Clinical and radiographic results and wear performance in different generations of a cementless porous-coated acetabular cup

被引:0
|
作者
E. García-Rey
E. García-Cimbrelo
机构
[1] Hospital La Paz,Department of Orthopaedics
来源
关键词
Femoral Head; Acetabular Component; Polyethylene Wear; Polyethylene Liner; Metal Shell;
D O I
暂无
中图分类号
学科分类号
摘要
We compared clinical results and wear performance in two different generations of a cementless porous-coated cup, analysing the long-term results of 83 uncemented Harris-Galante I cups (32-mm femoral head) and 93 uncemented Harris-Galante II cups (28-mm femoral head). All polyethylene liners were gamma irradiated in air. Polyethylene linear wear was estimated using a software package. The minimum follow-up was 10 years. Nine Harris-Galante I cups and two Harris-Galante II cups were revised due to aseptic loosening or polyethylene problems. The mean femoral head penetration at 6 weeks after surgery was 0.15 ± 0.05 mm for the Harris-Galante I cups and 0.12 ± 0.03 for the Harris-Galante II cups (p < 0.001);but mean wear was 0.13 ± 0.23 mm per year for the Harris-Galante I cups and 0.11 ± 0.10 for the Harris-Galante II cups (p = 0.740). Most of the metallic shells in both groups showed stable fixation. The so-called second-generation cups had lower initial polyethylene wear that resulted in less polyethylene wear at the latest the follow-up, but the overall wear rate was similar in both groups despite the different femoral head sizes and the improved locking mechanism.
引用
收藏
页码:181 / 187
页数:6
相关论文
共 50 条
  • [31] Results of the Novation Crowncup™ porous-coated uncemented acetabular component in total hip arthroplasty: a 10-year clinical and radiological assessment
    Godoy-Monzon, Daniel
    Garcia-Mansilla, Agustin
    Casteulani, Alberto Cid
    Svarzchtein, Santiago
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2021, 55 (04) : 311 - 315
  • [32] Acetabular reconstruction using a cementless cup and hydroxyapatite granules - 3- to 8-year clinical results
    Sudo, Akihiro
    Hasegawa, Masahiro
    Fukuda, Aki
    Kawamura, Goshin
    Muraki, Makoto
    Uchida, Atsumasa
    JOURNAL OF ARTHROPLASTY, 2007, 22 (06): : 828 - 832
  • [33] Influence of Stem Size on Clinical Outcome of Primary Total Hip Arthroplasty with Cementless Extensively Porous-Coated Femoral Components
    Engh, C. Anderson, Jr.
    Mohan, Vivek
    Nagowski, Jarrod P.
    Terefenko, Christi J. Sychterz
    Engh, Charles A.
    JOURNAL OF ARTHROPLASTY, 2009, 24 (04): : 554 - 559
  • [34] Ten-year results with the Morscher press-fit cup: an uncemented, non-modular, porous-coated cup inserted without screws
    Garavaglia, Guido
    Luebbeke, Anne
    Barea, Christophe
    Roussos, Constantinos
    Peter, Robin
    Hoffmeyer, Pierre
    INTERNATIONAL ORTHOPAEDICS, 2011, 35 (07) : 957 - 963
  • [35] THE HARRIS-GALANTE POROUS-COATED ACETABULAR COMPONENT WITH SCREW FIXATION - RADIOGRAPHIC ANALYSIS OF 83 PRIMARY HIP REPLACEMENTS AT A MINIMUM OF 5 YEARS
    SCHMALZRIED, TP
    HARRIS, WH
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1992, 74A (08): : 1130 - 1139
  • [36] Ten-year results with the Morscher press-fit cup: an uncemented, non-modular, porous-coated cup inserted without screws
    Guido Garavaglia
    Anne Lübbeke
    Christophe Barea
    Constantinos Roussos
    Robin Peter
    Pierre Hoffmeyer
    International Orthopaedics, 2011, 35 : 957 - 963
  • [37] THE CLINICAL-RESULTS AND BASIC SCIENCE OF TOTAL HIP-ARTHROPLASTY WITH POROUS-COATED PROSTHESES
    CALLAGHAN, JJ
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1993, 75A (02): : 299 - 310
  • [38] Cemented polyethylene and cementless porous-coated acetabular components have similar outcomes at a mean of seven years after total hip replacement A PROSPECTIVE RANDOMISED STUDY
    Angadi, D. S.
    Brown, S.
    Crawfurd, E. J. P.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2012, 94B (12): : 1604 - 1610
  • [39] Mid-term clinical and radiographic outcomes of porous-coated metaphyseal sleeves used in revision total knee arthroplasty
    Gurel, Ron
    Morgan, Samuel
    Elbaz, Etay
    Ashlenazi, Itay
    Snir, Nimrod
    Kadar, Assaf
    Gold, Aviram
    Warschawski, Yaniv
    KNEE SURGERY & RELATED RESEARCH, 2021, 33 (01)
  • [40] Mid-term clinical and radiographic outcomes of porous-coated metaphyseal sleeves used in revision total knee arthroplasty
    Ron Gurel
    Samuel Morgan
    Etay Elbaz
    Itay Ashlenazi
    Nimrod Snir
    Assaf Kadar
    Aviram Gold
    Yaniv Warschawski
    Knee Surgery & Related Research, 33