Speckle reduction in double-pass retinal images

被引:0
|
作者
Donatus Halpaap
Carlos E. García-Guerra
Meritxell Vilaseca
Cristina Masoller
机构
[1] Universitat Politècnica de Catalunya,Departament de Física
[2] Universitat Politècnica de Catalunya,Centre de Desenvolupament de Sensors, Instrumentació i Sistemes
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
The double pass (DP) technique quantifies the optical quality of the eye by measuring its point spread function. The low reflectivity of the retina requires the use of a high-brightness, point-like illumination source, and thus, DP systems use laser diodes (LDs). However, LDs light produces speckle, and a low-cost solution to reduce speckle is to include a vibrating mirror in the beam path. With the goal of finding an all-optical solution, here we perform a comparative study of the amount of speckle produced by three semiconductor light sources: an LD, a light emitting diode (LED), and a superluminescent diode (SLED). We also compare the results with the speckle reduction that is obtained with a vibrating mirror. We find that the SLED is a good alternative to LD illumination, as the amount of speckle in the image is almost as low as that obtained with an LD and a vibrating mirror in the beam path.
引用
收藏
相关论文
共 50 条
  • [31] DOUBLE-PASS MONOCHROMATOR FOR FAR INFRARED
    NOLT, IG
    SIEVERS, AJ
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1965, 55 (11) : 1586 - &
  • [32] Neuberger's double-pass algorithm
    Chiu, TW
    Hsieh, TH
    PHYSICAL REVIEW E, 2003, 68 (06):
  • [33] Double-pass quantum volume hologram
    Vasilyev, Denis V.
    Sokolov, Ivan V.
    PHYSICAL REVIEW A, 2011, 83 (05):
  • [34] THE REVERSIBILITY OF THE EYES OPTICAL-SYSTEM IN DOUBLE-PASS MEASUREMENTS OF RETINAL IMAGE QUALITY
    ARTAL, P
    IGLESIAS, I
    LOPEZ, N
    GREEN, DG
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1995, 36 (04) : S188 - S188
  • [35] Reconstruction of the point-spread function of the human eye from two double-pass retinal images by phase-retrieval algorithms
    Iglesias, Ignacio
    Lopez-Gil, Norberto
    Artal, Pablo
    Journal of the Optical Society of America A: Optics and Image Science, and Vision, 1998, 15 (02):
  • [36] A DOUBLE-BEAM DOUBLE-PASS INFRARED SPECTROMETER
    COLE, ARH
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1953, 43 (09) : 807 - 808
  • [37] Quantifying ocular scattering in cataract patients using wide angle double-pass images
    Martinez-Roda, Juan A.
    Vilaseca, Meritxell
    Salvador, Marta
    Fons, Mariona
    Herrera, Olga D.
    Salvador, Antoni
    Pujol, Jaume
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [38] Reconstruction of the point-spread function of the human eye from two double-pass retinal images by phase-retrieval algorithms
    Iglesias, I
    Lopez-Gil, N
    Artal, P
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1998, 15 (02): : 326 - 339
  • [39] EXPERIMENTS ON SINGLE-PASS AND DOUBLE-PASS BIREFRIGENT NETWORKS
    YARBOROUGH, JM
    AMMANN, EO
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1968, 58 (06) : 776 - +
  • [40] Incoherent Light Sources for Speckle Reduction in Double Pass Ocular Imaging
    Halpaap, Donatus
    Vilaseca, Meritxell
    Masoller, Cristina
    OPTICAL COHERENCE IMAGING TECHNIQUES AND IMAGING IN SCATTERING MEDIA II, 2017, 10416