Liquid chromatography-tandem mass spectrometry for quantification of cefaclor in rat plasma and its application to pharmacokinetic studies

被引:1
|
作者
Jin H.-E. [1 ]
Kim Y.C. [2 ]
Maeng H.-J. [3 ]
机构
[1] College of Pharmacy, Seoul National University, Seoul, 151-742, 599 Gwanak-ro, Gwanak-gu
[2] CandC Research Laboratories, Suwon, Gyeonggi
[3] College of Pharmacy, Inje University, Gimhae, Gyeongnam
关键词
Cefaclor; Liquid chromatography-tandem mass spectrometry (LC-MS/MS); Pharmacokinetics; Plasma; Rat;
D O I
10.1007/s40005-013-0109-9
中图分类号
学科分类号
摘要
A simple and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) in the positive electrospray ionization mode was developed and validated in order to analyze cefaclor, a second generation cephalosporin antibiotic, in rat plasma. The plasma was pre-treated by a single step of protein precipitation with methanol, and then injected directly into the LC/MS/MS system for quantification. Drugs were separated on a Synergi 4μ Polar-RP 80 A column (150 × 2.0 mm) with a mixture of 0.1 % formic acid and methanol (65: 35, v/v) as the mobile phase at 0.2 mL/min. Detection was performed with multiple reaction-monitoring modes at m/z 368.1 → 174.2 (for cefaclor) and m/z 396.0 → 227.1 (for cefdinir, the internal standard). The limit of quantification (LOQ) was determined to be 10 ng/mL with acceptable linearity ranging from 10 to 10,000 ng/mL. Validation parameters for cefaclor, including accuracy, precision, absolute matrix effect, and stability in rat plasma, were acceptable according to the assay validation guidelines of the FDA (U.S. Department of Health & Human Services, Food and Drug Administration, Guidance for Industry, Bioanalytical Method Validation, 2001). The developed analytical method was successfully applied to the pharmacokinetic studies of cefaclor in rats. These observations suggest, therefore, that the validated assay can be used in routine pharmacokinetic studies of cefaclor in rats. © 2013 The Korean Society of Pharmaceutical Sciences and Technology.
引用
收藏
页码:133 / 139
页数:6
相关论文
共 50 条
  • [1] Quantification of oltipraz using liquid chromatography-tandem mass spectrometry and its application to a pharmacokinetic study in rat plasma
    Lee, Jong-Hwa
    Lim, Hwanmi
    Kim, Do-Geun
    Park, Dae-Hun
    Woo, Young-Ah
    Noh, Hyun-Jung
    Jin, Qing-Ri
    Lee, Kyeong-Ryoon
    Lee, Gye-Won
    Kim, Choong-Yong
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2011, 56 (03) : 623 - 626
  • [2] Rapid quantification of astilbin in rat plasma by liquid chromatography-tandem mass spectrometry and its application to pharmacokinetic study
    Yin Lei
    Zhang Yun-hui
    Zhao Sen
    Cheng Long-mei
    Shi Mei-yun
    Yang Yan
    Sun Yan-tong
    Liu Xi-dong
    Fawcett, J. Paul
    [J]. CHEMICAL RESEARCH IN CHINESE UNIVERSITIES, 2013, 29 (06) : 1078 - 1082
  • [3] Rapid quantification of astilbin in rat plasma by liquid chromatography-tandem mass spectrometry and its application to pharmacokinetic study
    Lei Yin
    Yun-hui Zhang
    Sen Zhao
    Long-mei Cheng
    Mei-yun Shi
    Yan Yang
    Yan-tong Sun
    Xi-dong Liu
    J. Paul Fawcett
    [J]. Chemical Research in Chinese Universities, 2013, 29 : 1078 - 1082
  • [4] Liquid chromatography-tandem mass spectrometry for quantification of lacosamide, an antiepileptic drug, in rat plasma and its application to pharmacokinetic study
    Kim, Soo-Jin
    Koo, Tae-Sung
    Ha, Dong-Jin
    Baek, Myoungki
    Lee, Sang-Kil
    Shin, Dong-Soo
    Moon, Hongsik
    [J]. BIOMEDICAL CHROMATOGRAPHY, 2012, 26 (03) : 371 - 376
  • [5] Quantification of Colistin in Plasma by Liquid Chromatography-Tandem Mass Spectrometry: Application to a Pharmacokinetic Study
    Kamal M. Matar
    Batool Al-Refai
    [J]. Scientific Reports, 10
  • [6] Quantification of Colistin in Plasma by Liquid Chromatography-Tandem Mass Spectrometry: Application to a Pharmacokinetic Study
    Matar, Kamal M.
    Al-Refai, Batool
    [J]. SCIENTIFIC REPORTS, 2020, 10 (01)
  • [7] A liquid chromatography-tandem mass spectrometry method development for the quantification of favipiravir drug and its related impurities in rat plasma and its application to pharmacokinetic studies
    Koganti, Kalyani
    Babu, Namburi L. A. Amara
    Sattu, Naga Raju
    Rao, Koya Prabhakara
    [J]. BIOMEDICAL CHROMATOGRAPHY, 2024, 38 (04)
  • [8] Quantification of thonningianin a in rat plasma by liquid chromatography tandem mass spectrometry and its application to a pharmacokinetic study
    Liu, Qian
    Li, Chunmin
    Zhao, Pan
    Li, Jing
    Deng, Zhipeng
    [J]. PHARMACEUTICAL BIOLOGY, 2021, 59 (01) : 525 - 531
  • [9] Rapid and efficient method for the quantification of lychnopholide in rat plasma by liquid chromatography-tandem mass spectrometry for pharmacokinetic application
    Lachi-Silva, Larissa
    Barreto Sousa, Joao Paulo
    Montanha, Maiara Camotti
    Sy, Sherwin K. B.
    Callegari Lopes, Joao Luis
    Silva, Denise Brentan
    Lopes, Norberto Peporine
    Diniz, Andrea
    Kimura, Elza
    [J]. BIOMEDICAL CHROMATOGRAPHY, 2016, 30 (07) : 1092 - 1096
  • [10] Determination of chrysotoxine in rat plasma by liquid chromatography-tandem mass spectrometry and its application to a rat pharmacokinetic study
    Fan, Jingjing
    Guan, Li
    Kou, Zeqi
    Feng, Feng
    Zhang, Yanbo
    Liu, Wenyuan
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 967 : 57 - 62