Clinical and radiographic results and wear performance in different generations of a cementless porous-coated acetabular cup

被引:0
|
作者
E. García-Rey
E. García-Cimbrelo
机构
[1] Hospital La Paz,Department of Orthopaedics
来源
International Orthopaedics | 2008年 / 32卷
关键词
Femoral Head; Acetabular Component; Polyethylene Wear; Polyethylene Liner; Metal Shell;
D O I
暂无
中图分类号
学科分类号
摘要
We compared clinical results and wear performance in two different generations of a cementless porous-coated cup, analysing the long-term results of 83 uncemented Harris-Galante I cups (32-mm femoral head) and 93 uncemented Harris-Galante II cups (28-mm femoral head). All polyethylene liners were gamma irradiated in air. Polyethylene linear wear was estimated using a software package. The minimum follow-up was 10 years. Nine Harris-Galante I cups and two Harris-Galante II cups were revised due to aseptic loosening or polyethylene problems. The mean femoral head penetration at 6 weeks after surgery was 0.15 ± 0.05 mm for the Harris-Galante I cups and 0.12 ± 0.03 for the Harris-Galante II cups (p < 0.001);but mean wear was 0.13 ± 0.23 mm per year for the Harris-Galante I cups and 0.11 ± 0.10 for the Harris-Galante II cups (p = 0.740). Most of the metallic shells in both groups showed stable fixation. The so-called second-generation cups had lower initial polyethylene wear that resulted in less polyethylene wear at the latest the follow-up, but the overall wear rate was similar in both groups despite the different femoral head sizes and the improved locking mechanism.
引用
收藏
页码:181 / 187
页数:6
相关论文
共 50 条
  • [41] Cementless acetabular component St. Nabor. clinical and radiographic results after medium term follow-up.
    Kirschner, P
    Kreutz, A
    ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 2000, 138 (04): : 306 - 310
  • [42] POROUS-COATED HIP-REPLACEMENT - THE FACTORS GOVERNING BONE INGROWTH, STRESS SHIELDING, AND CLINICAL-RESULTS
    ENGH, CA
    BOBYN, JD
    GLASSMAN, AH
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1987, 69 (01): : 45 - 55
  • [43] Clinical experience with a proximally porous-coated second-generation cementless total hip prosthesis - Minimum 5-year follow-up
    Mont, MA
    Yoon, TR
    Krackow, KA
    Hungerford, DS
    JOURNAL OF ARTHROPLASTY, 1999, 14 (08): : 930 - 939
  • [44] Primary total hip arthroplasty with a cementless porous-coated anatomic total hip prosthesis - 10-to 12-year results of prospective and consecutive series
    Kim, YH
    Kim, JS
    Cho, SH
    JOURNAL OF ARTHROPLASTY, 1999, 14 (05): : 538 - 548
  • [45] Evaluation of a porous tantalum uncemented acetabular cup in revision total hip arthroplasty - Clinical and radiological results of 60 hips
    Unger, AS
    Lewis, RJ
    Gruen, T
    JOURNAL OF ARTHROPLASTY, 2005, 20 (08): : 1002 - 1009
  • [46] Midterm Results of a Contemporary, Porous-Coated Acetabular System in Patients Undergoing Primary Total Hip Replacement for Degenerative Hip Disease: A Prospective, Multicenter Study
    Wilson, Ian R.
    Turgeon, Thomas R.
    Gascoyne, Trevor C.
    Della Valle, Craig J.
    McCalden, Richard W.
    JOURNAL OF ARTHROPLASTY, 2020, 35 (07): : 1862 - 1867
  • [47] Porous tantalum uncemented acetabular shells in revision total hip replacement: two to four year clinical and radiographic results
    Kim, W. Y.
    Greidanus, N. V.
    Duncan, C. P.
    Masri, B. A.
    Garbuz, D. S.
    HIP INTERNATIONAL, 2008, 18 (01) : 17 - 22
  • [48] Clinical results of the modular porous-coated anatomic (PCA) total knee arthroplasty with cement: A 5-year prospective study
    Knight, JL
    Atwater, RD
    Grothaus, L
    ORTHOPEDICS, 1997, 20 (11) : 1025 - 1033
  • [49] Isolated revision acetabuloplasty using a porous-coated cementless acetabular component without removal of a well-fixed femoral component - A 3- to 9-year follow-up study
    Moskal, JT
    Danisa, OA
    Shaffrey, CI
    JOURNAL OF ARTHROPLASTY, 1997, 12 (07): : 719 - 727
  • [50] Clinical Performance, Patient Reported Outcome, and Radiological Results of a Short, Tapered, Porous, Proximally Coated Cementless Femoral Stem: Results up to Seven Years of Follow-Up
    Ulivi, Michele
    Orlandini, Luca C.
    Meroni, Valentina
    Lombardo, Michele D. M.
    Peretti, Giuseppe M.
    JOURNAL OF ARTHROPLASTY, 2018, 33 (04): : 1133 - 1138