Raising the reliability of water conditioning systems at the Sakhalin State Regional Power Plant

被引:0
|
作者
Slesarenko V.V. [1 ]
Avdeev L.E. [2 ]
Stavniichuk L.A. [2 ]
机构
[1] Center for Boiler Updating, Far-East State Engineering University
关键词
Evaporating units; Qualityof water and steam; Reverse osmosis plants; Water balance; Water conditioning;
D O I
10.1007/s10749-006-0030-8
中图分类号
学科分类号
摘要
Results of a study of the water conditioning unit of the Sakhalin SRPP are presented. Analysis of the operating, regulating, and design documentation and of computations of the flow diagram has shown that a number of measures should be taken for stabilizing the water chemistry of the boilers and producing steam with parameters meeting the scheduled requirements. Variants of updating the WCU are considered, which are expected to raise the reliability of the system of water conditioning due to the use of membrane reverse osmosis plants in the water desalination system. © Springer Science+Business Media, Inc. 2006.
引用
收藏
页码:109 / 112
页数:3
相关论文
共 50 条
  • [21] Reliability in Multi-regional Power Systems: Capacity Adequacy and the Role of Interconnectors
    Hagspiel, Simeon
    Knaut, Andreas
    Peter, Jakob
    ENERGY JOURNAL, 2018, 39 (05): : 183 - 203
  • [22] A Hybrid Reliability Model Using Generalized Renewal Processes for Predictive Maintenance in Nuclear Power Plant Circulating Water Systems
    Spangler, Ryan M.
    Agarwal, Vivek
    Cole, Daniel G.
    IEEE ACCESS, 2023, 11 : 136726 - 136740
  • [23] VIR-Process of Coal Firing at the Ryazanskaya State Regional Power Plant
    O. Yu. Gurylev
    I. V. Polikarpov
    F. Z. Finker
    Power Technology and Engineering, 2003, 37 (6) : 366 - 371
  • [24] REGIONAL SITING SURVEY FOR THERMAL POWER-PLANT SITES IN STATE OF OHIO
    ELKINS, ML
    DINUNNO, JJ
    MORGAN, PV
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1974, 19 : 42 - 46
  • [25] The use of sodium hydroxoaluminate in water conditioning for cooling systems in industry and power engineering
    I. N. Makarenko
    T. A. Shablii
    T. V. Krysenko
    Journal of Water Chemistry and Technology, 2009, 31 : 310 - 315
  • [26] Water-cooled air-conditioning systems for energy and power saving
    Suri, R.K.
    Al-Marafie, A.M.R.
    Maheshwari, G.P.
    International Journal of Ambient Energy, 1989, 10 (03) : 123 - 128
  • [27] The use of sodium hydroxoaluminate in water conditioning for cooling systems in industry and power engineering
    Makarenko, I. N.
    Shablii, T. A.
    Krysenko, T. V.
    JOURNAL OF WATER CHEMISTRY AND TECHNOLOGY, 2009, 31 (05) : 310 - 315
  • [28] Troitsk State Regional Electric Power Station is the leading power plant in power industry in Southern Ural region
    Rybka, V.I.
    Energetik, 2001, (11): : 30 - 33
  • [29] Dynamic reliability analysis framework for passive safety systems of Nuclear Power Plant
    Tripathi, A. Manish
    Singh, B. Lalit Kumar
    Singh, C. Suneet
    ANNALS OF NUCLEAR ENERGY, 2020, 140
  • [30] Real-time reliability index of a steam power plant: a systems approach
    Mohan, M.
    Gandhi, O. P.
    Agrawal, V. P.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 2008, 222 (A4) : 355 - 369