Pulse-Shape Analysis and position resolution in highly segmented HPGe AGATA detectors

被引:0
|
作者
L. Lewandowski
P. Reiter
B. Birkenbach
B. Bruyneel
E. Clement
J. Eberth
H. Hess
C. Michelagnoli
H. Li
R. M. Perez-Vidal
M. Zielinska
机构
[1] University of Cologne,Instituto de Fisica Corpuscular
[2] Institut für Kernphysik,undefined
[3] Grand Accélérateur National d’Ions Lourds,undefined
[4] CSIC-Universitat de Valencia,undefined
[5] CEA Saclay,undefined
[6] Service de Physique Nucleaire,undefined
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
The performance of the Pulse-Shape Analysis (PSA) in AGATA HPGe detectors was investigated and improved employing a γ\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$\gamma$\end{document}-ray source measurement based on e+e-\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$ e^{+}e^{-}$\end{document} annihilation radiation after decays of 22Na by β+\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$ \beta^{+}$\end{document} decay. The first interaction positions of the two 511keV γ\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$\gamma$\end{document} rays were determined and the connecting line of these two positions was compared to the known source position as a measure for the PSA performance. The position resolution and its dependence on the PSA parameters were investigated by varying most relevant input quantities: the charge carrier mobility of the holes, the response of the employed measuring electronics especially the preamplifier rise time. The relative statistical weight of charge signals and transient signals was scrutinized. The optimal distance metric of the grid-search algorithm and its impact on the position resolution were determined.
引用
收藏
相关论文
共 50 条
  • [21] Improved energy resolution of highly segmented HPGe detectors by noise reduction
    Wiens, A.
    Birkenbach, B.
    Bruyneel, B.
    Eberth, J.
    Hess, H.
    Pascovici, Gh
    Reiter, P.
    Bazzacco, D.
    Farnea, E.
    Michelagnoli, C.
    Recchia, F.
    EUROPEAN PHYSICAL JOURNAL A, 2013, 49 (04): : 1 - 10
  • [22] Experimental determination of reference pulses for highly segmented HPGe detectors and application to Pulse Shape Analysis used in γ-ray tracking arrays
    Li, H. J.
    Ljungvall, J.
    Michelagnoli, C.
    Clement, E.
    Dudouet, J.
    Desesquelles, P.
    Lopez-Martens, A.
    de France, G.
    EUROPEAN PHYSICAL JOURNAL A, 2018, 54 (11):
  • [23] Response of AGATA segmented HPGe detectors to gamma rays up to 15.1 MeV
    Crespi, F. C. L.
    Avigo, R.
    Camera, F.
    Akkoyun, S.
    Atac, A.
    Bazzacco, D.
    Bellato, M.
    Benzoni, G.
    Blasi, N.
    Bortolato, D.
    Bottoni, S.
    Bracco, A.
    Brambilla, S.
    Bruyneel, B.
    Ceruti, S.
    Ciemala, M.
    Coelli, S.
    Eberth, J.
    Fanin, C.
    Farnea, E.
    Gadea, A.
    Giaz, A.
    Gottardo, A.
    Hess, H.
    Kmiecik, M.
    Leoni, S.
    Maj, A.
    Mengoni, D.
    Michelagnoli, C.
    Million, B.
    Montanari, D.
    Nicolini, R.
    Pellegri, L.
    Recchia, F.
    Reiter, P.
    Riboldi, S.
    Ur, C. A.
    Vandone, V.
    Valiente-Dobon, J. J.
    Wieland, O.
    Wiens, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 705 : 47 - 54
  • [24] Crosstalk corrections for improved energy resolution with highly segmented HPGe-detectors
    Bruyneel, Bart
    Reiter, Peter
    Wiens, Andreas
    Eberth, Juergen
    Hess, Herbert
    Pascovici, Gheorghe
    Warr, Nigel
    Aydin, Sezgin
    Bazzacco, Dino
    Recchia, Francesco
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 608 (01): : 99 - 106
  • [25] BACKGROUND RECOGNITION IN GERMANIUM DETECTORS BY PULSE-SHAPE ANALYSIS
    PETRY, F
    NUCLEAR PHYSICS B, 1994, : 391 - 393
  • [26] Simulations using the pulse shape comparison scanning technique on an AGATA segmented HPGe gamma-ray detector
    De Canditiis B.
    Duchêne G.
    European Physical Journal A, 2020, 56 (10):
  • [27] BACKGROUND RECOGNITION IN GERMANIUM DETECTORS BY PULSE-SHAPE ANALYSIS
    PETRY, F
    PROGRESS IN PARTICLE AND NUCLEAR PHYSICS, VOL 32: NEUTRINOS IN COSMOLOGY, ASTRO, PARTICLE AND NUCLEAR PHYSICS, 1994, 32 : 281 - 283
  • [28] BACKGROUND RECOGNITION IN GE DETECTORS BY PULSE-SHAPE ANALYSIS
    PETRY, F
    PIEPKE, A
    STRECKER, H
    KLAPDORKLEINGROTHAUS, HV
    BALYSH, A
    BELYAEV, ST
    DEMEHIN, A
    GUROV, A
    KONDRATENKO, I
    KOTELNIKOV, D
    LEBEDEV, VI
    LANDIS, D
    MADDEN, N
    PEHL, RH
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 332 (1-2): : 107 - 112
  • [29] Simulation and analysis of pulse shapes from highly segmented HPGe detectors for the γ-ray tracking array MARS
    Kröll, T
    Bazzacco, D
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 463 (1-2): : 227 - 249
  • [30] Response of AGATA Segmented HPGe Detectors to Gamma-Rays up to 15.1 MeV
    Crespi, F. C. L.
    Avigo, R.
    Camera, F.
    Benzoni, G.
    Blasi, N.
    Bottoni, S.
    Bracco, A.
    Brambilla, S.
    Casati, P.
    Coniglio, F.
    Corsi, A.
    Giaz, A.
    Leoni, S.
    Million, B.
    Nicolini, R.
    Pellegri, L.
    Riboldi, S.
    Vandone, V.
    Wieland, O.
    Akkoyun, S.
    Atac, A.
    Bazzacco, D.
    Bellato, M.
    Bortolato, D.
    Calore, E.
    Ciemala, M.
    Farnea, E.
    Gadea, A.
    Gottardo, A.
    Kmiecik, M.
    Maj, A.
    Mengoni, D.
    Michelagnoli, C.
    Montanari, D.
    Napoli, D. R.
    Nyberg, J.
    Recchia, F.
    Sahin, E.
    Soderstrom, P. -A.
    Ur, C.
    Dobon, J. J. Valiente
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 1147 - 1149