Quantification of Colistin in Plasma by Liquid Chromatography-Tandem Mass Spectrometry: Application to a Pharmacokinetic Study

被引:0
|
作者
Kamal M. Matar
Batool Al-Refai
机构
[1] Faculty of Pharmacy,Department of Pharmacology & Therapeutics
[2] Kuwait University,undefined
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Colistin is a polymixin antibiotic (polymixin E) that is produced by Bacillus colistinus bacteria. The aim of the present study was to develop and validate a method to quantify colistin levels in plasma using high performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) technique and then apply it in experimental animals (rats) to investigate the pharmacokinetic profile of colistin in this species. Polymyxin B was used as an internal standard (IS) and the quantitation was carried out using ESI + interface and employing multiple reaction monitoring (MRM) mode. A mobile phase consisting of acetonitrile:water:formic acid (30:70:0.1%; v/v/v) was employed and Zorbax eclipse plus C18 (1.8 µm, 2.1 mm i.d. x 50 mm) was the optimal column for this method and utilized at a flow rate of 0.2 mL/min. The full scan mass spectra of precursor/product ions of colistin A were at m/z 585.5 > 100.8, for colistin B at m/z 578.8 > 101 and for the IS at m/z 602.8 > 101. The lower limit of quantification (LLOQ) was 0.5 µg/mL. The method demonstrated acceptable intra-run and inter-run precision and accuracy for both colistin A and colistin B. Colistin was stable when assessed for long-term stability, freeze-thaw stability and autosampler stability. However, it was not stable when stored at room temperature. The matrix effect evaluation showed minimal or no effect. Incurred sample reanalysis findings were within acceptable ranges (<20% of the nominal concentration). The pharmacokinetic parameters of colistin were investigated in rats using the present method. The developed method for colistin demonstrates that it is rapid, sensitive, specific, accurate, precise, and reliable.
引用
收藏
相关论文
共 50 条
  • [1] Quantification of Colistin in Plasma by Liquid Chromatography-Tandem Mass Spectrometry: Application to a Pharmacokinetic Study
    Matar, Kamal M.
    Al-Refai, Batool
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [2] Liquid chromatography-tandem mass/mass spectrometry method for the quantification of rabeprazole in human plasma and application to a pharmacokinetic study
    Yu, Liyan
    Deng, Haishan
    Xiang, Bingren
    ARZNEIMITTELFORSCHUNG-DRUG RESEARCH, 2010, 60 (05): : 262 - 266
  • [3] Quantification of oltipraz using liquid chromatography-tandem mass spectrometry and its application to a pharmacokinetic study in rat plasma
    Lee, Jong-Hwa
    Lim, Hwanmi
    Kim, Do-Geun
    Park, Dae-Hun
    Woo, Young-Ah
    Noh, Hyun-Jung
    Jin, Qing-Ri
    Lee, Kyeong-Ryoon
    Lee, Gye-Won
    Kim, Choong-Yong
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2011, 56 (03) : 623 - 626
  • [4] Rapid quantification of astilbin in rat plasma by liquid chromatography-tandem mass spectrometry and its application to pharmacokinetic study
    Yin Lei
    Zhang Yun-hui
    Zhao Sen
    Cheng Long-mei
    Shi Mei-yun
    Yang Yan
    Sun Yan-tong
    Liu Xi-dong
    Fawcett, J. Paul
    CHEMICAL RESEARCH IN CHINESE UNIVERSITIES, 2013, 29 (06) : 1078 - 1082
  • [5] Rapid quantification of astilbin in rat plasma by liquid chromatography-tandem mass spectrometry and its application to pharmacokinetic study
    Lei Yin
    Yun-hui Zhang
    Sen Zhao
    Long-mei Cheng
    Mei-yun Shi
    Yan Yang
    Yan-tong Sun
    Xi-dong Liu
    J. Paul Fawcett
    Chemical Research in Chinese Universities, 2013, 29 : 1078 - 1082
  • [6] Liquid chromatography-tandem mass spectrometry for quantification of cefaclor in rat plasma and its application to pharmacokinetic studies
    Jin H.-E.
    Kim Y.C.
    Maeng H.-J.
    Journal of Pharmaceutical Investigation, 2014, 44 (2) : 133 - 139
  • [7] Liquid chromatography-tandem mass spectrometry for quantification of lacosamide, an antiepileptic drug, in rat plasma and its application to pharmacokinetic study
    Kim, Soo-Jin
    Koo, Tae-Sung
    Ha, Dong-Jin
    Baek, Myoungki
    Lee, Sang-Kil
    Shin, Dong-Soo
    Moon, Hongsik
    BIOMEDICAL CHROMATOGRAPHY, 2012, 26 (03) : 371 - 376
  • [8] Quantification of pinosylvin in rat plasma by liquid chromatography-tandem mass spectrometry: Application to a pre-clinical pharmacokinetic study
    Yeo, Samuel Chao Ming
    Luo, Wenxia
    Wu, Jinzhu
    Ho, Paul C.
    Lin, Hai-Shu
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2013, 931 : 68 - 74
  • [9] Quantification of belatacept by liquid chromatography-tandem mass spectrometry in human plasma: Application to a pharmacokinetic study in renal transplant recipients
    Truffot, Aurelie
    Jourdil, Jean-Francois
    Veyret-Gautier, Elodie
    Noble, Johan
    Jouve, Thomas
    Malvezzi, Paolo
    Rostaing, Lionel
    Stanke-Labesque, Francoise
    CLINICAL BIOCHEMISTRY, 2023, 113 : 17 - 20
  • [10] A simple and accurate liquid chromatography-tandem mass spectrometry method for quantification of zonisamide in plasma and its application to a pharmacokinetic study
    Matar, Kamal M.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 961 : 103 - 109