A microcantilever-based pathogen detector

被引:0
|
作者
Weeks, BL [1 ]
Camarero, J [1 ]
Noy, A [1 ]
Miller, AE [1 ]
Stanker, L [1 ]
De Yoreo, JJ [1 ]
机构
[1] Lawrence Livermore Natl Lab, Livermore, CA 94550 USA
来源
关键词
microfabrication; cantilever; biosensor; immunosensor; surface functionalization;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The ability to detect small amounts of materials, especially bacterial organisms, is important for medical diagnostics and national security issues. Engineered micromechanical systems provide one approach for constructing multifunctional, highly sensitive, real-time, immunospecific biological detectors. We present qualitative detection of specific Salmonella strains using a functionalized silicon nitride microcantilever. Detection is achieved due to a change in the surface stress on the cantilever surface in-situ upon binding of a small number of becteria. Scanning electron micrographs indicate that less than 25 adsorbed bacteria are required for detection.
引用
收藏
页码:123 / 125
页数:3
相关论文
共 50 条
  • [1] A microcantilever-based pathogen detector
    Weeks, BL
    Camarero, J
    Noy, A
    Miller, AE
    Stanker, L
    De Yoreo, JJ
    [J]. SCANNING, 2003, 25 (06) : 297 - 299
  • [2] Microcantilever-based biosensors
    Moulin, AM
    O'Shea, SJ
    Welland, ME
    [J]. ULTRAMICROSCOPY, 2000, 82 (1-4) : 23 - 31
  • [3] Microcantilever-based Sensors
    Chaudhary, Monika
    Gupta, Amita
    [J]. DEFENCE SCIENCE JOURNAL, 2009, 59 (06) : 634 - 641
  • [4] Microcantilever-based platforms as biosensing tools
    Alvarez, Mar
    Lechuga, Laura M.
    [J]. ANALYST, 2010, 135 (05) : 827 - 836
  • [5] Microcantilever-based biosensor for detection of various biomolecules
    Yoo, Kyung-Ah
    Na, Kwang-Ho
    Joung, Seung-Ryong
    Nahm, Baek-Hie
    Kang, C.J.
    Kim, Yong-Sang
    [J]. Japanese Journal of Applied Physics, Part 1: Regular Papers and Short Notes and Review Papers, 2006, 45 (1 B): : 515 - 518
  • [6] The effect of flow velocity on microcantilever-based biosensors
    Wu, M. -C.
    Chang, J. -S.
    Wu, K. -C.
    Lin, C. -H.
    Wu, C. -Y.
    [J]. JOURNAL OF MECHANICS, 2007, 23 (04) : 353 - 358
  • [7] Design and performance of a microcantilever-based hydrogen sensor
    Baselt, DR
    Fruhberger, B
    Klaassen, E
    Cemalovic, S
    Britton, CL
    Patel, SV
    Mlsna, TE
    McCorkle, D
    Warmack, B
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2003, 88 (02) : 120 - 131
  • [8] Microcantilever-based biosensor for detection of various biomolecules
    Yoo, KA
    Na, KH
    Joung, SR
    Nahm, BH
    Kang, CJ
    Kim, YS
    [J]. JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 2006, 45 (1B): : 515 - 518
  • [9] Influence of surface stress on frequency of microcantilever-based biosensors
    Ren, Q
    Zhao, YP
    [J]. MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2004, 10 (04): : 307 - 314
  • [10] Modeling and performance of uncoated microcantilever-based chemical sensors
    Tetin, Sebastein
    Caillard, Benjamin
    Menil, Francis
    Debeda, Helene
    Lucat, Claude
    Pellet, Claude
    Dufour, Isabelle
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2010, 143 (02) : 555 - 560