Quantification of Colistin in Plasma by Liquid Chromatography-Tandem Mass Spectrometry: Application to a Pharmacokinetic Study

被引:0
|
作者
Kamal M. Matar
Batool Al-Refai
机构
[1] Faculty of Pharmacy,Department of Pharmacology & Therapeutics
[2] Kuwait University,undefined
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Colistin is a polymixin antibiotic (polymixin E) that is produced by Bacillus colistinus bacteria. The aim of the present study was to develop and validate a method to quantify colistin levels in plasma using high performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) technique and then apply it in experimental animals (rats) to investigate the pharmacokinetic profile of colistin in this species. Polymyxin B was used as an internal standard (IS) and the quantitation was carried out using ESI + interface and employing multiple reaction monitoring (MRM) mode. A mobile phase consisting of acetonitrile:water:formic acid (30:70:0.1%; v/v/v) was employed and Zorbax eclipse plus C18 (1.8 µm, 2.1 mm i.d. x 50 mm) was the optimal column for this method and utilized at a flow rate of 0.2 mL/min. The full scan mass spectra of precursor/product ions of colistin A were at m/z 585.5 > 100.8, for colistin B at m/z 578.8 > 101 and for the IS at m/z 602.8 > 101. The lower limit of quantification (LLOQ) was 0.5 µg/mL. The method demonstrated acceptable intra-run and inter-run precision and accuracy for both colistin A and colistin B. Colistin was stable when assessed for long-term stability, freeze-thaw stability and autosampler stability. However, it was not stable when stored at room temperature. The matrix effect evaluation showed minimal or no effect. Incurred sample reanalysis findings were within acceptable ranges (<20% of the nominal concentration). The pharmacokinetic parameters of colistin were investigated in rats using the present method. The developed method for colistin demonstrates that it is rapid, sensitive, specific, accurate, precise, and reliable.
引用
收藏
相关论文
共 50 条
  • [21] Liquid chromatography-tandem mass spectrometry method for the estimation of adefovir in human plasma:Application to a pharmacokinetic study
    Dipanjan Goswami
    Sanjay Gurule
    Arabinda Saha
    Poonam Vats
    Arshad Khuroo
    Tausif Monif
    Journal of Pharmaceutical Analysis, 2015, 5 (03) : 190 - 199
  • [22] Pharmacokinetic analysis of plasma bicyclol by liquid chromatography-tandem mass spectrometry
    Liu, Mingyi
    Huang, Shibo
    Wen, Jinhua
    Xia, Chunhua
    Zhang, Hong
    Xiong, Yuqing
    BIOMEDICAL CHROMATOGRAPHY, 2019, 33 (11)
  • [23] Determination of limonin in dog plasma by liquid chromatography-tandem mass spectrometry and its application to a pharmacokinetic study
    Liu, Shi-jia
    Zhou, Ling
    Zhang, Jun
    Yu, Bo-yang
    Li, Chang-yin
    Liu, Zi-xiu
    Ju, Wen-zheng
    BIOMEDICAL CHROMATOGRAPHY, 2013, 27 (04) : 515 - 519
  • [24] Liquid chromatography-tandem mass spectrometry determination of bumetanide in human plasma and application to a clinical pharmacokinetic study
    Tamilarasi, Ganesan Padmini
    Manikandan, Krishnan
    Solomon, Viswas Raja
    BIOMEDICAL CHROMATOGRAPHY, 2024, 38 (04)
  • [25] Determination of mitoxantrone in rat plasma by liquid chromatography-tandem mass spectrometry method: Application to a pharmacokinetic study
    Zhang, Peng
    Ling, Guixia
    Sun, Jin
    Sun, Yongbing
    Pu, Xiaohui
    Wang, Zhiyuan
    He, Zhonggui
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (24): : 2260 - 2265
  • [26] Determination of zolmitriptan in human plasma by liquid chromatography-tandem mass spectrometry method: Application to a pharmacokinetic study
    Chen, XY
    Liu, D
    Luan, Y
    Jin, FD
    Zhong, DF
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 832 (01): : 30 - 35
  • [27] Rapid Determination of Imatinib in Human Plasma by Liquid Chromatography-Tandem Mass Spectrometry: Application to a Pharmacokinetic Study
    Yang, Jeong Soo
    Cho, Eun Gi
    Huh, Wooseong
    Ko, Jae-Wook
    Jung, Jin Ah
    Lee, Soo-Youn
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2013, 34 (08) : 2425 - 2430
  • [28] Determination of sitafloxacin in human plasma by liquid chromatography-tandem mass spectrometry method: Application to a pharmacokinetic study
    Huang, Kai
    Yang, Jie
    Zhang, Jing
    Ding, Ying
    Chen, Lan
    Xu, Wen-Yan
    Xu, Xue-Jiao
    Duan, Ru
    He, Qing
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 957 : 36 - 40
  • [29] Liquid Chromatography — Tandem Mass Spectrometry Method for Quantification of Zolpidem in Human Plasma: Application to Pharmacokinetic Study
    S. Dodda
    A. Makula
    S. R. Polagani
    R. N. Kandhagatla
    Journal of Applied Spectroscopy, 2020, 87 : 951 - 957
  • [30] Liquid chromatography/tandem mass spectrometry method for the quantification of deserpidine in human plasma: Application to a pharmacokinetic study
    Zhang, Huaicheng
    Zhong, Dafang
    Zhang, Zhenzhong
    Dai, Xiaojian
    Chen, Xiaoyan
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (27): : 3221 - 3225