Reconstruction of the point-spread function of the human eye from two double-pass retinal images by phase-retrieval algorithms

被引:0
|
作者
Iglesias, Ignacio
Lopez-Gil, Norberto
Artal, Pablo
机构
关键词
D O I
暂无
中图分类号
学科分类号
摘要
引用
下载
收藏
相关论文
共 16 条
  • [1] Reconstruction of the point-spread function of the human eye from two double-pass retinal images by phase-retrieval algorithms
    Iglesias, I
    Lopez-Gil, N
    Artal, P
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1998, 15 (02): : 326 - 339
  • [2] Reconstruction of the point-spread function of the human eye using a new phase-retrieval algorithm
    Iida, Yukio
    Shibutani, Masahiro
    Kobayashi, Katsuhiko
    Ohnuma, Kazuhiko
    Miyake, Yoichi
    Noda, Toru
    OPTICAL REVIEW, 2006, 13 (02) : 87 - 92
  • [3] Reconstruction of the Point-Spread Function of the Human Eye Using a New Phase-Retrieval Algorithm
    Yukio Iida
    Masahiro Shibutani
    Katsuhiko Kobayashi
    Kazuhiko Ohnuma
    Yoichi Miyake
    Toru Noda
    Optical Review, 2006, 13 : 87 - 92
  • [4] PHASE-TRANSFER AND POINT-SPREAD FUNCTION OF THE HUMAN EYE DETERMINED BY A NEW ASYMMETRIC DOUBLE-PASS METHOD
    NAVARRO, R
    LOSADA, MA
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1995, 12 (11): : 2385 - 2392
  • [5] Point spread function of the human eye obtained by a dual double-pass method
    Losada, MA
    Navarro, R
    PURE AND APPLIED OPTICS, 1998, 7 (01): : L7 - L13
  • [6] Combined effect of wavelength and polarization in double-pass retinal images in the human eye
    Bueno, Juan M.
    Perez, Guillermo M.
    VISION RESEARCH, 2010, 50 (23) : 2439 - 2444
  • [7] Measured double-pass intensity point-spread function after adaptive optics correction of ocular aberrations
    Logean, Eric
    Dalimier, Eugenie
    Dainty, Chris
    OPTICS EXPRESS, 2008, 16 (22): : 17348 - 17357
  • [8] New phase-retrieval algorithm for reconstructing point spread function in human eyes
    Kobayashi, Kastuhiko
    Iida, Yukio
    Ohnuma, Kazuhiko
    Noda, Toru
    OPHTHALMIC TECHNOLOGIES XVII, 2007, 6426
  • [9] STABLE ITERATIVE APPROACH TO PHASE RETRIEVAL FROM POINT-SPREAD FUNCTION DATA
    BARAKAT, R
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1979, 69 (10) : 1467 - 1467
  • [10] Effect of pupil diameter on the retinal image quality calculated from double-pass point-spread-function measurements
    Borja, D
    Manns, F
    Takeuchi, G
    Shibutani, M
    Yoo, ES
    Lee, Y
    Culbertson, W
    Kobayashi, K
    Parel, J