Speckle reduction in double-pass retinal images

被引:0
|
作者
Donatus Halpaap
Carlos E. García-Guerra
Meritxell Vilaseca
Cristina Masoller
机构
[1] Universitat Politècnica de Catalunya,Departament de Física
[2] Universitat Politècnica de Catalunya,Centre de Desenvolupament de Sensors, Instrumentació i Sistemes
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
The double pass (DP) technique quantifies the optical quality of the eye by measuring its point spread function. The low reflectivity of the retina requires the use of a high-brightness, point-like illumination source, and thus, DP systems use laser diodes (LDs). However, LDs light produces speckle, and a low-cost solution to reduce speckle is to include a vibrating mirror in the beam path. With the goal of finding an all-optical solution, here we perform a comparative study of the amount of speckle produced by three semiconductor light sources: an LD, a light emitting diode (LED), and a superluminescent diode (SLED). We also compare the results with the speckle reduction that is obtained with a vibrating mirror. We find that the SLED is a good alternative to LD illumination, as the amount of speckle in the image is almost as low as that obtained with an LD and a vibrating mirror in the beam path.
引用
收藏
相关论文
共 50 条
  • [21] A double-pass fundus reflection model for efficient single retinal image enhancement
    Zhang, Shuhe
    Webers, Carroll A. B.
    Berendschot, Tos T. J. M.
    SIGNAL PROCESSING, 2022, 192
  • [22] Double-pass measurements of retinal image quality in monofocal contact lens wearers
    Torrents, A
    Gispets, J
    Pujol, J
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 1997, 17 (04) : 357 - 366
  • [23] A double-pass fundus reflection model for efficient single retinal image enhancement
    Zhang, Shuhe
    Carroll, Webers
    Berendschot, Tos T. J. M.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2021, 62 (08)
  • [24] Quantification of forward scattering based on the analysis of double-pass images in the frequency domain
    Martinez-Roda, Joan A.
    Garcia-Guerra, Carlos E.
    Diaz-Douton, Fernando
    Pujol, Jaume
    Salvador, Antoni
    Vilaseca, Meritxell
    ACTA OPHTHALMOLOGICA, 2019, 97 (07) : E1019 - E1026
  • [25] Objective Assessment of Visual Quality and Ocular Scattering Based on Double-pass Retinal Images in Refractive-surgery Patients and Emmetropes
    Kim, Jeong-mee
    CURRENT OPTICS AND PHOTONICS, 2019, 3 (06) : 597 - 604
  • [26] Double-pass hybrid resonator for COIL
    Pargmann, Carsten
    Hall, Thomas
    Duschek, Frank
    Gruenewald, Karin M.
    Handke, Juergen
    XVII INTERNATIONAL SYMPOSIUM ON GAS FLOW, CHEMICAL LASERS, AND HIGH-POWER LASERS, 2009, 7131
  • [27] Double-pass point diffraction interferometer
    Kihm, Hagyong
    Lee, Yun-Woo
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2010, 21 (10)
  • [28] Double-pass grating imaging spectrometer
    Meng, Xin
    Yang, Zhongming
    Du, Jinyu
    Fan, Guobin
    CHINESE OPTICS LETTERS, 2019, 17 (01)
  • [29] Repeatability of measurements with a double-pass system
    Saad, Alain
    Saab, Marc
    Gatinel, Damien
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (01): : 28 - 33
  • [30] Double-pass grating imaging spectrometer
    孟鑫
    杨忠明
    杜近宇
    范国斌
    ChineseOpticsLetters, 2019, 17 (01) : 43 - 46