Repeatability, reproducibility, and agreement of three tonometers for measuring intraocular pressure in rabbits

被引:0
|
作者
Christian J. F. Bertens
Ralph J. S. van Mechelen
Tos T. J. M. Berendschot
Marlies Gijs
Jarno E. J. Wolters
Theo G. M. F. Gorgels
Rudy M. M. A. Nuijts
Henny J. M. Beckers
机构
[1] Maastricht University Medical Center+ (MUMC+),Department of Ophthalmology, University Eye Clinic Maastricht, School for Mental Health and Neuroscience (MHeNs)
[2] Chemelot Institute for Science and Technology (InSciTe),undefined
来源
Scientific Reports | / 11卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
The aim of this study was to evaluate repeatability, reproducibility, and agreement of three commonly used tonometers in animal research (TonoLab, TonoVet, and TonoPEN AVIA) in a cohort of 24 rabbits. Additionally, the impact of sedation on IOP was investigated in 21 New Zealand White rabbits with the TonoVet tonometer. Repeatability was determined using the coefficient of variation (CoV) for two observers. For the TonoLab (6.55%) and TonoVet (6.38%) the CoV was lower than for the TonoPEN AVIA (10.88%). The reproducibility was highest for the TonoVet (0.2 ± 3.3 mmHg), followed by the TonoLab (0 ± 12.89 mmHg) and lowest for the TonoPEN AVIA (− 1.48 ± 10.3 mmHg). The TonoLab and TonoVet showed the highest agreement (r = 0.85, R2 = 0.73). After sedation, a significant IOP reduction (often > 25%) was observed. Our results show that among the three tonometers tested, the TonoVet tonometer is best for use in rabbits while the TonoLab should be avoided. The impact of sedation on IOP was substantial and should be taken into account during experimentation.
引用
收藏
相关论文
共 50 条
  • [41] Comparison of simultaneous readings of intraocular pressure in rabbits using Perkins handheld, Tono-Pen XL, and TonoVet tonometers
    Kalesnykas, Giedrius
    Uusitalo, Hannu
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2007, 245 (05) : 761 - 762
  • [42] Assessment of agreement between molar landmarks: Repeatability, reproducibility, and comparability
    Varlik, Selin Kale
    Uzuner, Deniz
    Tortop, Tuba
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2016, 150 (03) : 504 - 510
  • [43] How to Measure Intraocular Pressure: An Updated Review of Various Tonometers
    Brusini, Paolo
    Salvetat, Maria Letizia
    Zeppieri, Marco
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (17)
  • [44] Comparison of simultaneous readings of intraocular pressure in rabbits using Perkins handheld, Tono-Pen XL, and TonoVet tonometers
    Giedrius Kalesnykas
    Hannu Uusitalo
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2007, 245 : 761 - 762
  • [45] Repeatability and Reproducibility for Intraocular Pressure Measurement by Dynamic Contour, Ocular Response Analyzer, and Goldmann Applanation Tonometry
    Sullivan-Mee, Michael
    Gerhardt, Gretchen
    Halverson, Kathy D.
    Qualls, Clifford
    JOURNAL OF GLAUCOMA, 2009, 18 (09) : 666 - 673
  • [46] INTRAOCULAR FEEDBACK MECHANISMS OF INTRAOCULAR PRESSURE IN RABBITS
    VALEBJORG, H
    ACTA OPHTHALMOLOGICA, 1970, 48 (04) : 809 - +
  • [47] Comparison of three methodologies for measuring intraocular pressure in healthy cats
    Ricci, Claudia Lizandra
    Passareli, Joao Victor Goulart Consoni
    Nascimento, Felipe Franco
    Kanashiro, Glaucia Prada
    Zulim, Luis Felipe da Costa
    Giuffrida, Rogerio
    Andrade, Silvia Franco
    VETERINARY WORLD, 2024, 17 (08) : 1803 - 1809
  • [48] Measuring intraocular pressure
    McDonald, J. E. Jay, II
    ANNALS OF OPHTHALMOLOGY, 2006, 38 (01) : 5 - 8
  • [49] Measuring intraocular pressure
    Okafor, Kingsley C.
    Brandt, James D.
    CURRENT OPINION IN OPHTHALMOLOGY, 2015, 26 (02) : 103 - 109
  • [50] Comparison of Intraocular Pressure Measurements Obtained Using Three Tonometers after Descemet Membrane Stripping Endothelial Keratoplasty
    Choi, Jeong Mun
    Kang, Yong Koo
    Kim, Hong Kyun
    Kim, Dai Woo
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2023, 64 (07): : 605 - 612