Effect of surface coating on the screw loosening of dental abutment screws

被引:0
|
作者
Chan-Ik Park
Han-Cheol Choe
Chae-Heon Chung
机构
[1] Chosun University,Department of Prosthodontics, College of Dentistry
[2] Chosun University,Department of Dental Materials & Research Center of Nano
来源
关键词
screw loosening; screw surface treatment; coated screw; scratch test;
D O I
暂无
中图分类号
学科分类号
摘要
Regardless of the type of performed restoration, in most cases, a screw connection is employed between the abutment and implant. For this reason, implant screw loosening has remained a problem in restorative practices. The purpose of this study was to compare the surface of coated/plated screws with titanium and gold alloy screws and to evaluate the physical properties of coated/plated material after scratch tests via FE-SEM (field emission scanning electron microscopy) investigation. GoldTite, titanium screws provided by 3i (Implant Innovation, USA) and TorqTite, titanium screws by Steri-Oss (Nobel Biocare, USA) and gold screws and titanium screws by AVANA (Osstem Implant, Korea) were selected for this study. The surface, crest, and root of the abutment screws were observed by FE-SEM. A micro-diamond needle was also prepared for the scratch test. Each abutment screw was fixed, and a scratch on the surface of the head region was made at constant load and thereafter the fine trace was observed with FE-SEM. The surface of GoldTite was smoother than that of other screws and it also had abundant ductility and malleability compared with titanium and gold screws. The scratch tests also revealed that teflon particles were exfoliated easily in the screw coated with teflon. The titanium screw had rough surface and low ductility. The clinical use of gold-plated screws is recommended as a means of preventing screw loosening.
引用
收藏
页码:549 / 553
页数:4
相关论文
共 50 条
  • [21] Influence of the coating material on the loosing of dental implant abutment screw joints
    Elias, C. N.
    Figueira, D. C.
    Rios, P. R.
    MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC AND SUPRAMOLECULAR SYSTEMS, 2006, 26 (08): : 1361 - 1366
  • [22] Abutment screw loosening of endosseous dental implant body/abutment joint by cyclic torsional loading test at the initial stage
    Katsuta, Yasuhiro
    Watanabe, Fumihiko
    DENTAL MATERIALS JOURNAL, 2015, 34 (06) : 896 - 902
  • [23] Carbon Film Coating of Abutment Surfaces: Effect on the Abutment Screw Removal Torque
    Corazza, Pedro Henrique
    Silva, Alecsandro de Moura
    Cavalcanti Queiroz, Jose Renato
    Salazar Marocho, Susana Maria
    Bottino, Marco Antonia
    Massi, Marcos
    de Assuncao e Souza, Rodrigo Othavio
    IMPLANT DENTISTRY, 2014, 23 (04) : 434 - 438
  • [24] Evaluation the loosening of abutment screws in fluid contamination: an in vitro study
    Fei Sun
    Wei Cheng
    Bao-hong Zhao
    Gui-Qiu Song
    Zeng Lin
    Scientific Reports, 12
  • [25] Study of screw loosening in cementation type implant abutment
    Hwang, BY
    Kim, YS
    JOURNAL OF DENTAL RESEARCH, 2000, 79 (05) : 1267 - 1267
  • [26] The influence of implant–abutment connection on the screw loosening and microleakage
    Katsuhiro Tsuruta
    Yasunori Ayukawa
    Tatsuya Matsuzaki
    Masafumi Kihara
    Kiyoshi Koyano
    International Journal of Implant Dentistry, 4
  • [27] Effect of platform design of dental implant abutment on loosening and fatigue performance
    Sun, Fei
    Xu, Li-Bing
    Lai, Song-Xian
    Xu, Hai
    Li, Xin-Chang
    Lin, Zeng
    ENGINEERING FAILURE ANALYSIS, 2025, 168
  • [28] Evaluation the loosening of abutment screws in fluid contamination: an in vitro study
    Sun, Fei
    Cheng, Wei
    Zhao, Bao-hong
    Song, Gui-Qiu
    Lin, Zeng
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [29] Study of Screw Loosening in Abutment Subject to Occlusal Loading
    Cheng, E-Hsung
    Lin, Ming-Jer
    Shiu, Sheng-Yan
    Tsai, Tung-Lin
    Chen, Yi-Chin
    ADVANCED MATERIALS, PTS 1-3, 2012, 415-417 : 2166 - 2171
  • [30] Implant Abutment Screw Loosening: A Review of Effective Factors
    Seddigh, Mohammad Ali
    Mostafavi, Azam Sadat
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2019, 13 (08) : ZE6 - ZE9