Repeatability, reproducibility, and agreement of three tonometers for measuring intraocular pressure in rabbits

被引:0
|
作者
Christian J. F. Bertens
Ralph J. S. van Mechelen
Tos T. J. M. Berendschot
Marlies Gijs
Jarno E. J. Wolters
Theo G. M. F. Gorgels
Rudy M. M. A. Nuijts
Henny J. M. Beckers
机构
[1] Maastricht University Medical Center+ (MUMC+),Department of Ophthalmology, University Eye Clinic Maastricht, School for Mental Health and Neuroscience (MHeNs)
[2] Chemelot Institute for Science and Technology (InSciTe),undefined
来源
Scientific Reports | / 11卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
The aim of this study was to evaluate repeatability, reproducibility, and agreement of three commonly used tonometers in animal research (TonoLab, TonoVet, and TonoPEN AVIA) in a cohort of 24 rabbits. Additionally, the impact of sedation on IOP was investigated in 21 New Zealand White rabbits with the TonoVet tonometer. Repeatability was determined using the coefficient of variation (CoV) for two observers. For the TonoLab (6.55%) and TonoVet (6.38%) the CoV was lower than for the TonoPEN AVIA (10.88%). The reproducibility was highest for the TonoVet (0.2 ± 3.3 mmHg), followed by the TonoLab (0 ± 12.89 mmHg) and lowest for the TonoPEN AVIA (− 1.48 ± 10.3 mmHg). The TonoLab and TonoVet showed the highest agreement (r = 0.85, R2 = 0.73). After sedation, a significant IOP reduction (often > 25%) was observed. Our results show that among the three tonometers tested, the TonoVet tonometer is best for use in rabbits while the TonoLab should be avoided. The impact of sedation on IOP was substantial and should be taken into account during experimentation.
引用
收藏
相关论文
共 50 条
  • [21] MEASURING INTRAOCULAR-PRESSURE IN RABBITS TY TELEMETRY
    MCLAREN, JW
    FITZSIMON, JS
    BRUBAKER, RF
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1995, 36 (04) : S411 - S411
  • [22] Influence of Axial Length on Intraocular Pressure Measurement With Three Tonometers in Childhood Glaucoma
    Mendez-Hernandez, Carmen
    Arribas-Pardo, Paula
    Sanchez Jean, Ruben
    Garcia-Feljoo, Julian
    JOURNAL OF PEDIATRIC OPHTHALMOLOGY & STRABISMUS, 2020, 57 (01) : 27 - 32
  • [23] Measurement of intraocular pressure and calibration of modern tonometers
    Schwenteck, T
    PTB-MITTEILUNGEN, 2001, 111 (01): : 32 - 33
  • [24] CALIBRATION OF TONOMETERS AND TRUE INTRAOCULAR-PRESSURE
    FRANCOIS, J
    VANCEA, P
    VANDEKERCKHOVE, R
    OPHTHALMOLOGICA, 1973, 167 (01) : 27 - 48
  • [25] Intraocular pressure measurement: Comparison of two tonometers
    Bonnet, L.
    Bellebeau, F.
    Crettet, N.
    Voute, H.
    Descotes, J.
    TOXICOLOGY LETTERS, 2005, 158 : S78 - S79
  • [26] Intraocular Pressure Measurements by Three Different Tonometers in Children with Aphakic Glaucoma and a Thick Cornea
    Razeghinejad, Mohammad Reza
    Salouti, Ramin
    Khalili, Mohammad Reza
    IRANIAN JOURNAL OF MEDICAL SCIENCES, 2014, 39 (01) : 11 - 19
  • [27] Latanoprost treatment differentially affects intraocular pressure readings obtained with three different tonometers
    Sanchez-Barahona, Cristina
    Bolivar, Gema
    Katsanos, Andreas
    Teus, Miguel A.
    ACTA OPHTHALMOLOGICA, 2019, 97 (08) : E1112 - E1115
  • [28] Repeatability and Reproducibility of Intraocular Pressure and Dynamic Corneal Response Parameters Assessed by the Corvis ST
    Lopes, Bernardo T.
    Roberts, Cynthia J.
    Elsheikh, Ahmed
    Vinciguerra, Riccardo
    Vinciguerra, Paolo
    Reisdorf, Sven
    Berger, Stefanie
    Koprowski, Robert
    Ambrosio, Renato, Jr.
    JOURNAL OF OPHTHALMOLOGY, 2017, 2017
  • [29] Agreement of three tonometers with Goldmann Applanation Tonometry (GAT)
    Campbell, Peter
    Edgar, David
    Shah, Rakhee
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [30] Assessing Measurement System Agreement in the Presence of Reproducibility and Repeatability
    Ahmadi Nadi, Adel
    Steiner, Stefan H.
    Stevens, Nathaniel T.
    TECHNOMETRICS, 2024, 66 (03) : 319 - 330