Load-induced deformation of the tibia and its effect on implant loosening detection

被引:0
|
作者
M. A. ter Wee
J. G. G. Dobbe
G. S. Buijs
A. J. Kievit
M. U. Schafroth
M. Maas
L. Blankevoort
G. J. Streekstra
机构
[1] Amsterdam UMC Location University of Amsterdam,Department of Biomedical Engineering and Physics
[2] Amsterdam Movement Sciences,Department of Orthopedic Surgery and Sports Medicine
[3] Musculoskeletal Health,Department of Radiology
[4] Amsterdam UMC Location University of Amsterdam,undefined
[5] Amsterdam UMC Location University of Amsterdam,undefined
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
CT imaging under external valgus and varus loading conditions and consecutive image analysis can be used to detect tibial implant loosening after total knee arthroplasty. However, the applied load causes the tibia to deform, which could result in an overestimation of implant displacement. This research evaluates the extent of tibia deformation and its effect on measuring implant displacement. Ten cadaver specimen with TKA were CT-scanned under valgus/varus loading (20 Nm), first implanted without bone cement fixation (mimicking a loose implant) and subsequently with bone cement fixation (mimicking a fixed implant). By means of image analysis, three relative displacements were assessed: (1) between the proximal and distal tibia (measure of deformation), (2) between the implant and the whole tibia (including potential deformation effect) and (3) between the implant and the proximal tibia (reduced deformation effect). Relative displacements were quantified in terms of translations along, and rotations about the axes of a local coordinate system. As a measure of deformation, the proximal tibia moved relative to the distal tibia by, on average 1.27 mm (± 0.50 mm) and 0.64° (± 0.25°). Deformation caused an overestimation of implant displacement in the cemented implant. The implant displaced with respect to the whole tibia by 0.45 mm (± 0.22 mm) and 0.79° (± 0.38°). Relative to the proximal tibia, the implant moved by 0.23 mm (± 0.10 mm) and 0.62° (± 0.34°). The differentiation between loose and fixed implants improved when tibia deformation was compensated for by using the proximal tibia rather than the whole tibia.
引用
收藏
相关论文
共 50 条
  • [41] Effect of adipose-derived stem cells on bone healing on titanium implant in tibia of diabetes mellitus induced rats
    Kim, Min-Gu
    Jung, In-Kyo
    Shin, Sang-Hun
    Kim, Chul-Hoon
    Kim, Bok-Joo
    Kim, Jung-Han
    Hwang, Young-Sup
    Jung, Eu-Gene
    Kim, Jin-Woo
    Kim, Uk-Kyu
    [J]. JOURNAL OF THE KOREAN ASSOCIATION OF ORAL AND MAXILLOFACIAL SURGEONS, 2010, 36 (05) : 392 - 401
  • [42] Effect of low intensity pulsed ultrasound (LIPUS) on bone healing around a titanium implant in the tibia of osteoporosis-induced rats
    Hwang, Young-Seob
    Jeon, Hyun-Jun
    Shin, Sang-Hun
    Chung, In-Kyo
    Kim, Gyoo-Cheon
    Kim, Chul-Hoon
    Kim, Uk-Kyu
    [J]. JOURNAL OF THE KOREAN ASSOCIATION OF ORAL AND MAXILLOFACIAL SURGEONS, 2011, 37 (05) : 386 - 395
  • [43] Ramp wear induced contamination and its effect on load/unload performance
    Zhao, Q
    Talke, FE
    [J]. JOURNAL OF INFORMATION STORAGE AND PROCESSING SYSTEMS, 2001, 3 (3-4): : 207 - 212
  • [44] Numerical modeling of the load effect on PZT-induced guided wave for load compensation of damage detection
    Sun, Hu
    Zhang, Aijia
    Wang, Yishou
    Qing, Xinlin P.
    [J]. HEALTH MONITORING OF STRUCTURAL AND BIOLOGICAL SYSTEMS 2017, 2017, 10170
  • [45] Development of chloride-induced corrosion in pre-cracked RC beams under sustained loading: Effect of load-induced cracks, concrete cover, and exposure conditions
    Yu, Linwen
    Francois, Raoul
    Vu Hiep Dang
    L'Hostis, Valerie
    Gagne, Richard
    [J]. CEMENT AND CONCRETE RESEARCH, 2015, 67 : 246 - 258
  • [46] Iron load and its effect on oxidative stress and inflammation in rats with induced colitis
    Aghdassi, E
    Carrier, J
    Cullen, J
    Allard, JP
    [J]. GASTROENTEROLOGY, 1999, 116 (04) : A853 - A853
  • [47] Inhibition of T-Type Voltage Sensitive Calcium Channel Reduces Load-Induced OA in Mice and Suppresses the Catabolic Effect of Bone Mechanical Stress on Chondrocytes
    Srinivasan, Padma P.
    Parajuli, Ashutosh
    Price, Christopher
    Wang, Liyun
    Duncan, Randall L.
    Kirn-Safran, Catherine B.
    [J]. PLOS ONE, 2015, 10 (05):
  • [48] Flow-induced deformation of compliant microchannels and its effect on pressure–flow characteristics
    A. Raj
    A. K. Sen
    [J]. Microfluidics and Nanofluidics, 2016, 20
  • [49] Surface stress induced by interactions of adsorbates and its effect on deformation and frequency of microcantilever sensors
    Yi, X.
    Duan, H. L.
    [J]. JOURNAL OF THE MECHANICS AND PHYSICS OF SOLIDS, 2009, 57 (08) : 1254 - 1266
  • [50] DECREASED MICROFILARIAL LOAD AND ITS EFFECT ON THE CALCULATION OF PREVALENCE AND THE RATE OF FALSE NEGATIVES IN THE DETECTION OF ONCHOCERCIASIS
    MULLEN, K
    PROST, A
    [J]. INTERNATIONAL JOURNAL OF EPIDEMIOLOGY, 1983, 12 (01) : 102 - 104