Annular Flow in the Upper Esophageal Sphincter Demonstrated with Dynamic 320-row Area Detector Computed Tomography

被引:2
|
作者
Inamoto, Yoko [1 ,2 ]
Saitoh, Eiichi [2 ]
Palmer, Jeffrey B. [3 ]
机构
[1] Fujita Hlth Univ, Sch Hlth Sci, Fac Rehabil, 1-98 Dengakugakubo, Toyoake, Aichi 4701192, Japan
[2] Fujita Hlth Univ, Sch Med, Dept Rehabil Med 1, Toyoake, Aichi, Japan
[3] Johns Hopkins Univ, Dept Phys Med & Rehabil, Baltimore, MD USA
关键词
D O I
10.1007/s00455-020-10241-9
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Understanding bolus flow patterns in swallowing (rheology, the study of flow) is fundamental to assessment and treatment of dysphagia. These patterns are complex and poorly understood. A liquid swallow is typically biphasic, including air, so the actual bolus has both liquid and gas phases. We report a novel observation of annular two-phase flow (a ring of liquid around a core of air) as thin liquids passed through the upper esophageal sphincter (UES). Dynamic CT was performed on 27 healthy asymptomatic volunteers swallowing liquid barium in a semi-reclining position. Each subject swallowed 3, 10, and 20 ml of either thin (14 subjects) or thick liquid (13 subjects). Sagittal and axial images were analyzed. Flow patterns in the UES were assessed on cross-sectional images. Annular flow was seen in the majority of subjects with thin liquid but few with thick liquid swallows. The percentage of Annular flow during UES opening was 3 ml 58%, 10 ml 58%, 20 ml 56% in thin and 3 ml 0%, 10 ml 4%, 20 ml 1% in thick. Annular flow was usually observed from the second or third frames after onset of UES opening. The other pattern, Plug flow was seldom seen with thin but was typical with thick liquid swallows. Annular flow was the most common pattern for thin liquids (but not thick liquids) passing through the UES. Annular flow has been defined as a liquid continuum adjacent to the channel wall with a gas continuum (core) in the center of the channel. The two regions are demarcated by a gas-liquid interface. Annular flow is typical for two-phase gas-liquid flow in a vertical or inclined channel. It results from the interaction of viscosity with cohesive and adhesive forces in the two phases. We infer that the difference in flow pattern between thin liquid-air and thick liquid-air boluses resulted from the differing magnitudes of viscous forces.
引用
收藏
页码:1088 / 1094
页数:7
相关论文
共 50 条
  • [31] Computed Tomography Myocardial Perfusion Imaging With 320-Row Detector Computed Tomography Accurately Detects Myocardial Ischemia in Patients With Obstructive Coronary Artery Disease
    George, Richard T.
    Arbab-Zadeh, Armin
    Miller, Julie M.
    Vavere, Andrea L.
    Bengel, Frank M.
    Lardo, Albert C.
    Lima, Joao A. C.
    CIRCULATION-CARDIOVASCULAR IMAGING, 2012, 5 (03) : 333 - 340
  • [32] Questionable necessity of nitroglycerin for diagnostic coronary artery examination using 320-row multi-detector computed tomography
    Lu, Nan-Han
    Liu, Yi-Shan
    Liu, Ko-In
    Hsu, Shih-Yen
    Huang, Yung-Hui
    Sun, Cheuk-Kwan
    Chen, Tai-Been
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2020, 28 (05) : 989 - 999
  • [33] Early stage of chronic kidney disease develops coronary atherosclerosis but does not increase vulnerable plaques: usefulness of 320-row area detector computed tomography
    Kawai, H.
    Sarai, M.
    Harigaya, H.
    Motoyama, S.
    Hara, T.
    Naruse, H.
    Ozaki, Y.
    EUROPEAN HEART JOURNAL, 2010, 31 : 434 - 434
  • [34] Coronary artery-to-pulmonary artery fistula in adults: evaluation with 320-row detector computed tomography coronary angiography
    Hang, Kaibing
    Zhao, Guoli
    Su, Weiwei
    Bao, Guangjin
    Zhao, Qi
    Jiao, Zizhen
    Tian, Zhanqi
    Zhang, Hui
    Nie, Lin
    Luo, Rui
    Li, Lifang
    Huang, Min
    Shi, Lijing
    Li, Shuping
    ANNALS OF TRANSLATIONAL MEDICINE, 2021, 9 (18)
  • [35] The usefulness of subtraction coronary computed tomography angiography for in-stent restenosis assessment of patients with CoCr stent using 320-row area detector CT
    Li, Jian
    Guo, Man-Tao
    Yang, Xiao
    Gao, Fang
    Li, Na
    Huang, Ming-Gang
    MEDICINE, 2021, 100 (51) : E28345
  • [36] Tumour volume comparison between 16-row multi-detector computed tomography and 320-row area-detector computed tomography in patients with small lung tumours treated with stereotactic body radiotherapy: Effect of respiratory motion
    Iizuka, Yusuke
    Nakamura, Mitsuhiro
    Kozawa, Satoshi
    Mitsuyoshi, Takamasa
    Matsuo, Yukinori
    Mizowaki, Takashi
    EUROPEAN JOURNAL OF RADIOLOGY, 2019, 117 : 120 - 125
  • [37] Combined Adenosine Stress Perfusion and Coronary Angiography Using 320-Row Detector Dynamic Volume Computed Tomography in Patients with Suspected Coronary Artery Disease
    George, Richard T.
    Kitagawa, Kakuya
    Laws, Katherine
    Lardo, Albert C.
    Lima, Joao A.
    CIRCULATION, 2008, 118 (18) : S936 - S936
  • [38] History of cardiac computed tomography: single to 320-detector row multislice computed tomography
    Gregory S. Hurlock
    Hiroshi Higashino
    Teruhito Mochizuki
    The International Journal of Cardiovascular Imaging, 2009, 25 : 31 - 42
  • [39] History of cardiac computed tomography: single to 320-detector row multislice computed tomography
    Hurlock, Gregory S.
    Higashino, Hiroshi
    Mochizuki, Teruhito
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2009, 25 : 31 - 42
  • [40] Feasibility of 320-row multi-detector computed tomography angiography to assess bioabsorbable everolimus-eluting vascular scaffolds
    Asami M.
    Aoki J.
    Serruys P.W.
    Abizaid A.
    Saito S.
    Onuma Y.
    Kimura T.
    Simonton C.A.
    Tanabe K.
    Cardiovascular Intervention and Therapeutics, 2016, 31 (2) : 96 - 100