Response of AGATA Segmented HPGe Detectors to Gamma-Rays up to 15.1 MeV

被引:0
|
作者
Crespi, F. C. L. [1 ]
Avigo, R. [1 ]
Camera, F. [1 ]
Benzoni, G. [2 ]
Blasi, N. [2 ]
Bottoni, S. [1 ]
Bracco, A. [1 ]
Brambilla, S.
Casati, P. [1 ]
Coniglio, F. [1 ]
Corsi, A. [1 ,10 ]
Giaz, A. [1 ]
Leoni, S. [1 ]
Million, B. [2 ]
Nicolini, R. [1 ]
Pellegri, L. [1 ]
Riboldi, S. [1 ]
Vandone, V. [1 ]
Wieland, O. [2 ]
Akkoyun, S. [3 ]
Atac, A. [3 ]
Bazzacco, D. [4 ]
Bellato, M. [4 ]
Bortolato, D. [4 ]
Calore, E. [5 ]
Ciemala, M.
Farnea, E. [4 ]
Gadea, A. [7 ]
Gottardo, A. [8 ]
Kmiecik, M. [6 ]
Maj, A. [6 ]
Mengoni, D. [8 ]
Michelagnoli, C. [8 ]
Montanari, D. [8 ]
Napoli, D. R. [5 ]
Nyberg, J. [9 ]
Recchia, F. [5 ]
Sahin, E. [5 ]
Soderstrom, P. -A. [9 ]
Ur, C. [5 ]
Dobon, J. J. Valiente [5 ]
机构
[1] Univ Milan, Via Celoria 16, I-20133 Milan, Italy
[2] INFN sez Milano, I-20133 Milan, Italy
[3] Ankara Univ, Fac Sci, Dept Phys, TR-06100 Ankara, Turkey
[4] INFN Padova, Padua, Italy
[5] INFN, Lab Nazl Legnaro, Legnaro, Italy
[6] Polish Acad Sci, Niewodniczanski Inst Nucl Phys, Krakow, Poland
[7] Univ Valencia, CSIC, IFIC, Valencia, Spain
[8] Univ Padua, INFN, Padua, Italy
[9] Uppsala Univ, Dept Phys & Astron, Uppsala, Sweden
[10] CEA Saclay, F-91191 Gif Sur Yvette, France
关键词
PULSE-SHAPE ANALYSIS; TRACKING ARRAY; DIPOLE; STATES;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In many in-beam gamma spectroscopy experiments the detection of high-energy gamma rays in the range up to 10-20 MeV is of primary importance. New generation high-resolution gamma-ray spectrometers like AGATA and GRETA are composed of position sensitive segmented HPGe detectors and provide a reconstruction of the gamma-ray tracks. The performance of AGATA detectors in this energy range has, however, never been studied in detail. A measurement of the response to 15.1 MeV gamma rays has been performed using two HPGe triple clusters of the AGATA Demonstrator array, operating at LNL-INFN. This manuscript presents the preliminary results of a test of the AGATA detectors for the measurement of high-energy gamma rays, in terms of detection efficiency, energy resolution, tracking and performance of the pulse shape analysis (PSA) algorithms.
引用
收藏
页码:1147 / 1149
页数:3
相关论文
共 50 条
  • [11] Pulse shape analysis and position determination in segmented HPGe detectors: The AGATA detector library
    Bruyneel, B.
    Birkenbach, B.
    Reiter, P.
    EUROPEAN PHYSICAL JOURNAL A, 2016, 52 (03):
  • [12] Gamma-ray tracking with segmented HPGe detectors
    Wieland, O
    Kröll, T
    Bazzacco, D
    Venturelli, R
    Camera, F
    Million, B
    Musso, E
    Quintana, B
    Ur, CA
    Bellato, M
    Isocrate, R
    Manea, C
    Menegazzo, R
    Pavan, P
    Alvarez, CR
    Farnea, E
    Gadea, A
    Rosso, D
    Spolaore, R
    Pullia, A
    Casati, G
    Geraci, A
    Ripamonti, G
    Descovich, M
    BRAZILIAN JOURNAL OF PHYSICS, 2003, 33 (02) : 206 - 210
  • [13] Pulse shape analysis and position determination in segmented HPGe detectors: The AGATA detector library
    B. Bruyneel
    B. Birkenbach
    P. Reiter
    The European Physical Journal A, 2016, 52
  • [14] THE RESPONSE OF A HPGE DETECTOR WITH A BGO SHIELD TO HIGH-ENERGY GAMMA-RAYS
    CAMERA, F
    BRACCO, A
    MATTIUZZI, M
    LOBIANCO, G
    PIGNANELLI, M
    GAARDHOJE, JJ
    BEARDEN, IG
    ZELAZNY, Z
    MAJ, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 351 (2-3): : 401 - 405
  • [15] RESPONSE OF NAL DETECTORS TO HIGH-ENERGY GAMMA-RAYS
    SELTZER, SM
    BERGER, MJ
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1971, 14 (01): : 124 - &
  • [16] METHOD FOR SYNTHESIZING RESPONSE FUNCTIONS OF NAI DETECTORS TO GAMMA-RAYS
    SIE, SH
    NUCLEAR INSTRUMENTS & METHODS, 1978, 155 (03): : 475 - 483
  • [17] SENSITIVITY OF EMISSION DETECTORS TO GAMMA-RAYS
    KULAKOV, GV
    MUKHACHEV, BV
    SOVIET ATOMIC ENERGY, 1976, 40 (06): : 576 - 578
  • [18] Modeling an HPGe detector response to gamma-rays using MCNP5 code
    Prozorova, I. V.
    Sabitova, R. R.
    Ghal-Eh, N.
    Bedenko, S. V.
    INTERNATIONAL JOURNAL OF MODERN PHYSICS C, 2019, 30 (11):
  • [19] DETECTION EFFICIENCY OF SI(LI) DETECTORS FOR 0.05-1.25-MEV GAMMA-RAYS
    KOZHEMYAKIN, VA
    SHULGOVICH, GI
    SOVIET ATOMIC ENERGY, 1977, 42 (04): : 342 - 344
  • [20] CdTe detectors' response to irradiation with high-energy gamma-rays
    Chirco, P
    Caroli, E
    Cavallini, A
    Dusi, W
    Fraboni, B
    Hage-Ali, M
    Morigi, MP
    Siffert, P
    Zanarini, M
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2000, 47 (06) : 2078 - 2083