke
    Kanazawa, Susumu
    PEDIATRIC CARDIOLOGY, 2016, 37 (03) : 497 - 503
  • [8] Image quality of coronary computed tomography angiography with 320-Row area detector computed tomography in children with congenital heart disease
    Qin, Jie
    Cai, Songwang
    Peng, Lingrong
    Tang, Wenjie
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 68 (16) : C142 - C142
  • [9] Image Quality of Coronary Computed Tomography Angiography with 320-Row Area Detector Computed Tomography in Children with Congenital Heart Disease
    Akihiro Tada
    Shuhei Sato
    Yuichiro Kanie
    Takashi Tanaka
    Ryota Inai
    Noriaki Akagi
    Yusuke Morimitsu
    Susumu Kanazawa
    Pediatric Cardiology, 2016, 37 : 497 - 503
  • [10] Dynamic Enhancement Pattern is Different Between Unstable and Stable Coronary Plaque: Analysis With 320-Row Area Detector Computed Tomography
    Kameyama, Tomoki
    Ihori, Hiroyuki
    Ohara, Kazumasa
    Nonomura, Makoto
    Inoue, Hiroshi
    CIRCULATION, 2017, 136