Effect of surface coating on the screw loosening of dental abutment screws

被引:0
|
作者
Chan-Ik Park
Han-Cheol Choe
Chae-Heon Chung
机构
[1] Chosun University,Department of Prosthodontics, College of Dentistry
[2] Chosun University,Department of Dental Materials & Research Center of Nano
来源
关键词
screw loosening; screw surface treatment; coated screw; scratch test;
D O I
暂无
中图分类号
学科分类号
摘要
Regardless of the type of performed restoration, in most cases, a screw connection is employed between the abutment and implant. For this reason, implant screw loosening has remained a problem in restorative practices. The purpose of this study was to compare the surface of coated/plated screws with titanium and gold alloy screws and to evaluate the physical properties of coated/plated material after scratch tests via FE-SEM (field emission scanning electron microscopy) investigation. GoldTite, titanium screws provided by 3i (Implant Innovation, USA) and TorqTite, titanium screws by Steri-Oss (Nobel Biocare, USA) and gold screws and titanium screws by AVANA (Osstem Implant, Korea) were selected for this study. The surface, crest, and root of the abutment screws were observed by FE-SEM. A micro-diamond needle was also prepared for the scratch test. Each abutment screw was fixed, and a scratch on the surface of the head region was made at constant load and thereafter the fine trace was observed with FE-SEM. The surface of GoldTite was smoother than that of other screws and it also had abundant ductility and malleability compared with titanium and gold screws. The scratch tests also revealed that teflon particles were exfoliated easily in the screw coated with teflon. The titanium screw had rough surface and low ductility. The clinical use of gold-plated screws is recommended as a means of preventing screw loosening.
引用
收藏
页码:549 / 553
页数:4
相关论文
共 50 条
  • [31] Influence of the difference between implant body and screw materials on abutment screw loosening
    Shinohara, Ryusuke
    Ueda, Kazuhiko
    Watanabe, Fumihiko
    DENTAL MATERIALS JOURNAL, 2019, 38 (01) : 150 - 156
  • [32] Effect of lateral cyclic loading on abutment screw loosening of an external hexagon implant system
    Khraisat, A
    Hashimoto, A
    Nomura, S
    Miyakawa, O
    JOURNAL OF PROSTHETIC DENTISTRY, 2004, 91 (04): : 326 - 334
  • [33] Does Abutment Collar Length Affect Abutment Screw Loosening After Cyclic Loading?
    Siadat, Hakimeh
    Pirmoazen, Salma
    Beyabanaki, Elaheh
    Alikhasi, Marzieh
    JOURNAL OF ORAL IMPLANTOLOGY, 2015, 41 : 346 - 351
  • [34] The influence of implant-abutment connection on the screw loosening and microleakage
    Tsuruta, Katsuhiro
    Ayukawa, Yasunori
    Matsuzaki, Tatsuya
    Kihara, Masafumi
    Koyano, Kiyoshi
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2018, 4
  • [35] Mechanism of and factors associated with the loosening of the implant abutment screw: A review
    Huang, Yiqing
    Wang, Jiawei
    JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2019, 31 (04) : 338 - 345
  • [36] The Influence of Abutment Angulation on Screw Loosening of Implants in the Anterior Maxilla
    Ha, Chun-Yeo
    Lim, Yung-Jun
    Kim, Myung-Joo
    Choi, Jung-Han
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2011, 26 (01) : 45 - 55
  • [37] Coating Materials to Prevent Screw Loosening in Single Dental Implant Crowns: A Systematic Review
    Coelho, Lara
    Manzanares-Cespedes, Maria-Cristina
    Mendes, Joana
    Tallon-Walton, Victoria
    Astudillo-Rozas, Wilson
    Aroso, Carlos
    Mendes, Jose Manuel
    MATERIALS, 2024, 17 (20)
  • [38] Coating Materials to Prevent Screw Loosening in Single Dental Implant Crowns: A Systematic Review
    Coelho, Lara
    Manzanares-Céspedes, Maria-Cristina
    Mendes, Joana
    Tallón-Walton, Victòria
    Astudillo-Rozas, Wilson
    Aroso, Carlos
    Mendes, José Manuel
    Materials, 17 (20):
  • [39] Comparative study of abutment screw loosening with or without adhesive material
    Arshad, Mahnaz
    Shirani, Gholamreza
    Refoua, Sina
    Yeganeh, Mohammadreza Rahimi
    JOURNAL OF ADVANCED PROSTHODONTICS, 2017, 9 (02): : 99 - 103
  • [40] The Effect of Screw Length on Fracture Load and Abutment Strain in Dental Implants with External Abutment Connections
    Kim, Byung-Jun
    Yeo, In-Sung
    Lee, Joo-Hee
    Kim, Seong-Kyun
    Heo, Seong-Joo
    Koak, Jai-Young
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2012, 27 (04) : 820 - 823