Response of AGATA Segmented HPGe Detectors to Gamma-Rays up to 15.1 MeV

被引:0
|
作者
Crespi, F. C. L. [1 ]
Avigo, R. [1 ]
Camera, F. [1 ]
Benzoni, G. [2 ]
Blasi, N. [2 ]
Bottoni, S. [1 ]
Bracco, A. [1 ]
Brambilla, S.
Casati, P. [1 ]
Coniglio, F. [1 ]
Corsi, A. [1 ,10 ]
Giaz, A. [1 ]
Leoni, S. [1 ]
Million, B. [2 ]
Nicolini, R. [1 ]
Pellegri, L. [1 ]
Riboldi, S. [1 ]
Vandone, V. [1 ]
Wieland, O. [2 ]
Akkoyun, S. [3 ]
Atac, A. [3 ]
Bazzacco, D. [4 ]
Bellato, M. [4 ]
Bortolato, D. [4 ]
Calore, E. [5 ]
Ciemala, M.
Farnea, E. [4 ]
Gadea, A. [7 ]
Gottardo, A. [8 ]
Kmiecik, M. [6 ]
Maj, A. [6 ]
Mengoni, D. [8 ]
Michelagnoli, C. [8 ]
Montanari, D. [8 ]
Napoli, D. R. [5 ]
Nyberg, J. [9 ]
Recchia, F. [5 ]
Sahin, E. [5 ]
Soderstrom, P. -A. [9 ]
Ur, C. [5 ]
Dobon, J. J. Valiente [5 ]
机构
[1] Univ Milan, Via Celoria 16, I-20133 Milan, Italy
[2] INFN sez Milano, I-20133 Milan, Italy
[3] Ankara Univ, Fac Sci, Dept Phys, TR-06100 Ankara, Turkey
[4] INFN Padova, Padua, Italy
[5] INFN, Lab Nazl Legnaro, Legnaro, Italy
[6] Polish Acad Sci, Niewodniczanski Inst Nucl Phys, Krakow, Poland
[7] Univ Valencia, CSIC, IFIC, Valencia, Spain
[8] Univ Padua, INFN, Padua, Italy
[9] Uppsala Univ, Dept Phys & Astron, Uppsala, Sweden
[10] CEA Saclay, F-91191 Gif Sur Yvette, France
关键词
PULSE-SHAPE ANALYSIS; TRACKING ARRAY; DIPOLE; STATES;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In many in-beam gamma spectroscopy experiments the detection of high-energy gamma rays in the range up to 10-20 MeV is of primary importance. New generation high-resolution gamma-ray spectrometers like AGATA and GRETA are composed of position sensitive segmented HPGe detectors and provide a reconstruction of the gamma-ray tracks. The performance of AGATA detectors in this energy range has, however, never been studied in detail. A measurement of the response to 15.1 MeV gamma rays has been performed using two HPGe triple clusters of the AGATA Demonstrator array, operating at LNL-INFN. This manuscript presents the preliminary results of a test of the AGATA detectors for the measurement of high-energy gamma rays, in terms of detection efficiency, energy resolution, tracking and performance of the pulse shape analysis (PSA) algorithms.
引用
收藏
页码:1147 / 1149
页数:3
相关论文
共 50 条
  • [41] NUCLEAR SCATTERING OF 17-MEV GAMMA-RAYS
    STEARNS, MB
    PHYSICAL REVIEW, 1952, 87 (05): : 706 - 715
  • [42] SOLAR GAMMA-RAYS ABOVE 8-MEV
    CRANNELL, CJ
    CRANNELL, H
    RAMATY, R
    ASTROPHYSICAL JOURNAL, 1979, 229 (02): : 762 - 771
  • [43] ENERGY CALIBRATION OF GAMMA-RAYS ABOVE 1 MEV
    NAWROCKI, EA
    MULTHAUF, LG
    TIRSELL, KG
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1973, 18 (04): : 720 - 720
  • [44] Evaluation the nonlinear response function of a HPGe detector for 59 keV to 10.7 MeV gamma-rays using a Monte Carlo simulation and comparison with experimental data
    Saheli, F.
    Riazi, Z.
    Jokar, A.
    Shahabinejad, H.
    Vosoughi, N.
    Ghasemi, S. A.
    JOURNAL OF INSTRUMENTATION, 2021, 16 (07)
  • [45] NEUTRON-INDUCED GAMMA-RAYS IN GERMANIUM DETECTORS
    CHAO, JH
    APPLIED RADIATION AND ISOTOPES, 1993, 44 (03) : 605 - 611
  • [46] LEC SI-GAAS DETECTORS FOR GAMMA-RAYS
    DOGRU, M
    BEAUMONT, SP
    BERTIN, R
    BOOTH, CN
    BUTTAR, C
    CAPILUPPI, C
    CARRARESI, L
    CINDOLO, F
    COLOCCI, M
    COMBLEY, FH
    DAURIA, S
    DELPAPA, C
    EDWARDS, M
    FIORI, F
    FOSTER, F
    FRANCESCATO, A
    GRAY, R
    HILL, G
    HOU, Y
    HOUSTON, P
    HUGHES, G
    JONES, BK
    LYNCH, JG
    LISOWSKY, B
    MATHESON, J
    NAVA, F
    NUTI, M
    OSHEA, V
    PELFER, PG
    RAINE, C
    RATOFF, P
    SANTANA, J
    SAUNDERS, IJ
    SELLER, PH
    SHANKAR, K
    SHARP, PH
    SKILLICORN, IO
    SLOAN, T
    SMITH, KM
    TARTONI, I
    TENHAVE, I
    TURNBULL, RM
    VANNI, U
    VINATTIERI, A
    ZICHICHI, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 348 (2-3): : 510 - 513
  • [47] ENERGY CALIBRATION OF ORGANIC SCINTILLATION DETECTORS FOR GAMMA-RAYS
    DIEHL, R
    GRASER, U
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1981, 186 (03): : 665 - 668
  • [48] ENERGY CALIBRATION OF ORGANIC SCINTILLATION DETECTORS FOR GAMMA-RAYS
    GU, JH
    XIAO, GL
    LIU, JG
    SHI, SH
    LI, Y
    TIAN, JQ
    CHINESE PHYSICS, 1988, 8 (04): : 1030 - 1034
  • [49] Simulations using the pulse shape comparison scanning technique on an AGATA segmented HPGe gamma-ray detector
    De Canditiis B.
    Duchêne G.
    European Physical Journal A, 2020, 56 (10):
  • [50] RESPONSE OF SCINTILLATING AND CHERENKOV RADIATING GLASSES TO GAMMA-RAYS OF ENERGY BELOW 100 MEV
    BIINO, C
    CESTER, R
    MENICHETTI, E
    PALESTINI, S
    PESANDO, L
    PICCOTTI, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1987, 262 (2-3): : 408 - 412