Load-induced deformation of the tibia and its effect on implant loosening detection

被引:0
|
作者
M. A. ter Wee
J. G. G. Dobbe
G. S. Buijs
A. J. Kievit
M. U. Schafroth
M. Maas
L. Blankevoort
G. J. Streekstra
机构
[1] Amsterdam UMC Location University of Amsterdam,Department of Biomedical Engineering and Physics
[2] Amsterdam Movement Sciences,Department of Orthopedic Surgery and Sports Medicine
[3] Musculoskeletal Health,Department of Radiology
[4] Amsterdam UMC Location University of Amsterdam,undefined
[5] Amsterdam UMC Location University of Amsterdam,undefined
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
CT imaging under external valgus and varus loading conditions and consecutive image analysis can be used to detect tibial implant loosening after total knee arthroplasty. However, the applied load causes the tibia to deform, which could result in an overestimation of implant displacement. This research evaluates the extent of tibia deformation and its effect on measuring implant displacement. Ten cadaver specimen with TKA were CT-scanned under valgus/varus loading (20 Nm), first implanted without bone cement fixation (mimicking a loose implant) and subsequently with bone cement fixation (mimicking a fixed implant). By means of image analysis, three relative displacements were assessed: (1) between the proximal and distal tibia (measure of deformation), (2) between the implant and the whole tibia (including potential deformation effect) and (3) between the implant and the proximal tibia (reduced deformation effect). Relative displacements were quantified in terms of translations along, and rotations about the axes of a local coordinate system. As a measure of deformation, the proximal tibia moved relative to the distal tibia by, on average 1.27 mm (± 0.50 mm) and 0.64° (± 0.25°). Deformation caused an overestimation of implant displacement in the cemented implant. The implant displaced with respect to the whole tibia by 0.45 mm (± 0.22 mm) and 0.79° (± 0.38°). Relative to the proximal tibia, the implant moved by 0.23 mm (± 0.10 mm) and 0.62° (± 0.34°). The differentiation between loose and fixed implants improved when tibia deformation was compensated for by using the proximal tibia rather than the whole tibia.
引用
收藏
相关论文
共 50 条
  • [21] The effect of load-induced thermal strain on flat slab behaviour at elevated temperatures
    Al Hamd, Rwayda Kh S.
    Gillie, Martin
    Warren, Holly
    Torelli, Giacomo
    Stratford, Tim
    Wang, Yong
    [J]. FIRE SAFETY JOURNAL, 2018, 97 : 12 - 18
  • [22] Circadian rhythm effect on load-induced bone formation and gene expression in mice
    Bouchard, Alice
    Willie, Bettina
    Julien, Catherine
    Dsouza, Chrisanne
    [J]. JOURNAL OF BONE AND MINERAL RESEARCH, 2019, 34 : 213 - 213
  • [23] THE EFFECT OF A STIFF SPINAL IMPLANT AND ITS LOOSENING ON BONE-MINERAL CONTENT IN CANINES
    DALENBERG, DD
    ASHER, MA
    ROBINSON, RG
    JAYARAMAN, G
    [J]. SPINE, 1993, 18 (13) : 1862 - 1866
  • [24] Effect of accelerated carbonation conditions on the characterization of load-induced damage in reinforced concrete members
    Ghantous, Rita Maria
    Poyet, Stephane
    L'Hostis, Valerie
    Nhu-Cuong Tran
    Francois, Raoul
    [J]. MATERIALS AND STRUCTURES, 2017, 50 (03)
  • [25] Damage detection based on accelerometers and computer vision measurements of moving load-induced structural responses
    Wu, Tong
    Tang, Liang
    Zhou, Fengli
    Zhang, Yudan
    Zhou, Zhixiang
    [J]. MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2024, 211
  • [26] Deformation behavior of K0-consolidated soft clay under traffic load-induced stress paths
    Wu T.-Y.
    Guo L.
    Cai Y.-Q.
    Wang J.
    [J]. Yantu Gongcheng Xuebao/Chinese Journal of Geotechnical Engineering, 2017, 39 (05): : 859 - 867
  • [27] Effect of accelerated carbonation conditions on the characterization of load-induced damage in reinforced concrete members
    Rita Maria Ghantous
    Stéphane Poyet
    Valérie L’Hostis
    Nhu-Cuong Tran
    Raoul François
    [J]. Materials and Structures, 2017, 50
  • [28] Large-scale global surface mass variations inferred from GPS measurements of load-induced deformation
    Wu, XP
    Heflin, MB
    Ivins, ER
    Argus, DF
    Webb, FH
    [J]. GEOPHYSICAL RESEARCH LETTERS, 2003, 30 (14)
  • [29] Analyzing typhoon-triggered vertical land motion from GPS and environmental load-induced deformation data
    Yao ChaoLong
    Liu LiLong
    Lin Xu
    Wang ChangWei
    Zhang Rui
    Wang JianFang
    Chen RongQi
    [J]. CHINESE JOURNAL OF GEOPHYSICS-CHINESE EDITION, 2020, 63 (08): : 2870 - 2881
  • [30] Mechanical Load-Induced Atomic-Scale Deformation Evolution and Mechanism of SiC Polytypes Using Molecular Dynamics Simulation
    Wang, Haoxiang
    Gao, Shang
    Kang, Renke
    Guo, Xiaoguang
    Li, Honggang
    [J]. NANOMATERIALS, 2022, 12 (14)