Influence of surface stress on frequency of microcantilever-based biosensors

被引:0
|
作者
Q. Ren
Y.-P. Zhao
机构
[1] Institute of Mechanics,State Key Laboratory of Nonlinear Mechanics (LNM)
来源
Microsystem Technologies | 2004年 / 10卷
关键词
Resonance Frequency; Governing Equation; Unique Characteristic; Iteration Method; Surface Stress;
D O I
暂无
中图分类号
学科分类号
摘要
Microcantilever-based biosensors have been found increasing applications in physical, chemical, and biological fields in recent years. When biosensors are used in those fields, surface stress and mass variations due to bio-molecular binding can cause the microcantilever deform or the shift of frequency. These simple biosensors allow biologists to study surface biochemistry on a micro or nano scale and offer new opportunities in developing microscopic biomedical analysis with unique characteristics. To compare and illustrate the influence of the surface stress on the frequency and avoid unnecessary and complicated numerical solution of the resonance frequency, some dimensionless numbers are derived in this paper by making governing equations dimensionless. Meanwhile, in order to analyze the influence of the general surface stress on the frequency, a new model is put forward, and the frequency of the microcantilever is calculated by using the subspace iteration method and the Rayleigh method. The sensitivity of microcantilever is also discussed.
引用
收藏
页码:307 / 314
页数:7
相关论文
共 50 条
  • [1] Influence of surface stress on frequency of microcantilever-based biosensors
    Ren, Q
    Zhao, YP
    [J]. MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2004, 10 (04): : 307 - 314
  • [2] Influence of surface stress on frequency of microcantilever-based biosensors
    Q. Ren
    Y.-P. Zhao
    [J]. Microsystem Technologies, 2005, 11 : 456 - 456
  • [3] Influence of surface stress on frequency of microcantilever-based biosensors (vol 10, pg 307, 2004)
    Ren, Q
    Zhao, YP
    [J]. MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2005, 11 (06): : 456 - 456
  • [4] Microcantilever-based biosensors
    Moulin, AM
    O'Shea, SJ
    Welland, ME
    [J]. ULTRAMICROSCOPY, 2000, 82 (1-4) : 23 - 31
  • [5] The effect of flow velocity on microcantilever-based biosensors
    Wu, M. -C.
    Chang, J. -S.
    Wu, K. -C.
    Lin, C. -H.
    Wu, C. -Y.
    [J]. JOURNAL OF MECHANICS, 2007, 23 (04) : 353 - 358
  • [6] Microcantilever-based sensors:: Effect of morphology, adhesion, and cleanliness of the sensing surface on surface stress
    Tabard-Cossa, Vincent
    Godin, Michel
    Burgess, Ian J.
    Monga, Tanya
    Lennox, R. Bruce
    Gruetter, Peter
    [J]. ANALYTICAL CHEMISTRY, 2007, 79 (21) : 8136 - 8143
  • [7] Microcantilever-based Sensors
    Chaudhary, Monika
    Gupta, Amita
    [J]. DEFENCE SCIENCE JOURNAL, 2009, 59 (06) : 634 - 641
  • [8] A differential microcantilever-based system for measuring surface stress changes induced by electrochemical reactions
    Tabard-Cossa, V
    Godin, M
    Beaulieu, LY
    Grütter, P
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2005, 107 (01): : 233 - 241
  • [9] Size-dependent effects of surface stress on resonance behavior of microcantilever-based sensors
    Sohi, Ali Najafi
    Nieva, Patricia M.
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 2018, 269 : 505 - 514
  • [10] A microcantilever-based pathogen detector
    Weeks, BL
    Camarero, J
    Noy, A
    Miller, AE
    Stanker, L
    De Yoreo, JJ
    [J]. NANOTECH 2003, VOL 1, 2003, : 123 - 125