Ten-year results with the Morscher press-fit cup: an uncemented, non-modular, porous-coated cup inserted without screws

被引:14
|
作者
Garavaglia, Guido [1 ,2 ]
Luebbeke, Anne [1 ]
Barea, Christophe [1 ]
Roussos, Constantinos [1 ]
Peter, Robin [1 ]
Hoffmeyer, Pierre [1 ]
机构
[1] Univ Hosp Geneva, Div Orthopaed & Trauma Surg, CH-1211 Geneva 14, Switzerland
[2] ORBV, Orthopaed Surg Serv, Bellinzona, Switzerland
关键词
TOTAL HIP-ARTHROPLASTY; FOLLOW-UP; ACETABULAR COMPONENT; POLYETHYLENE WEAR; FEMORAL COMPONENT; REPLACEMENT; CEMENT; FIXATION; OSTEOLYSIS; SOCKETS;
D O I
10.1007/s00264-010-1059-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Total hip arthroplasty (THA) with well designed cementless acetabular implants has shown excellent results. The purpose of this study was to assess our clinical and radiological outcomes using an uncemented cup. We conducted a prospective cohort study including all consecutive primary THAs performed with the Morscher press-fit cup, an uncemented non-modular acetabular component, between March 1996 and December 1998. Patients were evaluated at ten years with clinical and radiological follow-up, patient satisfaction and questionnaire assessment using the Harris hip score (HHS), Merle d'Aubign, and Postel score, the UCLA score, the 12-item short-form health survey (SF-12) and a visual analog scale. Five hundred sixty-one THAs were performed in 518 patients. At 120 months (+/- 7.3 months), 303 patients with 335 THAs were still available for follow-up. None of the patients had required cup revision for aseptic loosening. At ten years, the cup survivorship was 98.8% (95% CI 97.4-99.5) with cup revision for any cause as an endpoint. No radiolucencies were seen around the cups, but osteolytic defects involved 21 stems (8.3%). Mean total linear polyethylene wear was 0.9 mm. The Morscher acetabular replacement cup provides excellent results at ten years. There were no revisions for aseptic loosening of the cup, and no osteolytic defects were found around the cup. Patient satisfaction was high and the clinical results were very good.
引用
收藏
页码:957 / 963
页数:7
相关论文
共 7 条
  • [1] Ten-year results with the Morscher press-fit cup: an uncemented, non-modular, porous-coated cup inserted without screws
    Guido Garavaglia
    Anne Lübbeke
    Christophe Barea
    Constantinos Roussos
    Robin Peter
    Pierre Hoffmeyer
    International Orthopaedics, 2011, 35 : 957 - 963
  • [2] Ten-year results of a press-fit, porous-coated acetabular component
    Grobler, GP
    Learmonth, ID
    Bernstein, BP
    Dower, BJ
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2005, 87B (06): : 786 - 789
  • [3] Cementless hemispheric porous-coated sockets implanted with press-fit technique without screws: Average ten-year follow-up
    Udomkiat, P
    Dorr, LD
    Wan, ZN
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A (07): : 1195 - 1200
  • [4] 10-year results of the uncemented Allofit press-fit cup in young patients
    Streit, Marcus R.
    Weiss, Stefan
    Andreas, Franziska
    Bruckner, Thomas
    Walker, Tilman
    Kretzer, J. Philippe
    Ewerbeck, Volker
    Merle, Christian
    ACTA ORTHOPAEDICA, 2014, 85 (04) : 368 - 374
  • [5] Computed Tomography Assessment of Pelvic Osteolysis and Cup-Lesion Interface Involvement with a Press-Fit Porous-Coated Acetabular Cup
    Egawa, Hiroshi
    Ho, Henry
    Hopper, Robert H., Jr.
    Engh, C. Anderson, Jr.
    Engh, Charles A.
    JOURNAL OF ARTHROPLASTY, 2009, 24 (02): : 233 - 239
  • [6] Quantitative Computed Tomography-Assisted Osteodensitometry of the Pelvis After Press-Fit Cup Fixation A Prospective Ten-Year Follow-up
    Kress, Alexander M.
    Schmidt, Rainer
    Vogel, Tobias
    Nowak, Tobias E.
    Forst, Raimund
    Mueller, Lutz A.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2011, 93A (12): : 1152 - 1157
  • [7] Cementless porous-coated sockets without holes implanted with pure press-fit technique - Average 6-year follow-up
    Spak, RT
    Stuchin, SA
    JOURNAL OF ARTHROPLASTY, 2005, 20 (01): : 4 - 10