Response of AGATA Segmented HPGe Detectors to Gamma-Rays up to 15.1 MeV

被引:0
|
作者
Crespi, F. C. L. [1 ]
Avigo, R. [1 ]
Camera, F. [1 ]
Benzoni, G. [2 ]
Blasi, N. [2 ]
Bottoni, S. [1 ]
Bracco, A. [1 ]
Brambilla, S.
Casati, P. [1 ]
Coniglio, F. [1 ]
Corsi, A. [1 ,10 ]
Giaz, A. [1 ]
Leoni, S. [1 ]
Million, B. [2 ]
Nicolini, R. [1 ]
Pellegri, L. [1 ]
Riboldi, S. [1 ]
Vandone, V. [1 ]
Wieland, O. [2 ]
Akkoyun, S. [3 ]
Atac, A. [3 ]
Bazzacco, D. [4 ]
Bellato, M. [4 ]
Bortolato, D. [4 ]
Calore, E. [5 ]
Ciemala, M.
Farnea, E. [4 ]
Gadea, A. [7 ]
Gottardo, A. [8 ]
Kmiecik, M. [6 ]
Maj, A. [6 ]
Mengoni, D. [8 ]
Michelagnoli, C. [8 ]
Montanari, D. [8 ]
Napoli, D. R. [5 ]
Nyberg, J. [9 ]
Recchia, F. [5 ]
Sahin, E. [5 ]
Soderstrom, P. -A. [9 ]
Ur, C. [5 ]
Dobon, J. J. Valiente [5 ]
机构
[1] Univ Milan, Via Celoria 16, I-20133 Milan, Italy
[2] INFN sez Milano, I-20133 Milan, Italy
[3] Ankara Univ, Fac Sci, Dept Phys, TR-06100 Ankara, Turkey
[4] INFN Padova, Padua, Italy
[5] INFN, Lab Nazl Legnaro, Legnaro, Italy
[6] Polish Acad Sci, Niewodniczanski Inst Nucl Phys, Krakow, Poland
[7] Univ Valencia, CSIC, IFIC, Valencia, Spain
[8] Univ Padua, INFN, Padua, Italy
[9] Uppsala Univ, Dept Phys & Astron, Uppsala, Sweden
[10] CEA Saclay, F-91191 Gif Sur Yvette, France
关键词
PULSE-SHAPE ANALYSIS; TRACKING ARRAY; DIPOLE; STATES;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In many in-beam gamma spectroscopy experiments the detection of high-energy gamma rays in the range up to 10-20 MeV is of primary importance. New generation high-resolution gamma-ray spectrometers like AGATA and GRETA are composed of position sensitive segmented HPGe detectors and provide a reconstruction of the gamma-ray tracks. The performance of AGATA detectors in this energy range has, however, never been studied in detail. A measurement of the response to 15.1 MeV gamma rays has been performed using two HPGe triple clusters of the AGATA Demonstrator array, operating at LNL-INFN. This manuscript presents the preliminary results of a test of the AGATA detectors for the measurement of high-energy gamma rays, in terms of detection efficiency, energy resolution, tracking and performance of the pulse shape analysis (PSA) algorithms.
引用
收藏
页码:1147 / 1149
页数:3
相关论文
共 50 条
  • [1] Response of AGATA segmented HPGe detectors to gamma rays up to 15.1 MeV
    Crespi, F. C. L.
    Avigo, R.
    Camera, F.
    Akkoyun, S.
    Atac, A.
    Bazzacco, D.
    Bellato, M.
    Benzoni, G.
    Blasi, N.
    Bortolato, D.
    Bottoni, S.
    Bracco, A.
    Brambilla, S.
    Bruyneel, B.
    Ceruti, S.
    Ciemala, M.
    Coelli, S.
    Eberth, J.
    Fanin, C.
    Farnea, E.
    Gadea, A.
    Giaz, A.
    Gottardo, A.
    Hess, H.
    Kmiecik, M.
    Leoni, S.
    Maj, A.
    Mengoni, D.
    Michelagnoli, C.
    Million, B.
    Montanari, D.
    Nicolini, R.
    Pellegri, L.
    Recchia, F.
    Reiter, P.
    Riboldi, S.
    Ur, C. A.
    Vandone, V.
    Valiente-Dobon, J. J.
    Wieland, O.
    Wiens, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 705 : 47 - 54
  • [2] DETECTION EFFICIENCY OF GE(LI) AND HPGE DETECTORS FOR GAMMA-RAYS UP TO 10 MEV
    LIN, J
    HENRY, EA
    MEYER, RA
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1981, 28 (02) : 1548 - 1550
  • [3] Tracking γ rays in highly segmented HPGe detectors: A review of AGATA and GRETINA
    Korichi, A.
    Lauritsen, T.
    EUROPEAN PHYSICAL JOURNAL A, 2019, 55 (07):
  • [4] DETECTING HIGH-ENERGY GAMMA-RAYS WITH HPGE DETECTORS
    CAMERA, F
    BRACCO, A
    BOSETTI, P
    MATTIUZZI, M
    LOBIANCO, G
    PIGNANELLI, M
    GAARDHOLE, JJ
    ZELAZNY, Z
    BEARDEN, IG
    MAJ, A
    ACTA PHYSICA POLONICA B, 1995, 26 (2-3): : 479 - 485
  • [5] SIMSPEC-G: a simple code for the simulation of HPGe detectors for gamma rays up to 1 MeV
    Nayak, S. S.
    Mukherjee, G.
    JOURNAL OF INSTRUMENTATION, 2022, 17 (07)
  • [6] Angular response of a HPGe detector to gamma-rays in in situ measurements
    Nir-El, Y
    Sima, O
    APPLIED RADIATION AND ISOTOPES, 2001, 55 (01) : 1 - 7
  • [7] DETECTION EFFICIENCY OF GE-DETECTORS AND GE(LI) DETECTORS FOR GAMMA-RAYS UP TO 10-MEV
    LIN, J
    HENRY, EA
    MEYER, RA
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1980, 25 (07): : 784 - 784
  • [9] Pulse-Shape Analysis and position resolution in highly segmented HPGe AGATA detectors
    Lewandowski, L.
    Reiter, P.
    Birkenbach, B.
    Bruyneel, B.
    Clemente, E.
    Eberth, J.
    Hess, H.
    Michelagnoli, C.
    Li, H.
    Perez-Vidal, R. M.
    Zielinska, M.
    EUROPEAN PHYSICAL JOURNAL A, 2019, 55 (05):
  • [10] Pulse-Shape Analysis and position resolution in highly segmented HPGe AGATA detectors
    L. Lewandowski
    P. Reiter
    B. Birkenbach
    B. Bruyneel
    E. Clement
    J. Eberth
    H. Hess
    C. Michelagnoli
    H. Li
    R. M. Perez-Vidal
    M. Zielinska
    The European Physical Journal A, 2019, 55