Pulse-Shape Analysis and position resolution in highly segmented HPGe AGATA detectors

被引:0
|
作者
L. Lewandowski
P. Reiter
B. Birkenbach
B. Bruyneel
E. Clement
J. Eberth
H. Hess
C. Michelagnoli
H. Li
R. M. Perez-Vidal
M. Zielinska
机构
[1] University of Cologne,Instituto de Fisica Corpuscular
[2] Institut für Kernphysik,undefined
[3] Grand Accélérateur National d’Ions Lourds,undefined
[4] CSIC-Universitat de Valencia,undefined
[5] CEA Saclay,undefined
[6] Service de Physique Nucleaire,undefined
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
The performance of the Pulse-Shape Analysis (PSA) in AGATA HPGe detectors was investigated and improved employing a γ\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$\gamma$\end{document}-ray source measurement based on e+e-\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$ e^{+}e^{-}$\end{document} annihilation radiation after decays of 22Na by β+\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$ \beta^{+}$\end{document} decay. The first interaction positions of the two 511keV γ\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$\gamma$\end{document} rays were determined and the connecting line of these two positions was compared to the known source position as a measure for the PSA performance. The position resolution and its dependence on the PSA parameters were investigated by varying most relevant input quantities: the charge carrier mobility of the holes, the response of the employed measuring electronics especially the preamplifier rise time. The relative statistical weight of charge signals and transient signals was scrutinized. The optimal distance metric of the grid-search algorithm and its impact on the position resolution were determined.
引用
收藏
相关论文
共 50 条
  • [31] Improvement of HPGe Detectors Timing Using Pulse Shape Analysis
    Crespi, F. C. L.
    Vandone, V.
    Brambilla, S.
    Camera, F.
    Million, B.
    Riboldi, S.
    Wieland, O.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 2121 - +
  • [32] Correction for hole trapping in AGATA detectors using pulse shape analysis
    Bruyneel, B.
    Birkenbach, B.
    Eberth, J.
    Hess, H.
    Pascovici, Gh.
    Reiter, P.
    Wiens, A.
    Bazzacco, D.
    Farnea, E.
    Michelagnoli, C.
    Recchia, F.
    EUROPEAN PHYSICAL JOURNAL A, 2013, 49 (05): : 1 - 9
  • [33] Characterization of a HPGe Segmented Detector Position Response Using Pulse Shape Comparison Techniques
    Crespi, F. C. L.
    Vandone, V.
    Brambilla, S.
    Camera, F.
    Million, B.
    Wieland, O.
    Bortolato, D.
    Recchia, F.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 1406 - +
  • [34] HPGe detectors timing using pulse shape analysis techniques
    Crespi, F. C. L.
    Vandone, V.
    Brambilla, S.
    Camera, F.
    Million, B.
    Riboldi, S.
    Wieland, O.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 620 (2-3): : 299 - 304
  • [35] Correction for hole trapping in AGATA detectors using pulse shape analysis
    B. Bruyneel
    B. Birkenbach
    J. Eberth
    H. Hess
    Gh. Pascovici
    P. Reiter
    A. Wiens
    D. Bazzacco
    E. Farnea
    C. Michelagnoli
    F. Recchia
    The European Physical Journal A, 2013, 49
  • [36] PULSE-SHAPE ANALYSIS FOR GERMANIUM DETECTORS USED IN DM SEARCHES
    SAGDEEV, IR
    DRUKIER, AK
    WELSH, DJ
    KLIMENKO, AA
    OSETROV, SB
    SMOLNIKOV, AA
    NUCLEAR PHYSICS B, 1994, : 175 - 179
  • [37] RESOLUTION IMPROVEMENT IN CDTE GAMMA-DETECTORS USING PULSE-SHAPE DISCRIMINATION
    JONES, LT
    WOOLLAM, PB
    NUCLEAR INSTRUMENTS & METHODS, 1975, 124 (02): : 591 - 595
  • [38] PULSE-SHAPE DISCRIMINATION WITH SURFACE BARRIER DETECTORS
    EMMERICH, WD
    FRANK, K
    HOFMANN, A
    DITTNER, A
    KLEIN, JW
    STOCK, R
    NUCLEAR INSTRUMENTS & METHODS, 1970, 83 (01): : 131 - &
  • [39] Digital pulse-shape processing for CdTe detectors
    Bargholtz, C
    Fumero, E
    Mårtensson, L
    Wachtmeister, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 471 (1-2): : 290 - 292
  • [40] Principal Component Analysis for pulse-shape discrimination of scintillation radiation detectors
    Alharbi, T.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 806 : 240 - 243