Submillisievert imaging protocol using full reconstruction and advanced patient motion correction in 320-row area detector coronary CT angiography

被引:0
|
作者
Yuko Kawaguchi
Shinichiro Fujimoto
Kazuhisa Takamura
Etsuro Kato
Shoko Suda
Rie Matsumori
Makoto Hiki
Kanako K. Kumamaru
Hiroyuki Daida
机构
[1] Juntendo University Graduate School of Medicine,Department of Cardiovascular Medicine
[2] Juntendo University Graduate School of Medicine,Department of Radiology
关键词
320-row area detector coronary computed tomography angiography; Full reconstruction; Advanced patient motion correction; Radiation dosing; Submillisievert;
D O I
暂无
中图分类号
学科分类号
摘要
Radiation exposure remains a concern in the use of coronary CT angiography (CCTA). Full reconstruction (Full) and reconstruction using advanced patient motion correction (APMC) could obtain a lower radiation dose using low tube current scanning in a 320-row Area Detector CT (320-ADCT). The radiation dose for an imaging protocol using Full and APMC in daily practice was estimated. A total of 209 patients who underwent CCTA in 1 rotation scanning with 100 kv and adaptive iterative dose reduction 3D in 320-ADCT were enrolled. Imaging protocols were classified into 3 groups based on estimated slow filling time: (1) slow filling time ≥ 275 msec, Full with 30% of usual tube current (N = 43)(Full30%mA) (2) 206.3 msec ≤ slow filling time < 275 msec, APMC with 50% of usual tube current (N = 48)(APMC50%mA); and (3) 137.5 msec ≤ slow filling time < 206.3 msec, Half reconstruction with usual tube current (N = 118)(Half100%mA). Radiation dose was estimated by the effective dose. The diagnostic accuracy of CCTA was compared with that of invasive coronary angiography in 28 patients. The effective doses of Full30%mA, APMC50%mA, and Half100%mA were 0.77 ± 0.31, 1.30 ± 0.85, and 1.98 ± 0.68, respectively. Of 28 patients, the sensitivity, specificity, accuracy, positive predictive value, and negative predictive value in vessel-based analyses were: Full30%mA, 66.7, 82.4, 80.0, 40.0, and 93.3%; APMC50%mA, 100.0, 80.0, 83.3, 50.05, and 100.0%; and Half100%mA, 90.9, 83.0, 86.3, 78.95, and 92.9%, respectively. An imaging protocol using Full30%mA and APMC50%mA was one of the methods how radiation dose could be reduced radiation dose maintained diagnostic accuracy compared to imaging using conventional Half100%mA.
引用
收藏
页码:465 / 474
页数:9
相关论文
共 50 条
  • [31] Computed tomography angiography of carotid and coronary artery via a single-bolus injection protocol: a feasibility study using 320-row multidetector CT
    WeiGuo Zhang
    Hang Jin
    Gang Chen
    Wenfang Chen
    Junying Gu
    Mengsu Zeng
    European Radiology, 2014, 24 : 1628 - 1635
  • [32] Computed tomography angiography of carotid and coronary artery via a single-bolus injection protocol: a feasibility study using 320-row multidetector CT
    Zhang, WeiGuo
    Jin, Hang
    Chen, Gang
    Chen, Wenfang
    Gu, Junying
    Zeng, Mengsu
    EUROPEAN RADIOLOGY, 2014, 24 (07) : 1628 - 1635
  • [33] Feasibility of coronary calcium and stent image subtraction using 320-detector row CT angiography
    Fuchs, Andreas
    Kuhl, J. Tobias
    Chen, Marcus Y.
    Helquist, Steffen
    Razeto, Marco
    Arakita, Kazumasa
    Steveson, Chloe
    Arai, Andrew E.
    Kofoed, Klaus F.
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2015, 9 (05) : 393 - 398
  • [34] Adaptive Iterative Dose Reduction in coronary CT angiography using 320-row CT: Assessment of radiation dose reduction and image quality
    Tomizawa, Nobuo
    Nojo, Takeshi
    Akahane, Masaaki
    Torigoe, Rumiko
    Kiryu, Shigeru
    Ohtomo, Kuni
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2012, 6 (05) : 318 - 324
  • [35] Low contrast and radiation dose coronary CT angiography using a 320-row system and a refined contrast injection and timing method
    Oda, Seitaro
    Utsunomiya, Daisuke
    Yuki, Hideaki
    Kai, Noriyuki
    Hatemura, Masahiro
    Funama, Yoshinori
    Kidoh, Masafumi
    Yoshida, Morikatsu
    Namimoto, Tomohiro
    Yamashita, Yasuyuki
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2015, 9 (01) : 19 - 27
  • [36] Patient-related factors influencing detectability of coronary arteries in 320-row CT angiography in infants with complex congenital heart disease
    Yamasaki, Yuzo
    Kawanami, Satoshi
    Kamitani, Takeshi
    Sagiyama, Koji
    Shin, Seitaro
    Hino, Takuya
    Nagata, Hazumu
    Yabuuchi, Hidetake
    Nagao, Michinobu
    Honda, Hiroshi
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2018, 34 (09): : 1485 - 1491
  • [37] Patient-related factors influencing detectability of coronary arteries in 320-row CT angiography in infants with complex congenital heart disease
    Yuzo Yamasaki
    Satoshi Kawanami
    Takeshi Kamitani
    Koji Sagiyama
    Seitaro Shin
    Takuya Hino
    Hazumu Nagata
    Hidetake Yabuuchi
    Michinobu Nagao
    Hiroshi Honda
    The International Journal of Cardiovascular Imaging, 2018, 34 : 1485 - 1491
  • [38] Image quality and radiation reduction of 320-row area detector CT coronary angiography with optimal tube voltage selection and an automatic exposure control system: comparison with body mass index-adapted protocol
    Jiyeon Lim
    Eun-Ah Park
    Whal Lee
    Hackjoon Shim
    Jin Wook Chung
    The International Journal of Cardiovascular Imaging, 2015, 31 : 23 - 30
  • [39] Image quality and radiation reduction of 320-row area detector CT coronary angiography with optimal tube voltage selection and an automatic exposure control system: comparison with body mass index-adapted protocol
    Lim, Jiyeon
    Park, Eun-Ah
    Lee, Whal
    Shim, Hackjoon
    Chung, Jin Wook
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2015, 31 : 23 - 30
  • [40] Combined Adenosine Stress Perfusion and Coronary Angiography Using 320-Row Detector Dynamic Volume Computed Tomography in Patients with Suspected Coronary Artery Disease
    George, Richard T.
    Kitagawa, Kakuya
    Laws, Katherine
    Lardo, Albert C.
    Lima, Joao A.
    CIRCULATION, 2008, 118 (18) : S936 - S936