Trace Elemental Analysis of Commercial Bottled Drinking Water by a Portable Total Reflection X-ray Fluorescence Spectrometer

被引:0
|
作者
Shinsuke Kunimura
Jun Kawai
机构
[1] Kyoto University,Department of Materials Science and Engineering
来源
Analytical Sciences | 2007年 / 23卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
A portable total reflection X-ray fluorescence spectrometer was applied to commercial bottled drinking water containing 62 ppb (μg/L) V, 7.5 ppm (mg/L) Ca, and 1 ppm K. A dry residue, prepared by repeated pipetting and drying a 20 μL portion of drinking water on a sample holder six times, and another dry residue, prepared by pipetting and drying a 120 μL portion of the drinking water, were measured. The size of the dry residue of the drinking water was reduced by repeating the pipetting and drying. Calcium and potassium were easily detected in these two dry residues. Vanadium was detected in the dry residue prepared by repeated pipetting and drying. Vanadium, calcium, and potassium were quantified by using an internal standard, and the average quantified concentrations of V, Ca, and K were 91 ppb, 8.2 ppm, and 1.5 ppm, respectively. Although these quantified concentrations deviated from the certified concentrations (62 ppb of V, 7.5 ppm of Ca, and 1 ppm of K), it was possible for this portable spectrometer to estimate approximate concentrations.
引用
收藏
页码:1185 / 1188
页数:3
相关论文
共 50 条
  • [1] Trace elemental analysis of commercial bottled drinking water by a portable total reflection X-ray fluorescence spectrometer
    Kunimura, Shinsuke
    Kawai, Jun
    [J]. ANALYTICAL SCIENCES, 2007, 23 (10) : 1185 - 1188
  • [2] Application of a Portable Total Reflection X-Ray Fluorescence Spectrometer to a Trace Elemental Analysis of Wines
    Kunimura, Shinsuke
    Kawai, Jun
    [J]. BUNSEKI KAGAKU, 2009, 58 (12) : 1041 - 1045
  • [3] Trace Elemental Analysis of High Salinity Solutions Using a Portable Total Reflection X-ray Fluorescence Spectrometer
    Sugawara, Yugo
    Kunimura, Shinsuke
    [J]. BUNSEKI KAGAKU, 2017, 66 (08) : 585 - 589
  • [4] Trace elemental determination by portable total reflection X-ray fluorescence spectrometer with low wattage X-ray tube
    Kunimura, Shinsuke
    Kawai, Jun
    [J]. X-RAY SPECTROMETRY, 2013, 42 (03) : 171 - 173
  • [5] Optimization of a glancing angle for simultaneous trace elemental analysis by using a portable total reflection X-ray fluorescence spectrometer
    Kunimura, Shinsuke
    Watanabe, Daisuke
    Kawai, Jun
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2009, 64 (03) : 288 - 290
  • [6] Trace Elemental Determination Using a Portable Total Reflection X-Ray Fluorescence Spectrometer with a Collodion Film Sample Holder
    Shinsuke Kunimura
    Tomoki Shinkai
    [J]. Analytical Sciences, 2017, 33 : 635 - 637
  • [7] Trace Elemental Determination Using a Portable Total Reflection X-Ray Fluorescence Spectrometer with a Collodion Film Sample Holder
    Kunimura, Shinsuke
    Shinkai, Tomoki
    [J]. ANALYTICAL SCIENCES, 2017, 33 (05) : 635 - 638
  • [8] Measurement of Trace Amount of Cadmium Using a Portable Total Reflection X-Ray Fluorescence Spectrometer
    Kunimura, Shinsuke
    Amagasu, Katsuyuki
    [J]. ISIJ INTERNATIONAL, 2015, 55 (12) : 2697 - 2699
  • [9] Improvement in a Method for Trace Element Analysis Method Using a Portable Total Reflection X-ray Fluorescence Spectrometer
    Kunimura, Shinsuke
    Sugawara, Yugo
    Tokuoka, Yoshie
    Aono, Umina
    Sugioka, Taishiro
    Fukuroi, Yuka
    Terada, Shuichiro
    [J]. BUNSEKI KAGAKU, 2019, 68 (05) : 325 - 332
  • [10] Multi-Element Analysis by Portable Total Reflection X-ray Fluorescence Spectrometer
    Ying Liu
    Susumu Imashuku
    Jun Kawai
    [J]. Analytical Sciences, 2013, 29 : 793 - 797